INSTALLING THE CARTRIDGES
Step 1
– Use the Canister Wrench in a clockwise direction
to gain access to the Sediment and Carbon Cartridges.
The Sediment Cartridge must be on the right and the
Carbon Cartridge on the left for proper operation.
IMPORTANT!
Flush Carbon Cartridge prior to installing
the RO Membrane.
Step 2
– Reattach the Canisters to the housing.
Step 3
– Flush the Carbon Cartridge. Prior to installing the
Membrane, it is important to flush any carbon dust from
the Carbon Cartridge. With only the Sediment and Carbon
Cartridges installed, allow water to run through the RO unit
until it runs clear.
Step 4 –
Install the Membrane. Remove the yellow tubing
connect to the Membrane Cap and use the Membrane
Wrench to remove the Cap.
Step 5 –
Remove the protective wrap from the RO
Membrane and insert into the Membrane Housing.
Step 6 –
Install the Membrane Cap and tighten with
the Membrane Wrench. Re-attach the yellow tubing
to the elbow on the Membrane Cap.
NOTE:
Use care to center the cartridges in the middle
of each Canister prior to re-attaching the Canisters.
The Carbon Cartridge will have gasket on each end
of the cartridge that must be properly seated.
NOTE:
It is important
to push the Membrane
completely into the
Membrane Housing
for the unit to function