Cassette Stove Installation Guide
is lit and the functioning of the chimney system is checked for satisfactory
operation.
• Be sure that the chimney is operating and all smoke and fumes are vented
to the atmosphere through the chimney terminal.
• Check all joints and seals.
• Clean the outside of the cold appliance with a lint free cloth or shoe brush
to prevent any stains becoming burnt on.
• Check the flue draught which should read 10 - 20pa, or 0.1 - 0.2 mbar.
Consult a suitably qualified person who will have the knowledge and
equipment to perform a test.
• For a registered Competent Persons scheme (such as those referred to
at www.gov.uk/building-regulations-competent-person-schemes ), please
complete a Certificate of Compliance, which is used for checking and
reporting the installation as imposed by the Government. Otherwise please
ensure the installation is approved by your local building control officer.
• Ensure a Carbon Monoxide alarm is fitted. This must be between 1m to 3m
from the appliance, and approximately 150mm below the ceiling level.
• A fireguard conforming to BS 8423:2002 should be used in the presence of
children or infirm people.
• A notice plate should be provided containing information on the
performance characteristics of the hearth, fireplace, flue or chimney.
• Explain the following to the customer:
How to operate the riddling mechanism and air control lever.
The importance of an adequate air supply to the room.
The importance of regularly having the chimney swept / inspected.
That a protective glove should be used when operating the stove.
How changes in the weather can effect the performance of the stove.
Using the correct fuels.
BK605 Rev02