E

OPTIONAL PARTS DIMENSIONS

I. 

ZERO POINT 

RESET

Under measure mode, press      button 

for 1 ~ 3 seconds.

H. 

PRESSURE UNIT SETTING MODE

Press      button for more than 3 seconds.

Measure mode

Use      button to set desired pressure unit.

Unit setting

Measure mode

MPa

MPa

MPa

Measure mode

MPa

Measure mode

MPa

Zero point setting

MPa

MPa

F. 

PRESSURE UNIT CONVERSION TABLE

J. 

DUST AND SPLASH 

ENVIRONMENT

To maintain IP65, please insert an air 
tube (O.D.: 4mm) into atmospheric 
release port and pipe the other end away 
from dust / spattering liquid environment.

Use pr

oper air tube dimension of 

O.

D.: 4mm, I.D.: 2.5mm, and the length 

is de

pending on

 the user’s environment.

Atmospheric release port 

Air tube

Do not press      button for 3 seconds to return

to measure mode.

Release the button when “       ” is shown.

K. 

ERROR CODE INSTRUCTION 

 

Residual  

pressure error

During zero reset, ambient 

pressure is over 

±3% F.S.

 

Change input pressure to ambient 

pressure and perform zero reset again.

Applied 

pressure error

Supply pressure exceeds the 

upper limit of pressure setting.

Adjust the pressure within operating

pressure range.

Error Type Error code

Error Condition

Troubleshooting

Battery 

error

When battery level is under 

2.40V, the battery symbol 

and         will flash 4 times 

then enter power save mode.

Replace battery.

From

To

1 MPa

0.006895

0.07031

1

0.06895

10

145.038

10.197

1

0.100000

1.01972

14.5038

1

0.980665

14.2233

1

0.0980665

1 kgf/cm

2

1 psi
1 bar

MPa

kgf/cm

2

psi

bar

G. 

POWER-SAVE MODE

Measure mode

Power-Save mode

MPa

◎ 

The pressure gauge will enter power saving mode if the      button is not 

      pressed within 60 sec.

No button operation for 60 seconds

Panel adapter

Front protective lid

Panel adapter

PA-D

MPa

kgf

bar

psi

PAP