Model 4000TP2G4
Rev A
23
3.7 REMOTE IEEE-488 OPERATION
The TWTA is provided with an IEEE-488 interface that permits remote emulation of OPERATE,
STANDBY, and RESET push-buttons as well as access to parameter measurements, system faults, gain
adjustment and control unit status. The following tables summarize the commands and the return codes.
Table 3-3. Catalog of IEEE-488 Commands
Command
Function
Units Response format
RDSTAT
Returns status code of processing of previous command (see
Table 3-4)
STATUS=[ ]
RDFLT
Returns system fault code (see Table 3-5)
flt=[ ]
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
SYSTEM:ON;
Emulates pressing the System ON button from System OFF
(Exit Sleep Mode)
SYSTEM:OFF;
Emulates pressing the Power Save button. (Enter Sleep
Mode)
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK1
Returns cathode voltage, HPA1
KV
Ek=[ ]
RDEK2
Returns cathode voltage, HPA2
KV
Ek=[ ]
RDEB1
Returns collector voltage, HPA1
KV
Eb=[ ]
RDEB2
Returns collector voltage, HPA2
KV
Eb=[ ]
RDEG1
Return grid voltage, HPA1
V
Eg=[ ]
RDEG2
Return grid voltage, HPA2
V
Eg=[ ]
RDEF1
Returns heater voltage, HPA1
V
Ef=[ ]
RDEF2
Returns heater voltage, HPA2
V
Ef=[ ]
RDIF1
Returns heater current, HPA1
A
If=[ ]
RDIF2
Returns heater current, HPA2
A
If=[ ]
RDIW1
Returns helix current, HPA1
mA
Iw=[ ]
RDIW2
Returns helix current, HPA2
mA
Iw=[ ]
RDTMPTWTHPA1F
Returns TWT temp (°F), HPA1
°F
TWTHPA1F=[ ]F
RDTMPTWTHPA2F
Returns TWT temp (°F), HPA2
°F
TWT HPA2F=[ ]F
RDTMPTWTHPA1C
Returns TWT temp (°C), HPA1
°C
TWTHPA1C=[ ]C
RDTMPTWTHPA2C
Returns TWT temp (°C), HPA2
°C
TWTHPA2C=[ ]C
RDTMPPSHPA1F
Returns power supply temp (°F), HPA1
°F
PSHPA1F=[ ]F
RDTMPPSHPA2F
Returns power supply temp (°F), HPA2
°F
PSHPA2F=[ ]F
RDTMPPSHPA1C
Returns power supply temp (°C), HPA1
°C
PSHPA1C=[ ]C
RDTMPPSHPA2C
Returns power supply temp (°C), HPA2
°C
PSHPA2C=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
Содержание 10031732
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 16: ......
Страница 18: ......
Страница 26: ......
Страница 39: ...Model 4000TP2G4 Rev A 17 Figure 3 3 Menu Tree ...
Страница 56: ...Model 4000TP2G4 34 Rev A ...
Страница 58: ...Model 4000TP2G4 36 Rev A ...
Страница 60: ...Model 4000TP2G4 38 Rev A ...
Страница 62: ......