Aquatic SERENITY DRIFTBATH Скачать руководство пользователя страница 6

6

 

Aquatic

Serenity DriftBath Owner's Manual & Installation Guide

PRE- INSTALLATION  INSTRUCTIONS

READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

PLEASE NOTE:  THE MANUFACTURER ACCEPTS A 1/4” VARIANCE.  THERE ARE VARIATIONS ON EACH TUB 

AND SPECIFICATIONS ARE SUBJECT TO CHANGE AS WE IMPROVE UPON OUR PRODUCT AS REQUIRED.
THE DIMENSIONS NEEDED FOR SITE PREPARATION AND STRUCTURE BUILDINGS SHOULD BE MEASURED 

FROM THE TUB; AQUATIC ASSUMES NO RESPONSIBILITY FOR PREPARATORY WORK.
Note: A good knowledge of construction techniques, plumbing and electrical installation according to codes are 

required for proper installation.  We recommend that a qualified licensed contractor perform the installation of all 

Aquatic products. Our warranty does not cover improper installation related problems.
WARNING: All units are shipped with loose unions.  Before attempting to test, install, or use your tub, all pump and 

heater unions and “O” rings must be repositioned and tightened.

1.  Immediately upon receiving your Aquatic tub inspect it thoroughly for freight damage. If necessary, contact your 

dealer/distributor immediately (your dealer/distributor must contact Aquatic within 24 hours of receiving unit to file a 

claim.) Should inspection indicate any damage, do not install the bath. Damage or defect to the tub surface claimed 

after the bath is installed is not covered under the warranty.

2.  Remove packing material between tub and pump/heater (most models).

3.  All baths are filled with water and operated in our manufacturing facility prior to shipment. Inspectors ensure watertight 

operation, however rough handling may cause leaks which may be detected prior to installation.

TO INSPECT:

4.  Place the tub in an area where it may be drained after testing.

5.  Fill the tub with hot water (approx. 100

O

 F) to the overflow and allow to stand for a few minutes.

6.  Plug in pump cord and run pump for 10 minutes.

7.  Inspect the tub completely.  Any defect must be reported to Aquatic prior to installation in order to have it covered by 

warranty. Should inspection indicate any damage or leaks, do not install the bath.

Damage or leaks claimed after the bath is installed are not covered under the warranty.

8.  Check to ensure that your installation will conform to all applicable codes and secure necessary permits. All electrical 

and plumbing connections should be made by qualified electricians and plumbers.

DAMAGE OR LEAKS CLAIMED AFTER THE BATH IS INSTALLED ARE NOT COVERED UNDER THE WARRANTY.

WARNING:  FAILURE TO FOLLOW THESE INSTRUCTIONS DURING INSTALLATION WILL RESULT 

IN TERMINATION OF THE WARRANTY:

  

Do not lift the tub by any portion of the plumbing or pump.  

Do not stand in the tub during construction.

DO NOT MAKE ANY ALTERATIONS, ADDITIONS, OR DELETIONS TO THE 

WHIRLPOOL SYSTEM, PUMP OR BATH.

WARNING:  

Pump and piping are factory assembled. Relocation of pump or other modifications could adversely affect the 

performance and safe operation of this tub.  Aquatic shall not be liable under its warranty or otherwise for personal injury 

or damage caused by any such unauthorized modification.

QUIETNESS OF OPERATION:

    

Aquatic has engineered their whirlpool baths from base to lip to ensure quality, value, 

functional design, and maximum bathing comfort. However installation is accountable for as much as 50% of a tub’s operating 

quietness.  Please ensure the following:

•   The floor structure is adequate to support the installation.

•   For quieter operation and heat retention conservation, the walls surrounding the whirlpool may be insulated.

•  Insulate the tub surround. Do not allow any insulation to come within 3 feet of the pump. The area around the pump must 

be clean and free of any foreign matter.

•   Leave 1/8” to 3/16” gap between tub lip and surround.
•   Spread a bed of cement mortar on the floor or subfloor under the whirlpool to reduce vibration and noise.

Содержание SERENITY DRIFTBATH

Страница 1: ...MANUAL INSTALLATION GUIDE Note Read all instructions before proceeding with installation All specifications are 1 4 and are subject to change without notice Dimensions listed in inches mm SERENITY DR...

Страница 2: ...ATION INSTRUCTIONS Structural Preparation 7 8 Plumbing 8 DriftBath with Chromatherapy LED Lights 9 OPERATION INSTRUCTIONS Bath side On Off Controls 10 DRIFTBATH USER INFORMATION 11 FCC CONSUMER INFORM...

Страница 3: ...d reference when contacting the distributor to expedite warranty claims OWNER INFORMATION Model Name Serial Number Purchase Date Distributor AQUATIC Product Registration Information 8101 E Kaiser Blvd...

Страница 4: ...to these instructions during the life of your DriftBath Failure to comply with these instructions may invalidate your warranty If you have any questions concerning installation operation maintenance o...

Страница 5: ...may lead to unconsciousness with the possibility of drowning Never use the bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics na...

Страница 6: ...tand for a few minutes 6 Plug in pump cord and run pump for 10 minutes 7 Inspect the tub completely Any defect must be reported to Aquatic prior to installation in order to have it covered by warranty...

Страница 7: ...roduct WARNING Factory skirts do not allow for blocking up of the tub base All blocking must be solid and provide uniform support to the tub base 3 Tub must rest entirely on the base DO NOT SUPPORT TH...

Страница 8: ...other finishing materials Apply a second bead of silicone between the first course of tile and the bath deck PLUMBING 1 After securing tub in place normal waste and overflow water spout and valves ar...

Страница 9: ...tlet as in the above figure to a minimum 20 amp 120 vac dedicated circuit breaker which is GFCI protected not supplied INSTALLATION INSTRUCTIONS DRIFTBATH WITH CHROMATHERAPY LED LIGHTS TEST RESET Ligh...

Страница 10: ...May Induce Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6o F The symptoms of hyperthermia include...

Страница 11: ...de reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...

Страница 12: ...MS CLEAN PLUS does not replace the necessity to purge your DriftBath system at least twice a month with a low foaming detergent and bleach SURFACE CLEANING Use common household non abrasive cleaners f...

Страница 13: ...ies of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture d...

Страница 14: ...oluble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water suppl...

Страница 15: ...r trips 1 Low voltage 2 Motor windings connected for wrong voltage 3 Inadequate ventilation 4 Wiring too small 1 Contact your electrician 2 Contact Aquatic 3 Refer to installer dealer 4 Contact your e...

Страница 16: ......

Страница 17: ...1 The tub is subject to damage during shipping by carriers faulty installation maintenance abuse accident or other damages 2 The tub is installed outdoors 3 The tub is not installed in accordance wit...

Страница 18: ......

Страница 19: ......

Страница 20: ...AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANDBTH F O D 9009 02 13...

Отзывы: