PRElImINARY SETUP FOR USE

For a correct display of data regarding treatment, some preliminary set ups are necessary when installing DigiWolf on farming machines.

4.1 Calibration

Rate reading may not be correct due to different system configurations (tubes, valve, etc.). Therefore, we recommend to make 
a spray test; in case the measured value is different from the real one, perform an automatic calibration procedure or manually 
calculate flowrate constant.

4.1.1 

Automatic calibration

Make a quantity of liquid previously measured or that can be measured with another system go through the flowmeter

. The greater the amount of 

liquid used to perform the calibration procedure, the more accurate the calibration.

End reading

0.0 l/min

¬

¬

2) Access Automatic calibration menu (Setup menu > Calibration > Auto calibra-
tion). 

Once inside the menu, the device is ready to start measuring without 

any further controls.

Calibration

67.58 l

¬

¬

C

D

067.58

0

o

1

2

B

A

3) Make the liquid go through the system. The display will start to show the incre-
asing value of the measured quantity of liquid. Once liquid passage has finished, 
the value on the display will not change any more.  

 

At this point, press 

OK

. In the lower part of the display, the message 

Stabi-

lization

 will come up and the device will show the screen on the side.

1

 Setting of liquid amount actually passed through the flowmeter during calibration procedure.

2

 Display of liquid amount read by the flowmeter during calibration procedure.

4) Using the keys, enter the values of the liquid quantity previously measured:

A)

 Press to toggle from one digit to another

B)

 Press in succession to modify the value of the digit highlighted by the cursor

C)

 Press to complete calibration procedure, or 

D)

 Press for 1 sec. to cancel calibration procedure.

If, after starting calibration, the device does not sense any flow passage (and the display remains in 0), press 

OK

 to exit the calibration 

procedure without saving.
If the device continues to sense the liquid flow after pressing 

OK

, after a few seconds the error message 

Stop flow!

will be displayed. 

Once the flow has been interrupted, the reading will stabilize as by standard procedure.

Fig. 17

Fig. 18

SETUP

Содержание DigiWOLF 4627 Series

Страница 1: ...4628405 4628506 4628707 CELL POWERED VERSION Software rel 1 0X INSTALLATION USE AND MAINTENANCE digi...

Страница 2: ...ment to which it refers and must accompany the equipment in case of sale or change of ownership Keep it for future reference ARAG reserves the right to modify the specifications and instructions regar...

Страница 3: ...10 4 1 1 Automatic calibration 10 4 1 2 Manual calibration 11 4 2 Flowrate alarms 12 4 3 Display 12 4 4 Energy saving 13 4 5 Options 13 4 5 1 Language 13 4 5 2 Units of measurement 14 4 5 2 1 Rate un...

Страница 4: ...man consumption 2 Flowmeter ASSEMBLY Install the flowmeter at least 20 cm from the elements that could cause turbulence inside the tubes valves bends constrictions etc The flowmeter can be installed i...

Страница 5: ...e seen these correspond to the two possible monitor positions parallel and perpendicular to the body DigiWolf is supplied with the sensor in position A parallel to the body With the aid of a screwdriv...

Страница 6: ...ementation on already operating systems it is necessary to follow all safety rules described herein System assembly and start up must be carried out by expert personnel according to the safety rules s...

Страница 7: ...ery case and that the lid seal remains in its seat A B C To avoid damaging the device replace low batteries as soon as this symbol is displayed Remember to remove the batteries when the device is not...

Страница 8: ...for 2 seconds at the same time to access setup menu Setup menu Calibration Flowrate alarms Display A B SELECTION AND ACCESS TO MENU ITEMS A Press in succession to move through items the selected item...

Страница 9: ...sion Sensor frequency 2 98V Par 4 6 1 Test Display test Sensor frequency Battery voltage Par 4 6 2 Test Keys test Battery voltage Display test Setup menu Calibration Flowrate alarms Display Setup menu...

Страница 10: ...display will start to show the incre asing value of the measured quantity of liquid Once liquid passage has finished the value on the display will not change any more At this point press OK In the low...

Страница 11: ...on Flowrate constant Min value Max value C 1 50000 B D A 0600 0 2 Using the suitable keys set the value of the flowmeter constant A Press to toggle from one digit to another B Press in succession to m...

Страница 12: ...D A 0040 0 0 l min o 3 Set flowrate alarm value A Press to toggle from one digit to another B Press in succession to modify the value of the digit highlighted by the cursor C Press to save changes or...

Страница 13: ...saving Under the selected item the currently set value will be displayed Press OK to access modification of the selected item Backlight shut off Min value Max value C 1 300 B A 30 0 s C 2 Set the valu...

Страница 14: ...te units of measurement selection 2 1 2 Flowrate l min GPM m h 3 1 Select measurement unit using 2 Press OK to save or ESC to exit without saving 4 5 2 2 Volume units of measurement Units of measurem...

Страница 15: ...ration of the display on the device Test Display test Sensor frequency Battery voltage Access display test menu Setup menu Test Display test Press OK The display shows all pixels on Press ESC to retur...

Страница 16: ...will zero Do not place DigiWolf under pressurized water Use the flowmeter only within recommended rate range Tab 2 Par 2 3 1 Beyond these limits the flow meter may give out incorrect data To avoid dam...

Страница 17: ...g the sensor or the paddle check for the correct reading of the flowmeter Proceed to a new calibration if necessary 6 1 Troubleshooting FAULT CAUSE REMEDY The display is off No power supply Check for...

Страница 18: ...several hours 6 Wash the paddle group thoroughly with running water and check its correct operation If necessary replace the complete paddle group with its suitable spare part code 4626000 500 7 Refit...

Страница 19: ...as follows 1 Remove the fork from the ring nut using a screwdriver 2 Remove the ring nut OR replacement Replace the ORs code G10051V ARAG spare parts catalogue 3 Refit the sensor housing block ensurin...

Страница 20: ...Portugu s Fran ais Deutsch Cesky Polski Magyar Rate units of measurement l min Units of measurement settings l min GPM m3 h Volume units of measurement litres Units of measurement settings l gal m3 7...

Страница 21: ...Notes 21...

Страница 22: ...allation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing...

Страница 23: ...i nella seguente Direttiva Europea 2004 108 CE e successive modificazioni Compatibilit Elettromagnetica Riferimenti alle Norme Applicate EN ISO 14982 Macchine agricole e forestali Compatibilit elettro...

Страница 24: ...ALY Via Palladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the constr...

Отзывы: