5 Mounting & Connecting the Electrical System
35
5.2.2.2
Dual Air Locker System
If two
Air Locker
s are to be installed in the system, ARB
recommends that the switches and solenoids be wired according to
figure 23. For safety reasons, this configuration allows SOLENOID
2 to be actuated only if SOLENOID 1 is already on.
Attach the “REAR AIR LOCKER” switch cover to SWITCH 1, and
the “FRONT AIR LOCKER” switch cover to SWITCH 2.
NOTE :
Refer to Figure 21. for the correct switch terminal
identification and switch orientation.
Configure SOLENOID 1 as the air line leading to the rear axle
Air
Locker
, and SOLENOID 2 as the air line leading to the front axle
Air
Locker
.
Figure 23.