32
Exit the function
or data change
Confirm access
or data change
Scroll
(LEFT /
RIGHT)
Delete
selected
character
Data
decrease
of data
Scroll
(UP /
DOWN)
Enter
selected
character
Par.
ADVANCED SETTINGS
"IMPLEMENT"
11.4.11 Working parameters
Set the farming machine job limits.
SPRAYING LIMITS
• Spraying speed limit
Enable the function to set the spraying speed limit.
Limit enabled
Limit disabled
• Minimum spraying speed
Set the minimum spraying speed:
The monitor closes the main valve when the tractor speed is lower than the set value.
• Regulation pressure limit
Enable the function to set the regulation pressure limit.
Limit enabled
Limit disabled
• Minimum regulation pressure
Set the minimum spraying pressure:
The monitor blocks the automatic regulation of the proportional valve when the pressure is lower than the set value.
• Flowrate correction factor
When using a paddle flowmeter and the sprayed fluid has a different viscosity than that of water, the computer could display wrong measurements;
to correct them change the flowrate correction factor:
• if at the end of the spraying the tank still contains fluid, reduce the factor;
• if the fluid finishes before the job has ended, increase the factor.
Flowmeters of the ORION series (code 462xxx) are not affected by the viscosity difference of the fluids: set the factor to
1.00.
• Tank level correction factor
If the sprayed fluid is lighter than water, the device may indicate wrong measurements; to correct this measurement, edit the sprayed liquid weight,
referred to 1 liter of product.
*
Item
Tank level correction factor
is present only if
Tank level sensor
has been enabled in chapter 10 “Basic setup”.
CONTINUES > > >