Страница 1: ... read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for future reference Portable Air Conditioner For model PC14E Owner s Manual Innovative AutoDrain Technology ...

Страница 2: ...it Installation 7 INSTALLATION 8 OPERATION 9 Turning the Unit On 9 Setting the Clock 9 Setting theTemperature 9 Mode Button 9 Fan Speed 9 To Set theTimer 9 Canceling theTimer Function 11 Sleep Mode 11 REMOTE CONTROL 12 EMPTYING THE INTERNAL WATER CONTAINER 13 MAINTENANCE 14 Cleaning the Unit 14 Cleaning the Filter 14 End of Season Storage 14 TROUBLESHOOTING 15 WARRANTY 18 1 ...

Страница 3: ...nology In designing these advanced products we have listened carefully to our customers and have passed their views on to our research and development laboratories We wish you many years of enjoyable use After reading this manual please keep it in a safe place for future reference Energy Saving Tips Do not locate the air conditioner where furniture or other objects can obstruct the airflow Keep do...

Страница 4: ...cooling capacity of the unit may be affected by the height of your ceiling quality of your insulation or number of windows in your room There is no current testing statute for portable air conditioning products in the United States yet we have made every effort to design engineer a superior quality portable air conditioning unit that effectively and efficiently cools select areas of the home or of...

Страница 5: ... or wet areas Always transport the unit in an upright position Do not sit or stand on the unit Do not place objects on the unit Do not touch the unit with wet damp hands or when standing barefoot Drainage of the water container is required before moving the unit or putting it into storage If the electric socket is different from the plug provided have a professionally qualified electrician replace...

Страница 6: ... Bar Connector Adjustable Window Slide Bar Spiral Water Pipe with Connector Drain Hose 08 15 75 ºF 24 00 00 00 06 00 18 00 12 00 Display FAN COOLING 08 15 HOURS MINUTES 75 F TEMPERATURE ON OFF UP FAN DOWN Air Filter pre installed Filter Frame Filter With Permanent Washable Filter ...

Страница 7: ...lace Assemble the hot air hose on the unit Clip on the water atomizer at the end of the spiral pipe to the holder Unfold flexible hose with attached hose adapter connector and snap into Window Slide Bar AutoDrain Technology Assembly 2 3 6 8 4 5 7 1 Attach Window Slide Bar Connector to Exhaust Hose by twisting as shown Only Required For Disassembly In order to unlock the quick connector push the ta...

Страница 8: ...d of the Hose by extending hose at least 6 Then tighten Hose by turning the Slide Bar Connector clockwise 3 Place Adjustable Slide Bar in the window and expand so it fits tightly 4 Mark Slide Bar to record width of the window 5 Apply Insulation Strips on top and bottom of Slide Bar 6 Reposition Slide Bar Connector in the window Expand the Slide Bar to fit tight Tighten the screws 7 Lower the windo...

Страница 9: ...8 Installation WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not extend it with your own hose as this could cause the unit to malfunction ...

Страница 10: ...IME button the minute digits will flash 4 Press UP or DOWN to adjust the minutes 5 Press the TIME Button to Set C Setting the Temperature To change the set temperature press the Up Down button The 2 digit display will indicate the set temperature NOTE Reaching the set temperature depends on the room and outdoor climatic conditions The set temperature range is 64 F to 90 F D Mode Button Press the M...

Страница 11: ...lar time scale will be on between the ON programmed times until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time then the black segments in the circular time scale will disappear Programming the Timer for OFF Perform the standard steps as described above The circular time scale will be on between the pres...

Страница 12: ...ver a 3 hour period to meet the needs of a body at rest To activate the SLEEP MODE Ensure the unit is operating in Cool Mode Set the desired starting temperature Press SLEEP MODE button In sleep mode fan will operate in low speed To cancel this function press SLEEP MODE button again Shutting Off the Blue Light on Control Panel Normally there is a blue light on the LCD display To shut it off press ...

Страница 13: ...temperature using the UP DOWN buttons 4 To Adjust FAN SPEED Press FAN button to select speed 5 To Set the TIMER A SET START TIME Press timer ON button and set the ON hour using the UP and DOWN buttons Press timer ON button and set the minutes using the UP and DOWN buttons Press timer ON to finish B SET OFF TIME Press the timer OFF button and set the OFF hour using the UP and DOWN button Press the ...

Страница 14: ...ound in most portable air conditioners Switch off the unit and remove the plug from the outlet Position a flat container or dish on the floor under the drain hole Do not allow the water to drip continuously into the container as it might easily overflow Remove the drain knob Remove the rubber plug the water will flow in the container When this is nearly full replace the plug to stop the water flow...

Страница 15: ...reassembling the fixer into the filter holder see fig 3 NOTE Before storage be sure filters are clean and dry Should you need to replace filters contact Arbaco for replacement The screen filter must always be used Filters can be vacuumed IMPORTANT NEVER operate the unit without a filter At the end of AC Season this unit should be drained prior to storage Refer to Emptying the Water Container secti...

Страница 16: ...m temperature lower than the selected value Lower temperature selected The overheat protection is activated Wait 3 minutes until temperature has decreased then turn on again The Unit is Noisy Unit is not standing on a level surface Place on an even surface The Remote Control Does Not Function Distance too great Make sure the remote is aimed at the control panel Remote control signal not detected b...

Страница 17: ...ER Damage accidental or otherwise to the unit while in the possession of the consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by the wear Damage caused by repairs or alterations of the unit by anyone...