background image

Relax Pro Bathtub

Operating Manual

Aquaticausa.com
Aquaticabath.ca
E: [email protected]

Important! Save these instructions!

NOTICE:  Follow all local plumbing and electrical codes.

Install to permit access for servicing.

A green with yellow stripe lead wire is provided within the wiring

compartment.  To  reduce  the  risk  of  electrical  shock,  connect

this  wire  to  the  grounding  terminal  of  your  electric  service  or

supply  panel  with  copper  wire  equivalent  in  size  to  the  circuit

conductor supplying this equipment. A pressure wire connector

is  provided  on  the  exterior  of  the  pump  or  control  within  this

unit  to permit connection  of a bonding conductor  between this

unit  and  all  other  exposed  metal  in  the  vicinity,  as  needed  to

comply with local requirements.

Grounding  is  mandatory. 

The  unit  must  be  installed  by  a

qualied  service  representative,  and  grounded.  Building

materials  and  wiring  should  be  routed  away  from  the  pump

body and other heat-producing components of the unit.

WARNING:    When  using  electrical  products,  basic

precautions  should  always  be    followed,  including  the

following:

DANGER:    Risk  of  electric  shock.  Connect  only  to  a

circuit  protected  by  a  Ground-Fault  Circuit-Interrupter

(GFCI).

WARNING:      Risk  of  electric  shock.  A  licensed

electrician should make all electrical connections.

WARNING:    Risk of electric shock. Disconnect power

before servicing.

WARNING:    Risk of injury or property damage. Please

read  all  instructions  thoroughly  before  beginning

installation, including the following requirements.

Important Product Information

Product Notices

WARNING:    Unauthorized  modification  may  cause  unsafe

operation and poor perfomance of the bath. Do not relocate the

pump, or make other modifications to the circulating system, as

this could adversely affect the performance and safe operation

of  your  bath. Aquatica Plumbing Group Inc.  shall not be  liable

under  its  warranty  or  otherwise  for  personal  injury  or  damage

caused by any such unauthorized modification.

Product Inspection

Carefully  unpack  the  product  and  inspect  the  unit  for  damage.

Return  the  unit  to  the  carton  during  construction  to  prevent

damage.

Factory-Assembled Features

Factory  installed  components  include  components  like  pump,

blower,  level  sensors,  in-line  heater,  submerged  chromatherapy

lights,  keypad  and  diverter.  The  pump  and  piping  are  factory-

assembled.

Connections and Service Access

NOTICE:  For  built-in  and  corner  bathtubs  provide  unrestricted

service  access  to  the  pump,  heater  and  control  box.  Provide

unrestricted  service  access  to  the  pump,  blower,  in-line  heater,

adjustable  feet,  and  control  box.  For  built-in  bathtubs  you  must

construct  an  access  panel  to  provide  sufficient  clearance  for

servicing  the  pump,  in-line  heater,  and  control  box.  The  access

panel must be located immediately next to the pump and in-line

heater. Study the roughing-in information.

Electrical Requirements

The installation must have one (1) Class A Ground-Fault Circuit-

Interrupters 

(GFCI's) 

or 

Earth-Leakage 

Circuit-Breakers

(ELCB's). The GFCI/ELCB protects against line-to-ground shock

hazard. 

Use  a  208-240V,  20A,  50/60  Hz 

OR

  Use  a  110V,  20A,

50/60  Hz  dedicated  service  to  wire  the  control  system. 

An

equipment grounding terminal is provided. To reduce the risk of

electrical  shock,  this  terminal  must  be  connected  to  the

grounding  means  provided  in  the  electrical  supply  panel  with  a

conductor  equivalent  in  size  to  the  circuit  conductors  supplying

this equipment. Install this unit in accordance with the Canadian

Electric code, Part I.

Your  physiological  response  to  hot  water  is  subjective  and

depends  on  your  age,  health,  and  medical  history.  If  you  don't

know  your  tolerance  to  hot  water,  or  if  you  get  a  headache,  or

become dizzy or nauseous when using your hot tub, get out and

cool off immediately.

WARNING

1.  Children  should  not  use  spas  or  hot  tubs  without  adult

supervision.

2.  Do  not  use  spas  or  hot  tubs  unless  all  suction  guards  are

installed to prevent body and hair entrapment.

3.  People  using  medications  and/or  having  any  adverse

medical  history  should  consult  a  physician  before  using  a  spa

or hot tub.

4. People with infectious diseases should not use a spa or hot

tub.

WARNING