background image

15         Changing the water and refilling the tank

1

2

The  water  in  the  closed  400  ml  tank  of  the  device  serves  to 

keep  the  sponge  permanently  moisturized  and  is  gradually 

consumed by electrolysis. As soon as the 

water drop signal

 (1) 

or  (2)  starts  to  flash,  the  tank  must  be  refilled.  The  fuel  cap 

opens  by  turning  it  to  the  left! 

Filtration  through  the  filter  can 

take  up  to  10  minutes

.  It  is  best  to  use  distilled  or  reverse 

osmosis  water  (steam  iron  water).  Make  sure  that  the  tank 

does  not  overflow  because  leaking  water  could  damage 

electronic  components.  After  refilling  the  warning  light  should 

go out and the re-inserted sponge should be well moistened in 

the water. 

If you are transporting the Lourdes or do not want to use it for 

more than a week (holidays etc.) you should change the tank 

water (and of course the water in the jug) before the next time 

it is used.  

To empty the tank

, first remove the jug and sponge holder with 

the sponge. Unplug the power plug. Then open the tank cap 

and place the unit over a water spout. Finally, pull the plug of 

the drainage hole and drain the water. 

Attention:

  During  the  procedure,  make  sure  that  you  do  not 

lose the sponge or the very small drainage plug and replace it 

after emptying. 

Содержание Lourdes

Страница 1: ...Karl Heinz Asenbaum USER MANUAL Hydrogen Water Generator Lourdes...

Страница 2: ...delivery Model D and F 08 Overview Model D 09 Overview Model F 10 Understanding the Lourdes 11 Preparation for use 12 Producing hydrogen water 13 Checking hydrogen water 14 Hygiene water 15 Water tan...

Страница 3: ...ch has bonded as energy less water in our oceans Water H2O is hydrogen gas H2 which has been combusted by oxygen This occurs for example with sugar which is converted from food into energy So hydrogen...

Страница 4: ...0 5 mg per day accepted by most scientists when drinking 0 33 liters daily Even if one may believe the most optimistic statement about the holy water in the Lourdes pilgrim site although it is scienti...

Страница 5: ...uced primarily with stationary electrolytic water ionizers Depending on the design these hydrogen values reach from 0 5 to 2 8 mg L in the flow process and at the same time increase the pH value The L...

Страница 6: ...ing agents Never drop the device Preferably use cold water under 20 C Never place the device in direct sunlight or subject it to temperatures under 0 degrees or over 50 degrees Celsius Stop the device...

Страница 7: ...ur mains voltage Read this user manual before operating the device If you are unsure about anything please consult your supplier before using the device If more people will use the device they should...

Страница 8: ...ay Tankverschluss R ckenansicht Tankablauf Buchse f r DC Netzteil Geh use der Bedieneinheit Schalter f r Hygiene Wasser Back view Tank drain Socket for DC power supply Housing for control unit Switch...

Страница 9: ...Cap with float gauge Gliding bar for float gauge Glass cylinder with electrolysis unit Tank for anode water Float gauge Front view Operating unit Cylinder contact sensor Back view Socket for DC power...

Страница 10: ...for this Water ionizer Both electrodes in water away from the membrane The membrane has large pores The hydrogen water above becomes alkaline below acidic Lourdes Both electrodes in the water directl...

Страница 11: ...nk and screw its lid back on This water is for electrolysis only and is not to be drunk You should use mineral poor clean water such as distilled water for irons or reverse osmosis water 5 Wait until...

Страница 12: ...ng rod 3 which catches the hydrogen bubbles below the water surface before they gas out So these have more time to dissolve in the water The disc must always be well below the water surface 3 To start...

Страница 13: ...ount With the Lourdes Hydrogen Generator depending on the production time amount of water type of water air pressure and temperature can a hydrogen water be produced with 300 to 1200 ppb 0 3 to 1 2 pp...

Страница 14: ...utton For model D press the button O Cleaning Thereupon if the display color changes to red oxygen and ozone bubbles are now rising in the device and on the right side of the display above the O the r...

Страница 15: ...water could damage electronic components After refilling the warning light should go out and the re inserted sponge should be well moistened in the water If you are transporting the Lourdes or do not...

Страница 16: ...C water The citric acid solution should be allowed to act for 1 hour and then rinse the container and the electrode several times with warm water Important The platinized electrodes adhere directly to...

Страница 17: ...the electrodes in the jug then no longer get power The contacts on the bottom of the glass jug should also be wiped off gently if they are dirty or rusty Attention Never touch the electrodes or the me...

Страница 18: ...er Power supply AC 100 240 V 50 60 Hz Output DC 24 V 1A 1 2 A Problem Please check Solution Lights don t shine Electricity failure Cable connected at both ends Cable damaged Check electricity mains Co...

Страница 19: ...k empty Refill tank P 15 Water leaks out of the device or base Unplug the device Device must be repaired Low bubble formation Brand new jug Rust on the contact pins Full capacity after 2 hours Gently...

Страница 20: ...free disposal or recycling Please don t pollute your environment Many of the parts of this high end device can be used again EXCLUSION OF LIABILITY Molecular Hydrogen is a naturally and continually oc...

Отзывы: