• Clean a new pool as well as possible before filling pool and operating filter.

Excess dirt and large particles of foreign matter in the system can cause seri-
ous damage to the filter and pump.

• With a modular Diatomaceous Earth (DE) filter in place and operating cor-

rectly, clean water is returned to the pool faster than pool water is being
contaminated. A typical pool installation will require approximately one
week to obtain and maintain the sparkle that your filter is capable of giving
you.

• Do not use more than the recommended amount of DE in your filter. Excess

DE can cause a buildup of DE and “bridging” between the pleats which will
plug the filter.

• Maximum pressure is 50 PSI (345 kPa). DO NOT connect the filter to a city

water system or to an individual water well system.

Hazardous pressure. Open air release valve to vent all air

from system before operating  system. NEVER operate filter with air
trapped inside.

• The AquaTools

TM

modular DE filter is designed to filter water for swimming

pools. On a new pool installation, we recommend:

1.Disassemble the filter after the initial cleanup.

Hazardous pressure. 

To prevent severe injury or major prop-

erty damage, exactly follow "Filter  Disassembly/Assembly Procedure" on
Pages 6 and 7.

2.Remove and hose down the element assembly to remove spent DE and 

contaminants.

• Maintain pool water pH between 7.2 and 7.6.
• Make sure that internal air bleed tube and filter are clean and installed prop-

erly at top of module before operating filter.

• Make sure that Posi-Lok™ Ring is securely locked in place before operating

filter.

• Maintain pressure gauge in good working order. Replace a damaged gauge

immediately.

• Cleaning interval is based on pressure rise, not on length of time filter is 

operated. Different water conditions will have different normal cleaning 
intervals. 

• Check local codes for restrictions on waste water and DE disposal require-

ments.

NOTICE:

Some pool disinfectants may clog filter module. To maximize

module life and filter cycle time, closely follow disinfectant manufacturer’s
instructions when cleaning pool or filter (see Page 8).

Owner’s Information

Serial Number ____________________________________________________

Dealer ___________________________________________________________

Dealer’s Telephone #_______________________________________________

Purchase Date ____________________________________________________

Installation Date ___________________________________________________

Pressure Gauge Reading at Startup ___________________________________

When to Clean the Filter

The filter module should normally be
cleaned when the pressure gauge reading
increases 10 PSI over the start-up pressure
(record the start-up pressure under
“Owner’s Information”, below, right).
In some pools, accessories such as foun-
tains or pool cleaners may be noticeably
affected by the normal decrease in flow as
the filter becomes dirty. If so, clean the fil-
ter more frequently (that is, at a pressure
increase of less than 10 PSI) in order to
maintain the required flow.

H

ea
d

Bo

dy

F

o

re

A

rm

Up

per

Arm

Le

g J

oin

t

Leg Joint

Leg Joint

Head

Body

WARNING

Risk of drowning and
falls. Place equipment 
at least 4 feet from pool 
so that children cannot
climb over it into pool.

sss

Do not allow children
to stand or play on filter
or pump.

Содержание AT8230

Страница 1: ...erica 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 2002 Printed in U S A AT339 Rev 4 30 02 This manual should be furnished to the end user of this filter...

Страница 2: ...ternal source of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment...

Страница 3: ...locked in place before operating filter Maintain pressure gauge in good working order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is o...

Страница 4: ...PLD70 AT8230 AT8236 Table 1 Recommended DE Manufacturers Johns Manville Celite 545 GREFCO Inc Decalite 4200 Eagle Picher Minerals Inc Celatom Table 2 Filter Specifications AT8230 AT8236 Filter Area sq...

Страница 5: ...plastic pipe it will cause the pipe to crack Do not use sealant on unions assemble them dry and hand tight Support pipe independently to prevent strains on filter Fittings restrict flow for best effic...

Страница 6: ...nd the upper tank shell Inspect and clean the O ring and all sealing surfaces Relubricate the O ring NOTICE Lubricate O ring only with the silicone grease provided or equiva lent as other lubricants m...

Страница 7: ...lows 1 Press down on the small catch behind the safety latch and press or tap the latch out of the Tee slot in the tank see Figure 7 2 Snap the new latch into position NOTICE DO NOT operate the filter...

Страница 8: ...down module Be sure to dispose of spent chemicals according to all applica ble codes and waste disposal ordinances Use a soft stream nozzle to minimize flying water and spray Risk of fire or explosio...

Страница 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Страница 10: ...thoroughly see Page 8 C Water is chemically out of balance consult pool professional D Excessive air in filter non precoated areas may plug Vent air from tank and check for pump suc tion pipe leaks C...

Страница 11: ...424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 10A Pressure gauge screen 1 WC8 72D 11 Air bleed assembly 1 24800 0122 12 Filter module AT8230 1 27002 0030S 12 Filter module AT...

Страница 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...

Отзывы: