![AR 350A400 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/ar/350a400/350a400_operating-and-service-manual_2962315036.webp)
Model 350A400
20
Rev B
2.4.6.8
RF Gain
Query to get the RF gain.
Syntax:
RFG?
Parameters:
None
Response Format:
RFG=<space>x<LF>
Where:
x
= 0000 to 0100
Example:
To find out the RF gain of the 350A400, send the following query:
RFG?<LF>
Response:
RFG=<space>0075<LF>
(75% Gain)
2.4.6.9
Faults
Query to find the faults that have occurred with the 350A400.
Syntax:
FSTA?
Parameters:
None
Response Format:
FSTA=<space>00xx
Where:
xx
=
0
to
17 (Hexadecimal)
Table 2-6. Faults
xx
Decimal
Description
00
0
No Fault
01
1
PS3
02
2
Interlock
03
3
PS1
04
4
PS2
05
5
Thermal A7
06
6
Thermal A6
07
7
Thermal A5
08
8
Thermal A4
09
9
Thermal A2
0A
10
Thermal PS2
0B
11
Thermal PS3
13
19
Amp A7
14
20
Amp A6
15
21
Amp A5
16
22
Amp A4
17
23
Amp A2
Example:
To find out what faults have occurred, send the following query.
FSTA?<LF>
Response:
FSTA= 0002<LF>
(Interlock fault)