background image

PHOTO BEAM

PRESS AND HOLD 

P

IT DISPLAYS “

P1

”, PRESS      ONCE, IT DISPLAYS 

P2

”, PRESS

AGAIN TO SHOW THE CURRENT SITUATION. PRESS 

TO INCREASE THE FORCE ONE DEGREE AND PRESS      TO DECREASE 

ONE DEGREE. MAXIMUM DEGREE IS “

F9

”  AND MINIMUM IS “

F1”.

PRESS 

TO CONFIRM. THE DEFAULT SETTING IS 

“F5”

PRESS AND HOLD 

P

, IT DISPLAYS “

P1

”, PRESS     TWICE, IT DISPLAYS 

“P3”.

PRESS 

P

TO SHOW CURRENT SITUATION. PRESS      ONCE, IT DISPLAYS 

H1

, THE PHOTO BEAM IS ENABLED. PRESS      ONCE, IT DISPLAYS 

“H0”,

THE PHOTO BEAM IS NOW DISABLED. PRESS 

P

TO CONFIRM AND QUIT.

NOTE: IF NOT USING PHOTO BEAM

PLEASE CLOSE THIS FUNCTION

AUTO CLOSE ON/OFF

PRESS AND HOLD 

P,

IT DISPLAYS 

“P1”,

PRESS       THREE TIMES, IT DISPLAYS 

“P4”.

PRESS 

P

TO SHOW CURRENT SITUATION. PRESS      TO INCREASE THE 

AUTO-CLOSE ONE MINUTE, AND PRESS      TO DECREASE ONE MINUTE. 
MAXIMUM DEGREE IS 

“B9”

AND MINIMUM IS 

“B0”

.

PRESS 

TO CONFIRM. THE 

DEFAULT SETTING IS 

“B0”

(“

B0”

SHOWS AUTO-CLOSE OFF)

LOCK DOOR

WHEN YOU USE UNCOVERED TRANSMITTERS, IT IS RECOMMENDED TO 
USE THE LOCK DOOR FUNCTION. WHEN THIS FUNCTION WORKS, YOU 

CAN’T OPEN THE DOOR UNTIL YOU PRESS THE “UNLOCK” BUTTON FIRST

PRESS AND HOLD 

P

, IT DISPLAYS “

P1

”, PRESS       FOUR TIMES, IT 

DISPLAYS “

P5

”. PRESS 

P

TO SHOW CURRENT SITUATION. PRESS       , IT 

DISPLAYS “

LC

”, LOCK DOOR FUNCTION WORKS. PRESS      , IT DISPLAYS 

UL

”, THE LOCK DOOR FUNCTION DOES NOT WORK. PRESS 

P

TO 

CONFIRM THE FUNCTION YOU NEED.

Содержание DG-O FORTE

Страница 1: ...GARAGE DOOR OPENER INSTALLATION OWNERS MANUAL ARC DG O FORTE ...

Страница 2: ... DC MOTOR LOW NOISE SOFT START SLOW STOPPING TO PROTECT THE UNIT AND MAKE SURE IT CAN BE USED FOR A LONG TIME LED DISPLAY WORKING SITUATION CAN BE SHOWN ON THE LED SCREEN DECODING ROLLING CODE MANUAL DISENGAGEMENT OPEN AND CLOSE THE DOOR BY HAND WITHOUT POWER OPTIONAL FUNCTIONS PHOTO BEAMS BATTERY BACKUP WALL BUTTON AND FLASH LIGHT SPECIAL PROTECTION FUNCTIONS TRAVEL TIME PROTECTION HALL COMPONENT...

Страница 3: ...INSTALLATION RECOMMENDED TOOLS DRILL STEP LADDER RATCHET TAPE MEASURE CARPENTER S LEVEL SCREW DRIVER TONGS NEON ELECTROSCOPE MULTIMETER ADJUSTABLE WRENCH HAMMER INSTALLING THE OPERATOR AND RAIL ...

Страница 4: ...CONTROL PANEL AND TRANSMITTER ...

Страница 5: ...OPTIONAL TERMINALS AND CONNECTIONS ...

Страница 6: ...ASH FU OR PREVENTING CODING MISTAKES IT IS NECESSARY TO CANCEL ALL STORED CODES TURN ON THE POWER LED DISPLAYS FROM 99 TO 11 AT LAST IT DISPLAYS SETTING OPEN AND CLOSE POSITIONS PRESS AND HOLD P UNTIL IT DISPLAYS P1 PRESS P IT DISPLAYS OP PRESS WHEN THE DOOR HAS REACHED THE OPEN POSITION PRESS P WHEN IT DISPLAYS FU PRESS AND HOLD C CODE THE DOT FLASHES KEEP MORE THAN 8 SECONDS UNTIL IT DISPLAYS DL...

Страница 7: ... THIS FUNCTION AUTO CLOSE ON OFF PRESS AND HOLD P IT DISPLAYS P1 PRESS THREE TIMES IT DISPLAYS P4 PRESS P TO SHOW CURRENT SITUATION PRESS TO INCREASE THE AUTO CLOSE ONE MINUTE AND PRESS TO DECREASE ONE MINUTE MAXIMUM DEGREE IS B9 AND MINIMUM IS B0 PRESS P TO CONFIRM THE DEFAULT SETTING IS B0 B0 SHOWS AUTO CLOSE OFF LOCK DOOR WHEN YOU USE UNCOVERED TRANSMITTERS IT IS RECOMMENDED TO USE THE LOCK DOO...

Страница 8: ...PARTS ARE IN GOOD WORKING CONDITION ADJUST THE TENSILE FORCE OF CHAIN ADD SUTIABLE AMOUNT OF LUBRICANT TO THE ACTIVE SYSTEM EXAMINATION GUIDE Problem Causes Solution The motor does not work The socket is not well connected or the fuse is broken Check the socket Replace the fuse After setting open close positions the motor does not work The screws of fixing the hall components are loose Program mis...

Отзывы: