background image

3

GENERAL INFORMATION

• Clean a new pool as well as possible before filling pool and operating filter.

Excess dirt and large particles of foreign matter in the system can cause seri-
ous damage to the filter and pump.

• With a permanent media filter in place and operating correctly, clean water

is returned to the pool faster than pool water is being contaminated. A typi-
cal pool installation will require approximately one week to obtain and
maintain the sparkle that your filter is capable of giving you.

• Maximum pressure is 50 PSI (345 kPa). DO NOT connect the filter to a city

water system or to an individual water well system.

Hazardous pressure. Open air release valve to vent all air

from system before operating  system. NEVER operate filter with air
trapped inside.

• Th AquaTools

TM 

permanent media filter is designed to filter water for swim-

ming pools and spas. On a new installation, we recommend:

1. Disassemble the filter after the initial cleanup.

Hazardous pressure. 

To prevent severe injury or major prop-

erty damage, exactly follow "Filter Disassembly/Assembly Procedure" on
Pages 6 and 7.

2. Remove and hose down the element assembly to remove contaminants.

• Maintain pool water pH between 7.2 and 7.6.

• Make sure that internal air bleed tube and filter are clean and installed prop-

erly at top of module before operating filter.

• Make sure that Safe-Lok™ Ring is securely locked in place before operating

filter.

• Maintain pressure gauge in good working order. Replace a damaged gauge

immediately.

• Cleaning interval is based on pressure rise, not on length of time filter is op-

erated. Different water conditions will have different normal cleaning inter-
vals. 

• Check local codes for restrictions on waste water disposal requirements.

NOTICE:

Some pool disinfectants may clog filter module. To maximize

module life and filter cycle time, closely follow disinfectant manufacturer’s
instructions when cleaning pool or filter.

Owner’s Information

Serial Number ____________________________________________________

Dealer ___________________________________________________________

Dealer’s Telephone #_______________________________________________

Purchase Date ____________________________________________________

Installation Date ___________________________________________________

Pressure Gauge Reading at Startup ___________________________________

When to Clean the Filter

The filter module should normally be
cleaned when the pressure gauge reading
increases 10 PSI over the start-up pressure
(record the start-up pressure under
“Owner’s Information”, below, right).
In some pools, accessories such as foun-
tains or pool cleaners may be noticeably
affected by the normal decrease in flow as
the filter becomes dirty. If so, clean the fil-
ter more frequently (that is, at a pressure
increase of less than 10 PSI) in order to
maintain the required flow.

H

ea
d

Bo

dy

F

o

re

A

rm

Up

per

Arm

Le

g J

oin

t

Leg Joint

Leg Joint

Head

Body

WARNING

Risk of drowning and
falls. Place equipment 
at least 4 feet from pool 
so that children cannot
climb over it into pool.

sss

Do not allow children
to stand or play on filter
or pump.

Содержание AT84100

Страница 1: ...752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 Union City TN Delavan WI Mississauga Ont Murrieta CA 2003 Printed in U S A AT338 Rev 2 3 03 This manual should b...

Страница 2: ...urce of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system be fore operating or testing equipment Before...

Страница 3: ...order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is op erated Different water conditions will have different normal cleaning inter va...

Страница 4: ...120 454 140 529 160 606 Flow in Gallons Per Minute LPM 20 138 150 568 SPECIFICATIONS FIGURE 1A Dimensions in inches mm Table 1 Filter Specifications Model No AT84100 AT84150 Filter Area sq ft m2 100 9...

Страница 5: ...he most convenient piping run After you have piped the inlet and drain apply the inlet decal to the port to which you have run the inlet piping For ease of maintenance use AquaTools union couplings to...

Страница 6: ...e until it locks behind the safety latch see Figure 3 E If the ring was already locked remove it and the upper tank shell Inspect and clean the O ring and all sealing surfaces Re lubricate the O ring...

Страница 7: ...the bottom of the filter cartridge over the tank outlet port Push down firmly to seal 3 Ensure that the air bleed assembly on top of the module is clean and prop erly mounted NOTICE Lubricate O ring...

Страница 8: ...ns of this manual Special Cleaning Instructions Use this procedure to clean scale or oils which are not removed by hosing down module Be sure to dispose of spent chemicals according to all applica ble...

Страница 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Страница 10: ...d 8 B Water is chemically out of balance consult pool professional C Excessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed filter in module assembly with a h...

Страница 11: ...ring 1 35505 1424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 11 Air bleed assembly 1 24800 0121 12 Filter module AT84100 1 27002 0100S 12 Filter module AT84150 1 27002 0150S 1...

Страница 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...

Отзывы: