AR INDAP62 Скачать руководство пользователя страница 1

Unit:mm

We reserve the right to change the specification without prior notice.

PR-0467C   2022/03 Printing

9

6

15.5
22.5

20

20

30

30

37

21.8

Rated pressure range

Withstand pressure

Applicable fluid

k

gf/cm

2

b

ar

p

si

Pressure

resolution

Ambient humidity range

Vibration

Shock

Temperature characteristic

 Weight

MPa

A. 

SPECIFICATIONS

TYPE

(Positive)

INDAP62

Battery 

Battery life
Low-power indicator
Battery replaceable
Turn-on interval
Sampling rate

Repeatability
Display

Indicator accuracy

C. 

DIMENSIONS

Battery Meter

www.ar-vacuum.com

www.ar-vacuum.com

www

.ar-vacuum.com

Pressure Display

Setting Button

Pressure Unit 

Display Section

D.

 

BATTERY STATUS / INSTALLATION

G1/8"(BSPP), M5

1

4

7

8

MPa

MPa

6

"+"

"-"

1.5MPa

0.

000

 ~ 1

.

000

M

Pa

Filtered air, incombustible and non-corrosive gases

mmHg

kPa

 Operation/Storage: 35 ~ 85% RH ( No condensation)

Total amplitude 1.5mm or 10G, 10Hz-55Hz-10Hz scan 

for 1 minute, two hours each direction of X, Y and Z

 100m/s

2

 (10G), 3 times each in direction of X, Y and Z

Approx. 40g

Yes
Yes

2 Hz (2 times/sec.)

±0.2% F.S. ±1digit

3 ½ digital, 7 segment LCD display ( Black )

±2% F.S.  ±1 digit  (ambient temperature: 25 ±3 °C)

Operation: 0 ~ 50 ºC, storage: -10 ~ 60 ºC 

( No condensation or freezing)

±2% F.S. of detected pressure (25°C) 

at temp. range of 0~50°C

Ambient temp. range

Enclosure

 Environment

5

2

3

INDAP62

Do not use corrosive or flammable gas or liquid with this product.

Please use within the rated pressure range. Do not apply 

pressure beyond recommended maximum withstand pressure, 

permanent damage to the pressure gauge may occur. 

Do not drop, hit or allow excessive shock. Even if press

ure gauge 

body

 appears undamaged, internal components may be broken 

and can cause malfunction.

Do not use in environment containing steam or oil vapor.

This product is not explosion-proof rated. Do not use in 

atmosphere containing flammable or explosive gases.

Using filter can extend pressure gauge’s service life.

For your safety, please read the following before using.

1
2

3

4
5

6

FOLLOW THE STEPS BELOW

● 

Using a flat screwdriver size 1.4 ~ 3.0 mm insert into the back of the 

   pressure gauge as pictured. (See figure     )

● 

Turn the screwdriver horizontally 90° to separate the case and the base. 

   Repeat this process again for the other side. (See figure     )

● C

arefully remove the outer cover (See figure     ), and follow the diagrams 

   below to replace battery and reassembly. Polarity must be observed, 
   incorrect battery installation will cause malfunction.

2

3

4

CR 2032 lithium

IP65* 

-0.100

 ~ 1

.

000

M

Pa

Display pressure range

Display turn off after 60 sec.

psi bar kgf MPa

Port size

G1/8”(BSPP), M5

1 years (5 times/day)

Pressure unit

psi, bar, kgf/cm

2

 and MPa u

ser selectable

Back light

Yes

B. 

PANEL DESCRIPTION

*

Air tube must be installed to maintain IP65. (See section K)

0.01
0.01

0.1

-

0.001

-

Ø

 2mm MAX

www

.ar-vacuum.com

www

.ar-vacuum.com

www

.ar-vacuum.com

Отзывы: