The Aquatica Digital AD800 Digital Pro housing is issued from the 

world’s most technologically advanced underwater housing lineage, 

it  is  ergonomically  designed  to  place  all  the  essential  camera 

controls under your finger tips and features the following:

A. 

A port locking mechanism to prevent accidental rotation 

 

of the port or extension mounted on the housing

B.  

A Lens Lock Release control that will activate the lens 

 

release button of camera from the outside of the housing.

C.  

A quick release tray, allowing fast and easy removal of 

 

camera with lens and gear attached to the camera body.

D.  

Large ergonomic and easy to operate controls for the 

 

manual and computerized camera functions.

E. 

The industry most flexible strobes connector selection; 

 

options includes standard Nikonos, Classic Ikelite 

 

electrical connections, optical connections for the 

 

Inon and Sea & Sea optical sync cord. An internal 

 

switchboard allows full manual or TTL exposure with 

 

electrical sync cord when a compliant TTL converter is 

 

attached; S-TTL is available when using the proper 

 

strobes

F.  

The Aquatica AD800 Pro Digital is the only housing to 

 

offer exclusive access to all controls and buttons found 

 

on the camera. Special emphasis was made to give the 

 

user easy access to the following controls underwater:

 

- Mechanical shutter release.

 

- Movie Record via a dedicated lever

 

- Shutter speed through the Main-Command Dial

 

- Aperture through the Sub-Command Dial

 

- ISO sensitivity value via a dedicated lever

 

- Fn & Depth of Field buttons via a dedicated toggle lever

 

- Live View mode 

 

- Multi Selector array

 

- Focus / Zoom

 

- AE-L/AF-L & AF-ON access 

 

- LCD panel illumination & information display.

 

- Metering pattern selector

 

- Exposures Compensation

 

- Focus Area Selector 

 

- Delete button access

 

- Live view access

G.  

A comprehensive selection of bayonet mounted ports 

 

including the 4”, 6”, 8” and 9.25 diameter domes, three 

 

flat ports and various extension rings. These are of 

 

manufactured from the finest optical material in order 

 

to preserve the image quality of your Nikon Mount AF 

 

lenses. Adapter rings also allows other brands of ports 

 

to be used with an Aquatica port adapter.

H.  

A large selection of lens gears and related accessories.

PREPARATION OF THE HOUSING

1. Attaching Grip to the housing:

The housing comes with two Grips for both right and left hand 

grips which should be installed on the sides of the housing with 

the  supplied  bolts  and  hexagonal  key  wrench.  It  is  strongly 

recommended to occasionally remove the grips and lubricate the 

screws (see Care and Maintenance: of the housing.)

¼”-20 threaded holes are located on the top of the hand grips 

(# 55) to accept bracket for most popular strobe arm system 

you are using. The Technical Lighting System strobe arm system 

which  has  been  developed  exclusively  for  the  Aquatica  hous

-

ings is highly recommended as it integrates seamlessly with the 

AD800 housing.

Additionally, there are three ¼”-20 threaded holes on the bottom 

of the housing (# 56) that can be used for various mounting ap-

plication including a tripod. And a ¼”-20 threaded hole on the top 

rear half of the housing (# 54) for mounting accessories such as 

a focus assist light or TTL converter bracket.

Mount your strobe arm on the housing and connect the sync cord 

to the housing’s strobe connectors as per your strobe manufac-

turer. If using eletrical sync cord, be sure to read the section re-

garding  the care and maintenance of the O-rings.

2. Lubricating the Main O-ring Seal:

Before use, carefully inspect the Main O-ring seal in the groove on 

the front half of the housing to confirm that it is free from scratches 

or foreign material. Lubricate the O-ring with a light coat of Aquatica 

O-ring lubricant. 

When replacing a Main O-ring, first place this one over the O-ring 

groove and start by pushing the O-ring in the corners. Work your 

way around the O-ring making sure the O-ring is snugly sitting in 

the groove.

For proper handling and maintenance of O-rings please refer to 

the section titled “Care and Maintenance: of the O-rings.”

Page 6

FEATURES

Содержание AD800

Страница 1: ......

Страница 2: ......

Страница 3: ...housing in a sturdy shock proof container and avoid travelling with the camera mounted inside the housing as impact forces especially on the external push buttons will be transferred to the camera Whe...

Страница 4: ...ps removed 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22 23 24 25 26 27 11 8 6 3 4 2 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 48 48 45 49 50 51 52 53 54 55 55 47 28 47 8...

Страница 5: ...utton 42 Protect Picture Control Help Button 43 Menu button 44 Playback button 45 Delete button Format button 46 Release mode dial selector knob 47 ISO button access lever 48 Removable Viewfinder 49 B...

Страница 6: ...with lens attached from the housing 14 FOCUS ZOOM KNOB Turning allows manual focus of a single focus lens or rotation of the zoom mechanism of a lens 15 FOCUS ZOOM PINION GEAR Engages and operates th...

Страница 7: ...removed and replaced with the optional Aqua View 180 Finder 20054 or Aqua View 45 Finder 20059 for a larger displayed image or more comfortable shooting position 49 BKT EXPOSURE BRACKETING BUTTON Pres...

Страница 8: ...These are of manufactured from the finest optical material in order to preserve the image quality of your Nikon Mount AF lenses Adapter rings also allows other brands of ports to be used with an Aquat...

Страница 9: ...ON OF THE LENS There are a number of gear and lens options possible Using the right gear and correctly mounting it on the lens is primordial for a smooth housing operation Follow the installation dire...

Страница 10: ...s hot shoe connector onto the hot shoe base of the camera as seen in drawing at right 2 If using optical connectors make sure your built in flash on the camera is free of obstruction and can go up Con...

Страница 11: ...the housing Align one of the four alignment notches with the opening of the housing 3 Place your hands on opposite sides of the port or extension ring 4 Push with even force on both sides of the port...

Страница 12: ...in connector of your Aquatica housing 2 By using an external iTTL converter connected to the main connector of your Aquatica housing one or two underwater strobes with TTL cords can then be connected...

Страница 13: ...ect focusing it can be tailored to very specific needs and is it worth exploring the multitude of options available 2 The DoF and Fn toggle 5 on the front of the housing gives an exclusive access to t...

Страница 14: ...ce TRANSPORTING THE AQUATICA HOUSING Store the AQUATICA Digital housing in a sturdy shock proof container When travelling by air remove the port This allows for equalization of the air pressure inside...

Страница 15: ...the O ring sits with a cotton swab Be sure to remove any lint the cotton swab may leave behind Inspect the groove for damage 5 Wipe the part of the housing that the O ring seals against with a clean...

Страница 16: ...ns 19353 19350 Close Up Kit Includes holder 5 10 close up lenses TM 19351 Close up lens holder 18508 Neoprene Cover INCLUDED 18429 AF Macro Port Low Profile 18426 AF MF Macro Port INCLUDED 18505 Neopr...

Страница 17: ...17552 Dove tail bracket with 5mm screws For Sea Sea Subal Secam and other popular metric system housings For Aquatica housing Supplied with two 1 4 20 cap screws and 3 16 hexagonal key wrench BALL HE...

Страница 18: ...R REASON IS NOT THE RESPONSABILLITY OF AQUATICA Therefore the appropriate insurance should be maintained by the user Warranty does not apply to replaceable seals or damages to impacts or abrasive surf...