AQUASYSTEM KFC Series Скачать руководство пользователя страница 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Request technical service whenever required. 

When the device stops operating or operates in a strange manner, 
immediately  turn  it  off  and  contact  technical  service.  Do  not  use 
broken equipment, as it may result in accidents. 

 

Do not cause shock to device

s main body. 

It may result in pump

s malfunction, breakdowns and leakage. 

 

Do not transfer liquids contaminated with sludge.   
Transferring  liquids  contaminated  with  sludge  may  damage  the 
propeller,  shaft  and  bearing,  resulting  in  general  performance 
decrease. 

 

Permitted pressure.   
Permitted pressure

s range: 0.3

0.7Mpa 

 

Do not pull water or chemicals on the motor.   
It may result in electric shock and fire. 

 

Transfer liquids  of  viscosity  no  higher  than  100  cP  (pump

s  uplift 

capability decreases by higher viscosities). 

 

Do not bend the joint part between the ball valve and the hose. 

 

Replace the hose if you have found the following: 
partial extension

bending

leakage

bulges

nipple connection           

loosening 

Please remember, that the safety measures and warnings pointed 

out  in  this  manual  are  not  exhaustive  for  all  possible  situations. 
Although  we  have  designed  our  product  to  be  as  safe  as  possible, 
persons operating and maintaining the device should strictly follow 
all safety rules in the operation/maintenance area. 

Содержание KFC Series

Страница 1: ...acids alkalis and solvents INSTRUCTION MANUAL Air driven KFC Series Contents 1 Safety precautions 2 3 4 Before using the device 5 Inspection usage spec 6 Parts description 7 KFC103A N Drawings 8 KFC104A N Drawings 9 Warranty and service ...

Страница 2: ...manual misusing the device may result in accidents Keep the manual in a safe place and refer to it when necessary 1 Not following the instructions may result in death or serious injuries Not following the instructions may result in death or serious injuries Not following the instructions may result in human injuries and material damage ...

Страница 3: ...invalidates the warranty Refer to the permitted liquids list This pump has been designed for acids alkalis and solvents transfer however there are acids alkalis and solvents which should not be transferred Transferring liquids other than pointed out by AQUASYSTEM may result in accidents for which the pump maker is not responsible It is also the user s responsibility to properly and safely use dang...

Страница 4: ...ot doing so may result in dangerous chemical reactions Pay attention to hardening of the hose Transferring some of the liquids may cause hose s hardening with time This may eventually lead to leakage and falling out of the hose In such cases the hose has to be replaced before using the device Do not run the device in a dry state Also do not go away from the device when operational Liquid s tempera...

Страница 5: ...rmitted pressure s range 0 3 0 7Mpa Do not pull water or chemicals on the motor It may result in electric shock and fire Transfer liquids of viscosity no higher than 100 cP pump s uplift capability decreases by higher viscosities Do not bend the joint part between the ball valve and the hose Replace the hose if you have found the following partial extension bending leakage bulges nipple connection...

Страница 6: ...r making sure the air supply valve is closed connect the air hose 3 Close the valve and open the air supply valve Then open the valve gradually to adjust the delivery rate 4 After use close the air supply valve and unplug the air supply hose After that open the valve Valve location is marked on the next page TECHNICAL SPECIFICATIONS Model KFC103A N KFC104A N Max delivery rate 65L min Max uplift cl...

Страница 7: ...A N 1 Motor s main body Motor s main body 2 Air coupler Air coupler 3 Drum Can Adapter Plastic G2 Drum Can Adapter Plastic G2 4 Valve Plastic 3 4 Valve SUS 3 4 5 Reinforced PVC Hose 2m φ25 SUS304 Hose 2m φ25 6 PP Nozzle SUS304 Nozzle 6 ...

Страница 8: ...7 KFC103A N DRAWINGS 7 ...

Страница 9: ...KFC104A N DRAWINGS 8 ...

Страница 10: ...e the service will not be free In both cases covering shipment related costs is customer s responsibility Product s breakdown has been reported within 1 year from the date of purchase but The product has been misused The product has been repaired serviced however not by AQUASYSTEM The product has not been stored or maintained properly There are no documents receipts which would prove the purchase ...

Отзывы: