![Arbonia CICSA CUADRO Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/arbonia/cicsa-cuadro/cicsa-cuadro_user-manual_2962904020.webp)
20
English -
User guide
TMU
Dry-towel models
ZT, ZX, PUKITA, TUBÓN, DIJON, CUADRO, KARNAK, VERONA and ELFIE
MAINTENANCE AND CLEANING
Clean the surface of the towel-rail with a clean and soft rag, do not use abrasive products or corrosive. Stop
the device before proceeding to his cleanliness. For the cleanliness of the box with the controls, use a dry cloth
(without solvent).
Thanks to the high presentations of his materials and the quality of his superficial treatment, towel-radiator is
protected from the corrosion.
TECHNICAL INFORMATION
1. Power: 230V ~ 50Hz.
2. Power of the resistance: 400, 800 or 1.200 W.
3. Temperature of functioning: from 7
0
to 32
0
C.
4. Protection level: Class I.
5. Connection to the radiator: G1/2”.
6. Electronic probe of temperature NTC.
7. Boost Function (Forzed march) 2 hours.
8. Manners of work: Comfort, In The Night,
Antifreee, Stand By and forced March 2 hours.
9. Normative it lowers tension:
CEE n.93/68 and CEE n.89/336 for
Electromagnetic compatibility.
CEE EN 60335-1 and EN60335-2-43.
The following values of factory will become effective:
PARAMETERS
FACTORY SETTINGS
FUNCTIONING
Programmed temperature Comfort
19°C
Boost during time
120 Minutes
Block key
Disable
USER SETTINGS
Level of Descent ECHO
-3,5°C
Established temperature of Antifreeze
7°C
Minimal temperature of Comfort
7°C
Maximum temperature of Comfort
32°C
Boost max. During time
120 Minutes
Maximum established temperature
Automatically of the boost
39°C
Temperature Uni
°C