ARC WELDING MACHINE Скачать руководство пользователя страница 2

8

green wire of the mains cable is connected to the earth plug
pin.

 The capacity of magnetothermic switch or fuses in series

with  mains supply should be equal to current  I

1

 absorbed

by the unit.

 Input current I

1

 is  determined by  reading the techinical

specifications on  unit  i.e. power supply voltage U

1

available.

 Any   extensions  should  have  adequate  sections   for input

current I

1

.

 Turn machine on with switch (

8

) fig.2.

WARNING: ELECTRIC SHOCK CAN KILL.

 Do not touch live electric parts.

 Do  not  touch weld output  terminals  when  unit  is

energized.

 Do not touch torch or electrode holder and earth  clamp at

the same time.

 Regulate  current based on the diameter of  the  electrode,

welding  position and type of joint to be  carried  out. When
finished welding, always remember to turn unit off, and to
remove electrode from electrode holder.

3.5  TIG WELDING

 This  welding  machine is fit for  welding  with  TIG

procedure: stainless steel, iron, and copper.

 Connect  earth  cable wire to positive  (+)  pole  of welding

machine and terminal to working piece as  close as  possible
to welding machine, making sure there is  a good electrical
contact.

 Use  T150 torch (item 1567.01) and connect  power  wire

(

2

) fig.3 to negative pole (-) of welding machine.

 The welding machine circuit should not be deliberately in

direct or indirect contact with protection  conductor if not in
the workpiece.

 If earthing is deliberately made on the workpiece by  means

of protection wire, the connection must be as direct  as
possible, with the wire having a section at least  equal to the
welding return current  wire and connected to the piece
being worked  on, in the same place as the return wire,  using
the  return  wire terminal or a  second  earth  terminal closeby.

 All  possible precautions must be taken in  order  to avoid

stray currents.

 Connect gas pipe  (

4

) to pressure reducer  output connec-

ted to an ARGON cylinder.

 Press torch push-button and regulate gas capacity.

 There  is a valve inside the torch handle   which blocks the

gas, upon releasing the  push-button.

 Use a 2% thoriated tungsten electrode chosen according

to  table 2 and prepared according to that indicated  in point
3.5.1.

3.3 GENERAL NOTES

Before  using this welding machine, carefully  read  the
CENELEC standards HD 407 and  HD  433  also  check
insulation  of   cables, electrode  holder clamp, sockets and
plugs and that  the section and length of welding cables are
compatible with current used.

Up to 5 mt. use 16 mm

2

From 5 to 20 mt, use 25 mm

2

From 20 to 30 mt. use 35 mm

2

3.4  COATED ELECTRODE WELDING

 This  welding  machine is fit to weld  all  types  of electrodes

except the cellulose type (AWS 6010)

 Use electrode holder clamps in compliance  with  the safety

standards  and  without  projecting   tightening screws.

 Make sure that switch (

F

) fig. 2 is in 0 position or not

inserted in supply socket then  connect  welding cables  in
accordance  with polarity  demanded  by  the electrode
manufacturer which you will be using.
Connect the earth cable clamp to the workpiece.
VERY IMPORTANT: To secure a proper working of this
machine and to avoid current drops make sure that the
clamp seals with the workpiece.

 Welding  circuit  should not be deliberately  placed  in direct

or indirect contact with protection wire if  not in the workpiece.

 If earthing is deliberately made on the workpiece by  means

of protection wire, the connection must be as direct  as
possible,  with the wire having a section at least  equal to the
welding return current  wire and connected to the piece being
worked on, in the same place as the return  wire, using  the
return wire terminal or a second earth terminal
closeby.

 All  possible precautions must be taken in  order  to avoid

stray currents.

 Check to see that power supply voltage corresponds to

voltage indicated on the welding machine technical
specification tag.

 Connect  supply cable (

G

) fig.2:  When mounting a plug,

make sure that its capacity is adeguate and that the yellow-

Fig. 2

Fig. 3

Содержание WELDING MACHINE

Страница 1: ... for welding with coated electrodes U0 Secondary no load voltage Peak value X Duty cycle percentage The duty cycle expresses the percentage of 10 minutes in which the welding machine can operate at a determined current without over heating I2 Welding current U2 Secondary voltage with welding current I2 U1 Rated supply voltage 1 50 60Hz Single phase supply 50 or 60 Hz I1 Input current at the corres...

Страница 2: ...N cylinder Press torch push button and regulate gas capacity There is a valve inside the torch handle which blocks the gas upon releasing the push button Use a 2 thoriated tungsten electrode chosen according to table 2 and prepared according to that indicated in point 3 5 1 3 3 GENERAL NOTES Before using this welding machine carefully read the CENELEC standards HD 407 and HD 433 also check insulat...

Страница 3: ...urce and remove input power plug from receptacle before maintenace servicing MOVING PARTS can cause serious injury Keep away from moving parts HOT SURFACES can cause severe burns Allow cooling the unit before servicing 4 2 WELDING MACHINE MAINTENANCE Experience has shown that many fatal accidents originated from servicing which had not been perfectly executed For this reason a careful and thorough...

Страница 4: ...ospherescontainingeven minute amounts of trichloroethylene or perchloroethylene 5 4 Explosions Do not weld above or near containers under pressure Do not weld in environments containing explosive dusts gases or vapours This welding machine is used for TIG welding and uses ARGON gas for the protection of the arc thus you should take special precautions A CYLINDERS NEVER DEFACE or alter name number ...

Страница 5: ...nnect power supply cable from mains before replacing cables or before removing unit covers Do not use the unit without protection covers Always replace any damaged parts of the unit with original material Never remove unit safety devices Make sure that the power supply line is equipped with an efficient earth plug Any maintenance should only be carried out by qualified personnel aware of the risks...

Отзывы: