Electrical Supplies:  Relay, associated connectors, wire, electrical tape and mounting hardware may
be needed. For plumbing the pump to rigid (polybutylene or PEX) tubing, a flexible connector hose
is strongly recommended for the pressure side. If the Aquajet pump is mounted at a different loca-
tion than the old pump, flexible connector hoses will be required on both the inlet and outlet side.  A
screen-filter should always be used between the RV water tank and the pump. 

Planning the installation ("AQUAJET RV SERIES" ONLY):

1.  Determine whether or not your RV is currently using an 'Intellitec' pump controller (i.e. three or

more "momentary" type switches which can be used to turn the pump on/off.).  There are at least
four (4) different types of Intellitec controllers currently in use, but not all of them can be used
with the Aquajet RV.   

Specifically, only a four terminal, 10 or 15 Amp rated Intellitec con-

troller can be used to directly control the Aquajet RV.  Intellitec 7 Amp, 3 Amp or non-rated
controllers should NEVER be used to switch the load of the Aquajet RV. 

The Intellitec controllers are typically located in the pump compartment (on some Fleetwood vehi-
cles, however, they are located near the circuit breaker panel under the refrigerator). Once
you've located the controller, before taking anything apart, make a sketch of the existing wiring
including the colors of the wires and how they are attached.  If you do have an Intellitec controller
that does not say either "10 Amp" or "15 Amp" on the label, then you must either:

a) Replace it with a 10 or 15 Amp rated controller.  For your convenience,

Intellitec's phone number is (708) 268-0010.

b) Procure a 30 Amp rated relay (through either a local automotive store or directly through

the Aquatec catalog, product number 20-267) to augment your existing controller.  Please
refer to schematics figures 3, 4 and 8.   

2.  Determine whether or not your present wiring is capable of supplying 10 Amps without generating

an excessive voltage drop.  For a 10 Amp load, 14 AWG can typically be used up to 10 ft dis-
tances, 12 AWG up to 20 ft distances, and 10 AWG for distances of more than 20 ft.  You can
also determine if your wiring is adequate by using a Voltmeter, as follows: 

a) Probe inside the wirenuts that connects the existing pump.
b) Write down voltage at pump with all valves closed and pump inactive.  This is your nomi-

nal battery voltage.

c) Open a faucet or faucets so you get the pump running continuously.
d) Measure the voltage again at the pump wirenuts.
e) Note the running voltage.
f) Subtract the running voltage from the nominal voltage. This is your "voltage drop". 

If the voltage drop with your existing pump (typically 5 Amps) exceeds 1 Volt you will need to pull
a new heavier (10-12AWG) 'hot' wire to the pump AND use a 30 amp relay (referenced in section
1b above) to connect your Aquajet RV (see figures 1 and 2).  

Содержание Aquajet ES Series

Страница 1: ...electrical fire When installing either an Aquajet RV or ES Series pump positive voltage 12VDC must be con nected to the Aquajet s red fused leadwire Reversing polarity will instantly blow the fuse an...

Страница 2: ...holding tank and the pump to prevent debris from entering the pump Particulate matter may cause the valves inside the pump to stick open This filter needs to be cleaned on a regular basis or it will r...

Страница 3: ...he existing wiring including the colors of the wires and how they are attached If you do have an Intellitec controller that does not say either 10 Amp or 15 Amp on the label then you must either a Rep...

Страница 4: ...ey the existing plumbing and identify the suction line i e the line going from the water hold ing tank to the pump If there is not a screen filter currently on this line then one should be pro cured f...

Страница 5: ...ide for additional infor mation b Check your RV Owner s Manual for the recommended fuse rating for the pump branch cir cuit If your recommended rating is rated 10 Amps or more you can proceed directly...

Страница 6: ...ard Polybutylene or PEX tubing If your RV is currently plumbed with soft walled reinforced hose see Diagram 5 then your system should be perfectly sufficient as is By installing a piece of IAPMO appro...

Страница 7: ...d end of Qest threaded adapter into outlet port marked with arrow pointing away from pump of the Aquajet pump Lock fitting in place by pushing down retainer slide 7b For old pump outlets directly conn...

Страница 8: ...ttery 19 Have an assistant briefly power up the pump using one of the RV s standard pump switches 20 Water should be flowing into bucket see Figures 6 and 7 or into the sinks see Figure 5 21 Allow Aqu...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...ermore this warranty does not cover any damage or defects occurring from customer s fail ure to follow pump label instructions or Operational and Installation Guidelines The warranty guarantees that p...

Отзывы: