8
6.
INSTALLATION
6.1.
I
NSTALLING THE
MONITOR
6.1.1.
Place instrument into a 19” rack in an indoor environment.
6.1.2.
Install securely using screws in each of the four front panel corners.
6.1.3.
See Figure 2. Slide switch ‘S1’ to ‘600’ if 600 ohm input termination is desired or to
‘HI’ if a 12k ohm input bridging impedance is desired.
6.1.4.
Connect the power cord to the MONITOR and to the same plug strip that supplies power
to the instruments that will be connected to the input of the MONITOR. The MONITOR
has no power switch. The ‘POWER’ indicator LED will be lit green.
6.1.5.
DO NOT block or otherwise impede airflow through the sides of the instrument.
6.1.6.
Connect the received program material signals into the connectors marked ‘IN’ on the
MONITOR.
If the program material is always mono and only one audio cable is used (single
channel mode), then the MONITOR can be configured for single channel operation.
In single channel mode, the channel A analog input must be used. The default
decoding mode is dual channel.