Arad Octave Скачать руководство пользователя страница 3

3

3.0 

Items included with order:

•  One OCTAVE ultrasonic flow meter, size as indicated on the packaging box, 

pieced together into a complete compact system (flow tube plus electronics)

•  One OUTPUT module, either digital or analog (based on the customer’s order)

4.0 

Supplied Documentation:

•  Condensed installation and user manual
•  Report of factory meter settings
•  Certificate of calibration data

5.0 

Unpacking and Inspection

•  This product has been thoroughly inspected and tested before shipment and is ready for operation.
•  After carefully unpacking the meter, inspect for shipping damage before attempting to install. If any indication 

of mechanical damage is found, immediately contact the responsible transportation service and your local ARAD 
LTD. representative.

6.0 

System Descri ption and Measurement Method  

•  The OCTAVE’s measurement method is based on an ultrasonic, transit-time, dual-beam sensor which determines 

the length of time it takes an ultrasonic sound wave to travel the distance between the two sensors located on the 
meter’s body. The two sensors function as both the sender and the receiver, each one alternating these functions 
so that the ultrasonic wave travels both with and against the direction of the flow. Since the ultrasonic wave travels 
slower against the flow than with the flow, the time difference of two waves traveling with and against the flow leads 
to determining the velocity of the water

•  The OCTAVE ultrasonic flow meter is a battery-powered precision flow meter designed for linear, bidirectional flow 

measurement of water

•  Flow measurement values can be transferred through the standard digital or analog output
•  The OCTAVE can be set up for a wide range of applications

7.0 

Mechanical Data

Maximum Working Pressure
Liquid Temperature
Precision Class
Configuration 
Power Source
Environmental Protection

Display Units

Output (optional)

16

 bar                

0.1-50

°C

ISO 

4064 rev.2005

Compact - The display is built in to the unit

D size Li-battery 

-10

 years life time

IP 

68

, Ambient operation temp. 

-25

°C 

÷

 

+55

°C

Multi line 

9

 digit LC display (Programmable - m

3

USG, CuFt. Acre Feet, Flow rate and volume)
Programmable dual open collector pulse output
Powered loop 

4-20

 mA

Содержание Octave

Страница 1: ...I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies ...

Страница 2: ...limited warranty and is exclusive and in lieu of all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose and shall constitute the Customer s sole and exclusive remedy with respect thereto Replacement or repair in the manner provided above will constitute fulfillment of all of Arad s obligations with respect...

Страница 3: ...tween the two sensors located on the meter s body The two sensors function as both the sender and the receiver each one alternating these functions so that the ultrasonic wave travels both with and against the direction of the flow Since the ultrasonic wave travels slower against the flow than with the flow the time difference of two waves traveling with and against the flow leads to determining t...

Страница 4: ...ot lift the Octave by the electronic housing Do not carry the Octave by his lid Do not place the Octave on the electronic housing When handling the Octave avoid hard blows jolts or impacts Model Octave Nominal size mm 50 50 Threaded 65 80 100 inch 2 2 Threaded 2 5 3 4 L Length mm 200 300 200 225 250 B Width mm 165 113 185 200 220 H Height mm 194 155 210 210 223 h Height mm 40 35 90 90 103 Weight k...

Страница 5: ...5 pipe diameters after pumps Minimum of two 2 pipe diameters after strainers Minimum of two 2 pipe diameters before and after Minimum of two 2 pipe diameters before T connections Zero 0 pipe diameters before and after elbows 90 in vertical installations Flow Direction Flow Direction Flow Direction Flow Direction O DN Flow Direction 2 DN 2 DN 2 DN 2 DN Flow Direction ...

Страница 6: ... of the flowmeter should be at the lowest point Always install control valves downstream of the meter in order to avoid cavitation ever install the meter on a pump suction side in order to avoid cavitation 10 0 Pipe flanges Refer to the standard dimensional drawings for flange spacing accommodating for the thickness of gaskets Install meter in line with the pipe axis The pipe flange faces must be ...

Страница 7: ...passive current output Supplied Cable Length 3 meters Loop supply voltage 12 24 Vdc Output Impedance 25 MΩ typ Output wire colors Warning Signal connection polarity is mandatory The current output is a passive 4 20mA 4mA is always 0 zero flow and the 20mA is factory programmable according to the customer requirements If the customer did not specify the 20mA will be the maximum flow rate 12 2 4 20m...

Страница 8: ...des Pic 1 1 Output module 2 2 Allen Screws 3mm X 20mm 3 O ring 4 Sealing cap 5 3mm Allen key Stage 1 Using the 3mm Allen key disassemble the cover Pic 2 from the meter keep the cover the screws and the O ring for future use Pic 3 Pic 2 Pic 3 Stage 2 Place the O ring in the groove Pic 4 5 Pic 4 Pic 5 Stage 3 Insert the output module into the plug Pic 6 and tighten the screws with the 3mm Allen key ...

Отзывы: