background image

A.  Introduction

  ..........................................................................................................................

2

 

1. Unit

 Description

  .....................................................................................................

3

 

2. How

 A

 Heat

 Pump

 W

orks ......................................................................................

3

 

3. LED

 Display

 &

 Status

 Light

 Descriptions

  ........................................................

4-5

B.  Operational Instructions.....................................................................................

Pages 6 - 7

 

1. W

ater Flow

 

2. W

ater Pump

 Timer

 Setting

 

3. Thermostat

 Setting

 &

 Mode

 Selection

 

4. Optional

 Time

 Clock

 Override

 Switch

 

5. T

ime Delay

 Modes

 

6. Normal

 Operation

 Indicators

 

7. Pool/Spa

 Cover

 Use

 

8. Spa

 Heating

 

 

9. Defrost

  Control

 In

 Cold

 W

eather

C.   Heat Pump Maintenance & Precautions

........................................................Pages 8 - 12

 

 

1. Air

 Flow

 &

 Service

 Access

 Clearances

 

 

2. Freeze

 Condition

 Precautions

 

 

3. Owner

 Cleaning

 &

 Maintenance

 

 

4. Professional

 Maintenance

 

 

D. Operational Sequence & 

Troubleshooting Flow Chart

 ..................................................

10

E. 

Warranty Service 

 ..............................................................................................................

11

 

Table of Contents

A. Introduction

Congratulations on

 the

 purchase

 of

 your

 new

 swimming

 pool/spa

 heat

 pump.

  Utilizing

 heat

 

pump technology 

is the 

most efficent 

method of 

heating a 

swimming pool. 

 Please 

take a 

few 

minutes to

 read

 this

 owner

’s 

manual to

 familiarize

 yourself

 with

 the

 operation

 and

 features

 of

 

the heat

 pump.

Please be 

sure to 

fill out 

the warranty 

card and 

send it 

back to 

us.  If 

you have 

any questions 

regarding your

 heat

 pump,

 or

 if

 you

 have

 a 

need for

 service,

 please

 contact

 us

 at

 our

 toll-free

 

number listed

 on

 the

 back

 page.

Important Information to Record

Installer Name ________________________________________________________________

Installer Phone ____________________________

 Install Date __________________________

Model Number _________________

Serial Number __________________________________

Page 11

E. Warranty Service

Before calling for warranty service you should check the following:

1.  Clean 

all filters 

and traps 

in the 

pool circulation 

system. Low 

water flow 

will cause 

the unit 

to shut

 down

 or

 cycle.

2.  C

hec

k a

nd 

adj

ust

 al

l w

ate

r fl

ow

 va

lve

s a

nd 

adj

ust

 to

 th

e p

rop

er p

osi

tio

ns 

to 

ins

ure

 pr

ope

r w

ate

flow through the heater.

3.  

Check the

 water

 pump

 timer

 setting

 to

 insure

 there

 is

 enough

 time

 all

otted for

 a 

proper heating

 

cycle.

4.  Check 

all circuit 

breakers and 

disconnects.  Note: 

More than 

one disconnect 

may be 

required 

to shut

 of

f or

 turn

 on

 power

 to

 the

 heater

.

5.  C

onfi

rm

 th

at 

all 

hea

ter

 c

ont

rol

s, 

the

rm

ost

at, 

the

rm

ost

at 

sel

ect

or 

sw

itc

h, 

res

et 

tri

ppe

r, 

and 

optional auto heat switch (if so equipped), are in the correct position.

6.  

If a

ny 

3rd

 pa

rty

 co

ntr

ol d

evi

ces

 ar

e in

sta

lle

d o

n th

e p

ool

/sp

a sy

ste

m m

ake

 su

re 

the

y a

re 

fun

ctio

n-

ing properly

.  Factory

 service

 technicians

 will

 not

 diagnose

 3rd

 party

 external

 control

 devices.

   

All external

 controls

 are

 disconnected

 during

 warranty

 service

 and

 the

 heater

 is

 diagnosed

 as

 

manufactured then

 reconnected.

7.  The

 limited

 factory

 warranty

 does

 not

 cover

 damage

 or

 conditions

 caused

 by

 but

 not

 limited

 

to the

 following:

Improper installation.

Improper use.

Inadequate run time on the water pump timer.

Improper water flow to the heater.

Conditions caused

 or

 associated

 with

 3rd

 party

 external

 controls.

Sprinkler damage.

Roof run

 of

f damage.

Freeze damage

 or

 operation

 damage

 during

 freezing

 conditions.

Salt and/or

 sand

 or

 debris

 damage.

Lack of

 maintenance

 and/or

 cleaning.

Unauthorized servicing

 of

 the

 heater

 during

 the

 warranty

 period.

Normal rusting

 and

 oxidation

 of

 metal

 components.

Non warranty

 service

 calls

 such

 as

 inspections,

 maintenance,

 or

 problem

s unrelated

 to

 the

 

heater as

 it 

was manufactured

 are

 not

 covered

 under

 the

 warranty

.

8.  Y

ou can 

contact the 

factory @ 

888-297-3826 to 

be pre-qualified 

and scheduled 

with a 

factory 

authorized service

 center

 in

 your

 area.

 Have

 your

 model

 number

, serial

 number

 and

 installa

-

tion date

 ready

.

IMPO

rTA

nT

 nOTES

:

The heater

 will

 not

 heat

 faster

 if

 you

 turn

 the

 thermostat

 all

 the

 way

 up.

 The

 heater

 will

 never

 run

 

without water 

running through 

it from 

the pool/spa 

filter pump. 

 When 

the heater 

is started 

the 

fan will

 run

 right

 away

.  The

 compressor

 will

 start

 after

 a 

5 to

 7 

minute delay

. The

 heating

 light

 

will come

 on

 only

 when

 the

 compressor

 is

 running.

  The

 heater

 will

 produce

 condensation

 at

 a 

steady rate.

 The

 condensation

 exits

 the

 heater

 from

 the

 bottom

 drains.

  The

 more

 humidity

 the

 

more condensation.

 The

 thermostat

 is

 accurate

 within

 three

 degrees

 and

 may

 not

 always

 match

 

exactly to

 the

 degree

 numbers

 printed

 on

 the

 control

 panel

 as

 it

 is

 ef

fected by

 the

 humidity

 and

 

other factors.

  The

 heater

 is

 designed

 to

 shut

 of

f in

 defrost

 mode

 when

 the

 air

 temperature

 drop

 

below 45˚F to 50˚F.

NOTICE

Technicians See Separate “Installation Manual”.  

Specifications may change without notice.

  