![AR 10044005 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ar/10044005/10044005_operating-and-service-manual_2962284042.webp)
Model 5000A225A
28
Rev B
2.4.2.6.9
State
Query to find the state of the Model 5000A225A.
Syntax:
STATE?
Parameters:
None
Response Format:
STATE=<space>xyza<LF>
Where:
x, y, z
, and
a
are each an ASCII character representing a hexadecimal character.
They can be 0 to 9 or A to F.
Each hexadecimal character represents a 4-bit binary number. This 4-bit number is a bit
pattern which contains information about the state of the Model 5000A225A. The
definitions of these bit positions can be found in the table below.
NOTE: Bits labeled NOT USED may be read as a bit state of 1 or 0
Table 2-6. Bit Position
BIT STATE
BIT
POSITION
BIT DESCRIPTION
0
1
NOTES:
x
0
PULSE STATUS
OFF
PULSE
1
(NOT USED)
2
(NOT USED)
3
REMOTE CONTROL
DISABLED
ENABLED
Response to key-switch
position
y
0
POWER STATUS
OFF
POWER ON
1
STANDBY STATUS
OFF
STANDBY
Also known as RF OFF
2
OPERATE STATUS
OFF
OPERATE
Also known as RF ON
3
FAULT STATUS
OFF
FAULT
EXISTS
z
0
KEYLOCK INHIBIT
OFF
INHIBITED
Response to key-switch
position
1
ALC ALERT
OK
FOLD BACK
ALC fold back indication
2
RF AUTO BIASING
INACTIVE
ACTIVE
Biasing state
3
(NOT USED)
a
0
MODE MANUAL
DISABLED
ENABLED
Also known as CW MODE
1
(NOT USED)
2
MODE ALC INTERNAL
DISABLED
ENABLED
3
(NOT USED)
Example:
To read the state, send the following query.
STATE?<LF>
Response:
STATE=<space>8301<LF>
(Remote Mode, Power On, RF OFF, and Manual Mode)