Models 200T18G26z5A/200T26z5G40A
Rev –
25
unit. Thus, users should reduce the likelihood of occurrence of this problem by limiting the amount of time
in the Standby mode.
The service measures involve pulsing of the tube beam current and gradually increasing the duty of the
pulsing until the unit will operate continuously. Note that a similar condition can exist for tubes with grids
when the TWTA is in the Operate mode (high voltage is on) but gating (control) input is set so that the grid
turns off the TWT beam current. Operational procedures should also limit the time in this mode.