62
Timing, IRIG-B and Pulses
For details on distributing IRIG-B signals over long distances, see application note, AN101, Dis-
tributing Timing Signals in a High-EMI Environment. Download file appnote101.pdf at the follow-
ing link:
http://www.arbiter.com/resources/documentation.php
For important considerations about IRIG-B connections, distribution of signals and accuracy, down-
load the file,
IRIG-B accuracy and connection requirements.pdf at the following link:
http://www.arbiter.com/resources/documentation.php
.
7.4.3
Synchronizing Multiple IED’s From One Masterclock Output
In many installations, master clock signals are “fanned out” to a number of devices. This method
makes more efficient use of the clock synchronizing capability since the clock drivers are designed to
handle multiple loads. To compute number of possible loads per output, first determine the input
impedance of each connected IED. For example, if the input impedance of the IED is 5 kilohms,
determine the device current (I) as follows:
(7.1)
I
=
V
÷
R
dev
= 5
V olts
÷
5000
Ohms
= 0
.
001
Amps
(1
mA
)
If you were to connect ten of the same IED’s to the same output, then the total current drawn
would be 10 x 0.001 A = 0.01 A (10 mA).
7.4.4
Connecting Unmodulated IRIG-B
To drive multiple loads from one unmodulated IRIG-B output, make sure that the loads are wired
in parallel. Some technicians might call this “daisy-chaining”, however the idea is to drive all of
these loads in parallel from the single output. It is much simpler to connect loads to unmodulated
IRIG-B than for modulated, because all of the loads are driven at the same voltage.
To determine load current for one Unmodulated IRIG-B output:
1. determine the desired number of loads to be connected to a single clock output
2. determine the impedance (or resistance) of each load
3. calculate the load current for each device (
I
dev
= 5
V
÷
R
dev
)
4. sum up all the load currents for the total current for one clock output.
Another method is to determine the lumped impedance of all of the connected IED’s in parallel.
Then, determine the overall current by dividing the drive voltage (5 V) by the computed lumped
impedance value. This current should not exceed 18 mA for each output.
7.4.5
Connecting Modulated IRIG-B
The total load capacity for the modulated IRIG-B driver depends on the type and number of loads.
The main difference in computing the load capacity for modulated IRIG-B and unmodulated IRIG-
B is that many of the modulated IRIG-B decoders are fairly sensitive to the peak-to-peak voltage.
When adding loads, the clock’s modulated driver produces more current, which is passes through
the internal source resister, dropping the available output voltage. The open circuit voltage (i.e.
Содержание 1088A
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 18: ...xviii LIST OF FIGURES ...
Страница 23: ...1 4 Attaching Rack Mount Ears to 1088A B Series Clocks 3 Figure 1 2 Attaching Rack Mount Ears ...
Страница 24: ...4 Unpacking the Clock ...
Страница 32: ...12 Front and Rear Panels ...
Страница 38: ...18 Connecting Inlet Power Input and Output Signals ...
Страница 41: ...4 1 GPS Antenna Installation 21 Figure 4 2 Antenna Mounting Bracket Figure 4 3 Antenna Mounting with AS0044600 ...
Страница 46: ...26 GPS Antenna and Cable Information ...
Страница 48: ...28 Setting Internal Jumpers Figure 5 1 Model 1088B Main Board ...
Страница 76: ...56 The Setup Menus ...
Страница 112: ...92 Serial Communication and Command Set ...
Страница 127: ...B 4 Physical Dimensions 107 Figure B 1 Suggested Mounting of the AS0094500 Surge Arrester ...
Страница 128: ...108 Using Surge Arresters ...
Страница 137: ...C 5 Option 04 Parallel BCD Output 117 C 5 2 Option 04 Firmware Setup Figure C 2 Option 04 Firmware Setup ...
Страница 145: ...C 5 Option 04 Parallel BCD Output 125 Figure C 4 Option 04 Output Jumper Settings ...
Страница 146: ...126 Options List Figure C 5 Option 04 Board Layout and Jumper Locations ...
Страница 165: ...C 12 Option 17 Parallel BCD Output and Second RS 232 Port 145 Figure C 11 Option 17 Output Jumper Settings ...
Страница 166: ...146 Options List Figure C 12 Option 17 Board Layout and Jumper Locations ...
Страница 176: ...156 Options List C 14 5 Typical Network Configuration Figure C 15 Option 18 Network Configuration ...
Страница 187: ...C 16 Option 20A Four Fiber Optic Outputs 167 Figure C 22 Option 20A Jumper Locations ...
Страница 194: ...174 Options List Figure C 24 Option 23 Internal Jumper Setup ...
Страница 196: ...176 Options List Figure C 25 Option 27 Jumper Locations ...
Страница 214: ...194 Options List Figure C 28 Option 29 Connector Signal Locations ...
Страница 270: ...250 Options List ...