Содержание Therapy Care C

Страница 1: ...Rev 6 ...

Страница 2: ...of treatment 05 Refilling and emptying the tank 06 Features and Technical Sheet 07 Problem resolution 08 Alarm indication of low fluid level 08 The equipment does not turn on normally 08 The equipment does not respond to the keys on the screen 09 Contraindications and precautions 09 Cleaning and maintenance 10 Cleaning of the Equipment 10 Cleaning of the exchangers 10 Preventive maintenance 10 Equ...

Страница 3: ...e Therapy Care C helps you regain your physical shape better and faster and does so by enhancing the body s natural mechanisms using the power of cold applications combined with the application of sequential hydraulic compressions Therapy Care C is not a medical device The use of the equipment to carry out physiotherapy or rehabilitation treatments will always be carried out under the supervision ...

Страница 4: ...RTANT Never tip or lean the equipment on one of its sides this will cause damage to the equipment and invalidate the warranty 2 Turning on the equipment Once the equipment is installed and plugged into an outlet Press the green power button on the equipment Power Switch Wait for the equipment to boot alone and load the application If this is the first time you will get the screen Insufficient flui...

Страница 5: ...out requiring any intervention 8 Cancel treatment At any time you can cancel the treatment by pressing the square shaped key which is located in the center of the screen below Default values The equipment takes as default values both temperature treatment times compression levels the last treatment performed USE OF THE EQUIPMENT Start up 1 Press the power switch 2 Click on the text Therapy Care C ...

Страница 6: ...will enter the compression level selection and display screen During the treatment you can modify at any time the level of compression massage Treatment completion Once the treatment is complete the exchangers emptying screen appears Once the exchanger draining is complete the treatment completed screen appears If you click on the equipment you start preparing temperatures for a new treatment Duri...

Страница 7: ... The emptying and filling of the tank is automatic To proceed with emptying the tank Connect the tube for emptying in the socket marked with blue on the side of the equipment and the other end of the tube insert it into an empty bottle and press the emptying button key on the right The equipment will start emptying the tank once we see that fluid no longer comes out press the key To proceed with f...

Страница 8: ... module Thermal protection through internal safety thermostats Digital temperature control Digital temperature and safety sensors Pressure sensors in each of the hydraulic circuits Digital level sensors Low fluid level indicator User Interface Touch screen Temperature exchangers adaptable to each of the areas to be treated Polystyrene PS chassis meets flammability standard UL 94 The circulating fl...

Страница 9: ...been completed to exit the Fill empty tank screen press the key RESOLUTION OF PROBLEMS The equipment does not turn on normally Or when we are going to turn it on we find that the power switch is previously activated green light on and the equipment do not start do not load the program Press on the power switch to remove power from the equipment Wait 5 seconds Re act on the power switch and wait fo...

Страница 10: ...nd proceed to turn it on If the problem persists or repeats notify the technical service The equipment do not respond to the keys on the screen ON OFF SWITCH Therapy Care C is not a medical device so the use of the equipment for physiotherapy rehabilitation treatments will always be carried out under the supervision of qualified personnel Condensation In environments with high levels of humidity a...

Страница 11: ...s in the section Tank emptying Filling Oncological pathology or carrier of a chronic disease in terminal stage Serious circulatory disorders central or peripheral the latter with some nuances if the temperature is properly regulated Oncological pathology or carrier of a chronic disease in terminal stage Post acute myocardial infarction cerebral infarction atrial fibrillation heart failure Hyperten...

Страница 12: ...he Official Technical Service The user must not attempt to repair any malfunction by himself Manufacturer and technical service ARB Systems Proyectos Electrónicos SL C Pico de la Sierrona 135 28400 Collado Villalba Madrid Tlf 34 918 287 364 Email arb systems arb systems com CONTACT Our team will be happy to answer your calls or answer your e mails Do not hesitate to contact us and we can give you ...

Страница 13: ...DECLARATION OF CONFORMITY ...