MODEL DC6380, M1, M2 

DUAL DIRECTIONAL COUPLER 

3000/4500/7000 WATTS CW 

80 - 1000 MHz 

 
The Model DC6380 is a dual directional coupler with excellent frequency range and power handling 
capability. The wide range assures flexibility in coupling high power amplifiers to oscilloscopes, voltmeters, 
power meters, spectrum analyzers and other measuring instruments. The dual directional design allows the 
user to monitor both forward and reflected power, a much needed characteristic in RF susceptibility testing for 
amplifier overdrive protection, field control and load protection. Low insertion loss allows efficient coupling to 
the load while the coupling factor is well matched to typical laboratory equipment. 

 

The DC6380 series is ideally suited for use with the AR Worldwide Model 2000W1000A, 3000W1000A, 
4000W1000A and other high power amplifiers in this frequency range. 
 

SPECIFICATIONS, DC6380 

 

Frequency Range ..........................................................80 - 1000 MHz 

 

Power (Maximum) (Infinite VSWR)...................................See Model Configuration 
 

(50 ohms, 1.0:1 VSWR) ..........................................7000 watts cw 

 

10,000 watts peak 

 

Coupling Factor ............................................................See Model Configuration 

 

Coupling Flatness .........................................................± 1.0 dB 

 

Directivity......................................................................25 dB typical 
 20 

dB 

minimum 

 

Insertion Loss ................................................................0.15 dB maximum 

 

Impedance (Main Line)..................................................50 ohms VSWR 1.5:1 maximum 

 

Connectors 
 Mainline ................................................................EIA Flange 1 

5

/

8

 inch male 

 Coupled ................................................................N 

female 

 

Weight (Maximum)........................................................1.8 kg 
 4.0 

lb 

 

Size (W x H x D) ............................................................20.3 x 8.9 x 10.2 cm 
 

8.0 x 3.5 x 4.0 in 

 

Model Configuration 

Model Number 

Coupling Factor 

Power (cw/peak) 

DC6380 

65 ± 1.5 dB 

3000 watts/6000 watts 

DC6380M1 

68 ± 1.5 dB 

4500 watts/9000 watts 

DC6380M2 

70 ± 1.5 dB 

7000 watts/10,000 watts 

 

 

Содержание 10008784

Страница 1: ...Operating and Service Manual DC6380 Model 10008784 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Страница 2: ......

Страница 3: ...riction of the use of certain hazardous substances in electrical and electronic equipment recast RECYCLING WEEE DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on was...

Страница 4: ......

Страница 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Страница 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Страница 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Страница 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Страница 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Страница 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Страница 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Страница 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Страница 13: ...Model DC6380 is quite simple The input signal is fed into the jack J1 marked INPUT and the output is taken from the jack J2 marked OUTPUT The input and output jacks on the unit are Type EIA 5 16 inch...

Страница 14: ...Model DC6380 2 Rev...

Страница 15: ...t coupling to the load while the coupling factor is well matched to typical laboratory equipment The DC6380 series is ideally suited for use with the AR Worldwide Model 2000W1000A 3000W1000A 4000W1000...

Страница 16: ......

Страница 17: ...Model DC6380 Rev 5...

Страница 18: ...Model DC6380 6 Rev...

Страница 19: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Страница 20: ......

Отзывы: