![AR 10U1000 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/ar/10u1000/10u1000_operating-and-service-manual_2962303044.webp)
Model 10U1000
26
Rev B
4.3.7
Low or No Power Output (RF Test) (Schematic Diagram No.
10041189, 10043972)
NOTE: The DC Tests specified in Section 4.3.8 should be completed before conducting the RF tests specified
in the following sections.
1.
The Model 10U1000’s typical gain response at -20 dBm input and 0 dBm input is shown in Figure 4-1
and Figure 4-2. The actual gain may vary considerably from that shown in Figure 4-2 but should be
≥
40
dBm at 0dBm input.
Figure 4-1. Typical Response at -20dBm Input
Figure 4-2. Typical Response at 0 dBm Input