background image

 

 

4 | 

A GH 5   I N S T R UC T I O N   M A N UA L

 

Safety precautions 

Please carefully read and follow the following precautions and recommendations: 

 

Improper transportation, handling or use of this housing might cause a flood or a 
malfunction. Follow all recommendations stated in the next sections of this 
manual. 
 

 

Never remove, change a port or open the housing in a location where sand or 
similar foreign material might come in contact with an O-ring. Be wary of strong 
winds as they could potentially be carrying sand or other harmful particulate 
matter.  
 

 

Always perform a simple preventive seal test without the camera inside after doing 
maintenance on the housing. 
 

 

Non-authorized use of third party accessories, as well as modifications and/or 
alterations not specifically authorized by Aquatica may affect performance, cause 
poor functioning of the controls or impair the sealing integrity of the housing. 
 

 

Always handle the ports carefully. Protect them when not in use to avoid scratching 
the acrylic or glass surface of ports and windows. 
 

 

Always confirm that the ports remain properly attached before rinsing the housing. 
When rinsing without a wired strobe, confirm that the bulkhead strobes connectors 
are sealed with their plug. 
 

 

Never jump into the water with the housing. Have the system handed to you after 
you have made your entry or have it lowered to you on a rope.  
 

 

Never handle the housing by grabbing the port, or if using one, the Aqua View 
finder. 
 

 

Make sure that boat staff are familiar with these procedures and advise them to 
manipulate the housing by using the grips provided with the housing. 

 

Содержание 35000

Страница 1: ...AGH5 INSTRUCTION MANUAL Product 35000...

Страница 2: ...r further information AQUATICA PRODUCT NUMBERS 35000 NK Aquatica housing for Panasonic GH5 Including a single Nikonos connector 35000 OPT Aquatica housing for Panasonic GH5 Including dual optical conn...

Страница 3: ...s 4 Product specifications 5 Package contents 6 Housing schematics 7 Housing preparation 9 Camera preparation and installation 11 Port mounting 14 Port removal 15 Housing closing 16 Housing opening 18...

Страница 4: ...well as modifications and or alterations not specifically authorized by Aquatica may affect performance cause poor functioning of the controls or impair the sealing integrity of the housing Always ha...

Страница 5: ...Focus mode lever Zoom focus wheel Fn2 Fn5 Self aligning controls Housing levers align to the right position regardless of camera levers position for the following controls On off lever Focus mode leve...

Страница 6: ...truction manual Lens chart Spare housing seal O ring CR 2032 coin cell battery for Surveyor Aquatica O ring lubricant container Set of Allen keys Slim flash trigger for 35000 OPT and 35000 OPT VC kits...

Страница 7: ...shown in figure Nikonos or Ikelite page24 4 Accepts Vacuum pump bulkhead page 21 5 Options Aqua View finder 45 or 180 page26 1 Handle ball mounts 4 2 Top 16 mm port2 3 Flash port3 4 Top ball mount 5...

Страница 8: ...1 button 7 Mode dial 8 Mode lock button 9 On Off switch 10 Drive mode dial 11 Zoom Focus dial 12 Fn5 button 13 Playback button 14 Disp button 15 Fn2 Q MENU button 16 Fn3 Autofocus mode button 17 Menu...

Страница 9: ...andle grips the top one or the bottom ones for your tripod Refer to Housing components page 7 STEP 3 Mount your strobes and their arms onto the housing For details about optical flash triggering and w...

Страница 10: ...G For proper handling of O rings follow the detailed instructions outlined in the O rings section page 28 STEP 5 Insert the provided CR 2032 coin cell battery in the Surveyor alarm as described in the...

Страница 11: ...STEP 1 Remove the camera rubber eye cup and the two shoulder strap eyelets NOTE Camera diagrams are taken from the Panasonic GH5 instruction manual STEP 2 Turn off the automatic viewfinder on your cam...

Страница 12: ...g Note The housing dial mechanisms reverse direction of the camera dials If you want to keep using your dials in the direction you are used to on land you can also reverse the dial direction in these...

Страница 13: ...ggering section STEP 7 Slide the saddle and camera inside the housing using the two guiding pins Push it all the way through until you feel the saddle lock engaging Perform a check by pulling on the s...

Страница 14: ...or extension ring inside the housing bayonet Align the bayonet using the four alignment notches in the housing STEP 4 Push with even force on both sides of the port or extension ring until you feel it...

Страница 15: ...STRUCTION MANUAL Port removal STEP 1 While pressing the port release button rotate the port or extension ring counter clockwise until it stops STEP 2 Carefully pull the port or extension ring out of t...

Страница 16: ...u are using a pump Refer to the Surveyor sensor and Vacuum pump sections from page 19 for a complete procedure STEP 3 Make sure that the housing is free of any foreign object that could interfere duri...

Страница 17: ...means you don t have to worry about matching the lever positions on your camera and your housing However note that if the control levers on your housing are not matching those of your camera upon clos...

Страница 18: ...e able to open it directly with the following procedure See note in the Vacuum pump section STEP 1 While pressing the release tab rotate the locking latch counter clockwise NOTE The latch is shown in...

Страница 19: ...ttery under the plastic tab B STEP 2 Push the part of the battery that is sticking out into the holder on A side To remove your CR 2032 battery STEP 1 Push the plastic tab B away from the holder STEP...

Страница 20: ...30 seconds before going back to standby mode Standby mode LED is off System is on standby Water detected Red LED flashing with audible alarm Water is making contact with probe Standby mode LED is off...

Страница 21: ...kit 19233 While it is possible to mount your pump in the front 16mm port it is recommended to use the dedicated port Using the front 16mm port will prevent you from using an external monitor bulkhead...

Страница 22: ...valve plug 1 by sliding the quick disconnect collar 2 STEP 4 Insert the pump stem 5 in the pressure valve and release the quick disconnect collar 2 STEP 5 Make sure the pressure release plug 6 is scr...

Страница 23: ...r serviceable O rings of the housing If unsuccessful in determining the source of the leak refrain from immersing the housing and return it to your authorized service center for inspection NOTE Once y...

Страница 24: ...35000 NK and 35000 NK VC Ikelite style bulkhead 3 5 6 35000 IKE and 35000 IKE VC NOTE Note that none of the offered flash triggering options on the AGH5 housing are TTL compatible For Nikonos 2 and Ik...

Страница 25: ...simply pulling them out of their sockets STEP 7 Unscrew the 6 32 set screws from the optical bulkheads and insert your strobe fiber optic cable inside the bulkheads NOTE Some optical cables come equi...

Страница 26: ...you will have to remove the standard eyepiece To remove your standard eyepiece Note housing shown in this section are not the AGH5 figures are for reference only STEP 1 Using an O ring removal tool re...

Страница 27: ...and free of any physical damage WARNING For proper handling of O rings follow the detailed instructions outlined in the O rings section page 28 STEP 2 Insert your Aqua View finder inside your housing...

Страница 28: ...alvanic corrosion due to electrolysis As time goes and depending on use they will deteriorate and need replacement Contact your dealer to order replacement anodes 19220 O rings When replacing the main...

Страница 29: ...simple seal test without the camera inside should be performed Strapping a weight to the housing and lowering the unit to a depth of 30 to 50 feet of water for at least 10 minutes will assure you that...

Страница 30: ...nsferred to the camera controls and damage them When travelling by air or in situation where atmospheric pressure changes are foreseen leave the housing opened or alternatively remove the port and the...

Страница 31: ...rranty does not apply to replaceable seals or damages to impacts or abrasive surfaces Warranty applies only to products purchased from authorized Aquatica dealers and does not extend beyond the origin...

Отзывы: