PRELIMINARY SETUP FOR USE

Set flowmeter constant (

B

, Fig. 9): on the computer connected to Orion 2 flowmeter: refer to the label on the body (

A

, Fig. 9) and tables 7a-7b-7c - 

Chap. 5 "Technical data".

Rubiera  (RE)

MADE

IN

ITALY

H195099

s/n :

10 ÷ 200  lit/min  300  pls/lit

2.6 ÷ 53  GPM  l 1135  pls/GAL

20 bar 290 psi

40 bar 580 psi

QC PASSED

12VDC

300mA

}

A

40 bar 580

B

1135 pls/GAL

For further information regarding how to set the constant, consult the use and maintenance manual of the computer being used. 

USE

When using the system, the flowmeter sends impulses to the computer, which, according to the constant value previously set, indicates the instant flow.
A LED in the connector slot indicates the status of the device (Fig. 10):

Orion 2 flowmeter can only detect conductive fluids with a conductivity equal to 50 μS/cm (Rif. Tab. 5.2 - Chap. 5).
- Do not aim pressurised water onto the equipment.
- Respect the device’s rated power requirement (12 Vdc).
- If arc welding is required, ensure that flowmeter power is off and disconnect the power cables, if necessary.
- Use the flowmeter only within the flow limits given in the “Technical data” table. Outside these limits, the flowmeter could give incorrect 
data and therefore lead the operator or the automatic system to make errors.
ARAG cannot be held responsible for damage caused to persons, animals or things by incorrect or unsuitable use of the flowmeter or its parts.

Fig. 9

Fig. 10

 

LED OFF:

 

the device is not powered.

 

LED ON NOT FLASHING with low light intensity:

 

the device is powered but it does not detect liquid passage.

 

LED ON FLASHING with high light intensity:

 

the device is powered and it detects liquid passage. 
La frequenza dell'intermittenza è proporzionale alla portata.

Содержание Orion 2 46211A Series

Страница 1: ...46211AXXXXX 46221AXXXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE...

Страница 2: ...3 Preliminary setup for use 10 4 Use 10 5 Maintenance 11 5 1 Troubleshooting 11 5 2 Technical data 11 12 6 Guarantee terms 13 7 Disposal at the end of service 13 This manual is an integral part of th...

Страница 3: ...h EN ISO 14982 standard Electromagnetic compatibility Forestry and farming machines harmonized with 2004 108 EC Directive The flowmeter must not be used to measure the passage of hydrocarbons flammabl...

Страница 4: ...463 863 46211A00000 5 96 90 114 41 46211A10000 7 96 90 114 41 46211A20000 10 96 90 114 41 46211A30000 14 96 90 114 41 46211A40000 18 5 96 90 114 41 46221A40000 18 5 96 90 114 45 473 873 46221A50000 28...

Страница 5: ...7 G 3 4 96 90 184 46211A21313 10 G 3 4 96 90 185 46211A23333 10 G 3 4 96 90 184 46211A31414 14 G 1 96 90 185 46211A33434 14 G 1 96 90 184 46211A41414 18 5 G 1 96 90 185 46211A43434 18 5 G 1 96 90 184...

Страница 6: ...6 Dimensions mm DN H L T A T CODE DN T A H L 46211A3A5B5 14 T5 96 90 192 46211A4A5B5 18 5 T5 96 90 192 Fig 4 Tab 3...

Страница 7: ...upwards OK OK Comply with the correct fluid inlet outlet direction as indicated by the arrow printed on the flowmeter body Fig 6 IN OUT IN OUT Use inlet and outlet pipes of the same diameter as the in...

Страница 8: ...ve 2 4 Hydraulic connections For connection to the system use appropriate fittings Ref ARAG General catalogue Avoid bends and constrictions before connections and on tubes Regarding connections use tu...

Страница 9: ...UNIT MAKE SURE THAT THE OPERATING PRESSURE IS SUITED FOR THAT SPECIFIC CONTROL UNIT FLOWMETERS WITH T5 FORK COUPLING CAN WITHSTAND A MAXIMUM PRESSURE OF 20 BAR ARAG is not liable for damages to the eq...

Страница 10: ...t conductive fluids with a conductivity equal to 50 S cm Rif Tab 5 2 Chap 5 Do not aim pressurised water onto the equipment Respect the device s rated power requirement 12 Vdc If arc welding is requir...

Страница 11: ...he flowmeter does not read any value No power supply Check the flowmeter wiring The value read by the flowmeter is not linear or stable Presence of turbulence or air in the circuit Check the circuit 5...

Страница 12: ...22710 46211AG3333 0 3 6 0 08 1 6 40 580 0 3 4 G 3 4 4 6000 22710 46211A01313 0 5 10 0 13 2 6 20 290 0 3 4 G 3 4 5 6000 22710 46211A03333 0 5 10 0 13 2 6 40 580 0 3 4 G 3 4 5 6000 22710 46211A11313 1...

Страница 13: ...lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compati...

Страница 14: ...14...

Страница 15: ...ntemplati nella seguente Direttiva Europea 2004 108 CE e successive modificazioni Compatibilit Elettromagnetica Riferimenti alle Norme Applicate EN ISO 14982 Macchine agricole e forestali Compatibilit...

Страница 16: ...RA Reggio Emilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the construct...

Отзывы: