The Model DC7445 is a dual directional coupler with excellent frequency range and power handling 

capability. The wide range assures flexibility in coupling power amplifiers to receivers, network analyz-
ers, power meters, spectrum analyzers and other measuring instruments. The dual directional design 
allows the user to monitor both forward and reflected power, a much needed characteristic in RF sus-
ceptibility testing for amplifier overdrive protection, field control and load protection. Low insertion loss 
allows efficient coupling to the load. 
The Model DC7445 is intended for use with 250T6G18 and other T Series microwave TWT amplifiers. 
The export classification for this equipment is EAR99.  These commodities, technology or software are 
controlled for export in accordance with the U.S. Export Administration Regulations. Diversion contrary 

to U.S. law is prohibited.  

Features 

Specifications 

DC7445 

Dual Directional 
Coupler 



3000 Watts 



6GHz–18GHz 

 

AR RF/Microwave  
Instrumentation 
160 School House Rd 

Souderton, PA 18964 
215-723-8181 
 

For an applications engi-
neer call:800.933.8181

  

 

www.arworld.us 

 

 

To order AR Products, call 215.723.8181.  For an applications engineer call:800.933.8181. Direct to Service call: 215.723.0275 or  

email: 

[email protected]

  For Faxing Orders:866.859.0582 (Orders Only Please) 

[email protected]

 

Approved for public release by AR RF/Microwave Instrumentation 

081418 

Specifications 

FREQUENCY RANGE: 6 GHz–18 GHz 

POWER (Maximum): 3 kW CW, 16 kW peak 

COUPLING FACTOR: 48 dB ± 4 dB (includes flatness) 

COUPLING FLATNESS: ±3 dB 

DIRECTIVITY: Typical, 30 dB; Minimum, 20 dB 

INSERTION LOSS: 0.3 dB maximum 

VSWR (Main Line): 1.3:1maximum 

CONNECTORS: 
Main Line, WRD-650 
Coupled, Type N female 

WEIGHT: 0.64 kg (1.4 lbs) 

SIZE (WxH): 2.9 x 3.5 x 30.5 cm (1.13 x 1.4 x 12 in) 

EXPORT CLASSIFICATION: EAR99 

Содержание 10044292

Страница 1: ...Operating and Service Manual DC7445 Model 10044292 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Страница 2: ......

Страница 3: ...riction of the use of certain hazardous substances in electrical and electronic equipment recast RECYCLING WEEE DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on was...

Страница 4: ......

Страница 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Страница 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Страница 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Страница 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Страница 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Страница 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Страница 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Страница 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Страница 13: ...ns and connector locations Operation of the Model DC7445 is quite simple The input signal is fed into the WRD 650 waveguide flange J1 and the output is taken from the WRD 650 waveguide flange J2 Forwa...

Страница 14: ...Model DC7445 2 Rev...

Страница 15: ...Export Administration Regulations Diversion contrary to U S law is prohibited Features Specifications DC7445 Dual Directional Coupler 3000 Watts 6GHz 18GHz AR RF Microwave Instrumentation 160 School...

Страница 16: ......

Страница 17: ...Model DC7445 Rev 5 Drawing 10043879...

Страница 18: ...Model DC7445 6 Rev...

Страница 19: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Страница 20: ......

Отзывы: