background image

22 - 26 

IsACQ455C-0 (ENG) Rev. 261108-0

Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403  

Fax: +39 0522 494410 http:\\www.aquatronica.com E-mail: [email protected]

(Fig. 42)

Would you like to modify 

or delete?

Modify

Delete

(Fig. 44)

Would you like to 

delete all?

Enter: Confirm

Esc: Cancel

(Fig. 43)

Would you like to 

delete 

this program?

Enter: Confirm

Esc: Cancel

Show/Modify/Delete

In  this  menu  you  can  view  (Show),  edit  (Modify)  or 

delete (Delete) the programs entered. 

Proceed as follow to use this function:

 

Access the program that you wish to edit or delete by 

pressing “Enter” on “Show/Modify/Delete”.

• Scroll using the right/left arrow keys 



 until you 

reach the program required.

• Press “Enter” and the specific screen page appears 

on the display (Fig. 42).

•  Select  the  “Modify”  box  using  the  up/down  arrow 

keys 



 to edit the program, change the parameters 

required and press “Enter” to confirm the modification 

made.

• Select the “Delete” box using the up/down arrow keys 



 to delete the program. The cancellation screen page 

will appear (Fig. 43); press “Enter” to delete or “Esc” 

to cancel the procedure.

Delete all (Fig. 44)

This function can be used in a number of menus because 

the program deleting method is always the same.

In this menu you can simultaneously delete all the pro-

grams entered in the menu in which you are working.

Proceed as follow to use this function:

• Select the “Delete all” box using the up/down arrow 

keys 



  and  press  “Enter”;  the  cancellation  screen 

page will appear (Fig. 44); press “Enter” to delete or 

“Esc” to cancel the procedure.

About 

Provides  information  on  the  control  unit’s  firmware 

version.

Editing/deleting the Programs

(Fig. 41)

Programs

Insert

Show/Modify/Delete

Delete all

Impostazioni

Centro Messaggi

Cambia PIN

(Fig. 45)

Aquatronica

 FW version: x.y

Press a key 

to continue

Содержание ACQ455

Страница 1: ...Instruction manual Cod ACQ455 KORALIA WAVE MODULE ...

Страница 2: ...5 Description of the parts of the Koralia Wave Module Page 6 First time connection of the Koralia Wave Module Page 7 Main menu Page 8 Manual controls menu Page 9 Programs menu Page 10 Examples of simple programs Page 12 Examples of composite programs Page 20 Editing deleting programs Page 22 Guarantee certificate Page 23 Declaration of conformity Page 24 Technical data Page 25 CHECK OUT OUR WEBSIT...

Страница 3: ...Directives 2002 95 CE 2002 96 CE and 2003 108 CE related to the reduc tion in the use of hazardous compounds in electrical and electronic equipment as well as waste disposal The symbol of the crossed out dustbin means that the product must be disposed of separately from other waste at the end of its useful life The user must therefore hand it over to suitable recycling centres for electronic and e...

Страница 4: ...authorised centres by qualified personnel The manufacturer is not liable for personal injuries or material damages caused by tampering with the product Only original AQUATRONICA accessories or accessories approved by the same may be connected to the product The use of unapproved accessories could cause damages fires electric shocks or injuries to people Keep the product out of children s reach to ...

Страница 5: ... 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com 6 5 4 1 2 3 Package contents The package contains 1 1 Koralia Wave Module 2 1 BUS cable 3 1 Power supply lead 4 1 Ferrite accessory 5 1 Ferrite accessory opening key 6 1 Quick installation guide ...

Страница 6: ... 3 4 1 4 5 6 7 Description of the parts of the Koralia Wave Module 1 Blue indicator LEDs that point out the operating status and the power of the pumps 2 BUS connector for connecting to the Aquarium Controller System 3 Jack for connecting the luminosity sensor optional 4 Connectors for the 12 Volt Koralia pumps 5 On OFF button 6 Socket for the power supply lead 7 Cooling fan ...

Страница 7: ...oralia pumps as illustrated below 4 Connect the Koralia pumps to be piloted to the dedicated sockets 5 Switch the Koralia Wave Module on by switching the ON OFF switch at the back of the device from position 0 Off to position I On INITIALISATION PROCEDURE Once the Koralia Wave Module has been switched on the pumps connected to it start up quickly one after the other P1 P2 P3 and P4 reaching their ...

Страница 8: ... the up down arrow keys and press Enter Fig 4 Select the Dimmer pumps menu using the up down arrow keys and press Enter Fig 5 Select the letter to be entered using the up down arrow keys and use the right left arrow keys to move within the word upon completion press Enter Proceed as follows to change the name of the individual Koralia pump Select the Single pumps menu using the up down arrow keys ...

Страница 9: ...menu Dimmer pumps Manual controls All at maximum Select the All at maximum function using the up down arrow keys and press Enter Manual controls All off Fig 10 Used to switch all the pumps off simultaneously Proceed as follow to use this function Main screen page Main menu Dimmer pumps Manual controls All off Select the All off function using the up down ar row keys and press Enter Manual controls...

Страница 10: ...ys and select enter pump by pressing the Enter key The screen page appears in which you can choose on which pump you wish to work and define its operating parameters Fig 16 Use the right left arrow keys to move within the screen page and the up down arrow keys to change selection Fig 15 From 00 00 To 24 00 Enter pump Fig 14 Programs P1 Next Minimum power 30 Maximum power 100 Up T 00h 00m 00s Max T...

Страница 11: ... same time as the previous one You just need to define the minimum and maximum power of the pump because the times defined in points 5 6 7 are the same as the previous pump Added The pump starts to reach its maximum power as soon the previous pump has reached its maximum power The pump reaches the minimum power set when the previous pump starts to slow down You need to define the minimum and maxim...

Страница 12: ...tronica com 1 2 4 3 P1 P2 P4 P3 P1 P2 P3 P4 Examples of simple programs From 00 00 To 24 00 P1 P2 P3 P4 Supposing you wish to create the effects in the water using 4 pumps you can obtain differ ent effects based on how you set the Relation with the previous pump function described on Page 11 for each pump in the program 1 Example of SEQUENTIAL PROGRAMMING Fig 17 ...

Страница 13: ...mum power 100 Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Fig 18 Fig 19 Fig 20 Fig 21 Enter the second pump with the following parameters Enter the third pump with the following parameters Enter the fourth pump with the followin...

Страница 14: ...20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com P1 P2 P3 P4 1 2 1 2 P1 P2 P4 P3 Examples of Simple Programs 2 Example of ALTERNATED PROGRAMMING Fig 22 From 00 00 To 24 00 P1 P2 P3 P4 ...

Страница 15: ...00 Up T 00h 00m 10s Max T 00h 00m 05s Down T 00h 00m 10s Up T 00h 00m 10s Max T 00h 00m 05s Down T 00h 00m 10s Fig 23 Fig 25 Examples of Simple Programs P2 P4 Same Minimum power 30 Maximum power 100 Same Minimum power 30 Maximum power 100 Fig 24 Fig 26 Set the minimum power maximum power Up T Max T and Down T as required Set the minimum power maximum power Up T Max T and Down T as required Set the...

Страница 16: ...ia 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com P1 P2 P3 P4 3 4 1 2 P1 P4 P3 P2 3 Example of Added PROGRAMMING Fig 27 From 00 00 To 24 00 P1 P2 P3 P4 Examples of Simple Programs ...

Страница 17: ...mmer pumps Programs Enter In the From To box set the time in which the program is to be activated Enter the first pump with the following parameters P1 Next Minimum power 30 Maximum power 100 Up T 00h 00m 05s Max T 00h 00m 10s Down T 00h 00m 05s Fig 28 Set the minimum power maximum power Up T Max T and Down T as required Set the minimum power maximum power and max T as required Set the minimum pow...

Страница 18: ...ndustria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com P1 P2 P3 1 2 1 P1 P3 P2 4 Example of MIXED PROGRAMMING Fig 32 Example of Simple Programs From 00 00 To 24 00 P1 P3 P2 ...

Страница 19: ...he first pump with the following parameters P1 P2 Next Minimum power 30 Maximum power 100 Next Minimum power 30 Maximum power 100 Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Up T 04h 00m 05s Max T 00h 00m 03s Down T 04h 00m 05s Fig 33 Fig 35 P3 Same Minimum power 30 Maximum power 100 Fig 34 Set the minimum power maximum power Up T Max T and Down T as required Set the minimum power maximu...

Страница 20: ...r that allow the same pumps to work differently based on the time schedule An example of this type of application entails the use of three pumps positioned in three corners of the tank where the two side pumps simulate a dimmered wave effect repeated throughout the duration of the light period while the third pump situated in the centre increases its power progressively reaching maximum power duri...

Страница 21: ...first pump with the following parameters P1 P2 Next Minimum power 30 Maximum power 100 Next Minimum power 30 Maximum power 100 Up T 00h 00m 05s Max T 00h 00m 03s Down T 00h 00m 05s Up T 04h 00m 05s Max T 00h 10m 03s Down T 04h 00m 05s Fig 38 Fig 40 Set the minimum power maximum power Up T Max T and Down T as required Set the minimum power maximum power Up T Max T and Down T as required Set the min...

Страница 22: ... down arrow keys to edit the program change the parameters required and press Enter to confirm the modification made Select the Delete box using the up down arrow keys to delete the program The cancellation screen page will appear Fig 43 press Enter to delete or Esc to cancel the procedure Delete all Fig 44 This function can be used in a number of menus because the program deleting method is alway...

Страница 23: ... of purchase only upon presentation of this certificate which must bear the shop s invoice or receipt where the serial numbers of the products installed are written Lacking such information the end customer will be offered a guarantee of 24 months from the date printed on the back of the product AQUATRONICA may refuse to acknowledge the guarantee if such information is incomplete or has been alter...

Страница 24: ...24 26 IsACQ455C 0 ENG Rev 261108 0 Via dell Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Declaration of Conformity ...

Страница 25: ...Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Technical data Koralia Wave Module 230V 240V 50Hz MAX 1 20A 115V 60Hz MAX 2 20A Dimensions 220 L x 150 W x 80 H mm ...

Страница 26: ...Una divisione di A E B S r l v dell Industria 20 42025 Cavriago RE ITALY Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com ...

Отзывы: