![Aquatronica ACQ210-D Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/aquatronica/acq210-d/acq210-d_instruction-manual_2961988008.webp)
IsACQ210D-0 Rev. 250907-2
8 - 16
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Fax: +39 0522 494410 http:\\www.aquatronica.com E-mail: [email protected]
Data Record
The Data Record graphically displays variations in the
conductivity (density) during the previous 24 hours with
a minimum interval of 30 minutes (Ex. Fig. 13).
To display the data, proceed as follows:
Main screen
Main menu
Density
Data Record.
•
Using the
keys, select the maximum (MAX), mini
-
mum (MIN) or current conductivity (density). Using the
keys, move within the chart to view the conductivity
of a given time. Press “
Enter
” when finished.
Alarm
A visual or acoustic alarm can be set to notify the user
if the conductivity level goes below or above the “
Less
than
” or “
Greater than
” values (Ex. Fig. 14).
If the conductivity value exceeds these limits, the con
-
ductivity value on the main screen will blink if the alarm
is set to “
No Sound
”.
If the alarm is set to “
Sound
”, the value will blink, an
acoustic signal will sound and the
icon will appear
on the main screen.
To program this function, proceed as follows:
Main screen
Main menu
Density
Alarm.
•
Select the desired option using the
keys:
OFF =
alarm disabled
Sound =
alarm and acoustic signal enabled
No Sound =
alarm enabled and acoustic signal disa
-
bled
•
Select “
Less than
” using the
keys and then
“
Greater than
” and with the
keys program the
desired conductivity to set the limits beyond which the
alarm will be enabled.
After programming the various settings, press “
En-
ter
”.
English
Current value
11/06 9:30 1.0232
(Fig. 13)
(Fig. 14)
Alarm
OFF
Less than: 1.0220
Greater than: 1.0260