background image

A Q U A T E C E Q U I P M E N T . C O M

AP300SP / AP960SP / AP1360SP 

SOLAR PANEL & SUBMERSIBLE PUMP KIT

TROUBLESHOOTING

Problem

Reason

Solution

Water Pump Not 

Working

No Power

Check that the plug is connected 

and turned on

Impellor is blocked with 

sludge or limescale

Clean the Impellor as per 

the instructions

Running without sufficient water

Submerse the equipment underwater 

then plug in. Refill if necessary.

Blocked Impellor chamber or ceramic 

shaft is broken

Clean the Impellor. Check for ware. 

Replace if necessary.

Water Pump is noisy

Blockage in pump

Clear the blockage

Impellor & Shaft worn out

Replace Impellor & Shaft

Impellor broken

Replace Impellor

Flow adjuster set to minimum

Open the flow adjuster and allow 

water to flow

Unit inlet is blocked or the water 

pump outlet is blocked

Clear all blockages

The height to which you are pumping 

is too high for the given model of 

pump.

Select a bigger model of pump

AP300_960_1360 Instructions.indd   9

31/5/18   12:25 pm

Содержание AQUAPRO 02AS510

Страница 1: ...SOLAR PANEL SUBMERSIBLE PUMP KIT INSTRUCTION MANUAL HOTLINE 1300 AQUATEC DATE OCT 2018 v2 0 MODEL 02AS510 02AS512 02AS514 AP300_960_1360 Instructions indd 1 31 5 18 12 25 pm...

Страница 2: ...ectly off energy from the sun via the solar panel Eco Friendly Exceptional low dB noise rating with low mechanical vibration Tool less Assembly for Easy maintenance No special tools required Easy to i...

Страница 3: ...on the tank or water body Always unplug the pump from the Solar Panel when not in use Never pull the cable to disconnect the plug Grasp the plug and pull to disconnect Be sure the Pump is submerged co...

Страница 4: ...SPECIFIC SAFEGUARDS Do not operate the pump without water at any time permanent damage may occur Be sure the equipment is submerged completely in the water Do not use this pump in a dry mounted appli...

Страница 5: ...ize hot water to soften the tube and expand the diameter to fit over the riser end Remember to use Stainless Steel hose clamps to fasten the hose on to the Hosetail This is to ensure that the pipe doe...

Страница 6: ...housing apart from the pump 3 Turn the impeller cover together with flow valve clockwise to the end and then carefully pull the impeller cover together with flow valve apart from the pump 4 Lift out...

Страница 7: ...other accessories or attachments might present a risk of injury to persons Only use the accessory or attachment for its stated purpose 1 2 3 4 5 Filter Housing Flow Adjuster Removable Impellor Cover...

Страница 8: ...ellor Cover 4 Impellor and Shaft Assembly 12AS064 12AS065 5 Motor Body only Available on Request 6 DC Solar Pump Only not all parts included with this model 12AS073 12AS074 7 Solar Panel Only 12AS067...

Страница 9: ...in Refill if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for ware Replace if necessary Water Pump is noisy Blockage in pump Clear the blockage Impellor Shaf...

Страница 10: ...exhaustible Exhaustible Items and are not covered under the Warranty The Warranty will be void if any of the following events occur as determined by us at our sole discretion Voiding Events any tamper...

Страница 11: ...A Q U AT E C E Q U I P M E N T C O M AP300SP AP960SP AP1360SP SOLAR PANEL SUBMERSIBLE PUMP KIT NOTES AP300_960_1360 Instructions indd 11 31 5 18 12 25 pm...

Страница 12: ...HOTLINE 1300 AQUATEC AP300_960_1360 Instructions indd 12 31 5 18 12 25 pm...

Отзывы: