background image

aquascapeinc.com

I N S T R U C T I O N S   &   M A I N T E N A N C E

AQUAFORCE

®

SOLIDS-HANDLING

POND PUMP

AquaForce

®

 1000 

Solids-Handling 

Pond Pump

Item #91011

AquaForce

®

 1800 

Solids-Handling 

Pond Pump

Item #91112

AquaForce

®

 2700 

Solids-Handling 

Pond Pump

Item #91012

AquaForce

®

 3600 

Solids-Handling 

Pond Pump

Item #91113

AquaForce

®

 5200 

Solids-Handling 

Pond Pump

Item #91013

Содержание 91011

Страница 1: ...HANDLING POND PUMP AquaForce 1000 Solids Handling Pond Pump Item 91011 AquaForce 1800 Solids Handling Pond Pump Item 91112 AquaForce 2700 Solids Handling Pond Pump Item 91012 AquaForce 3600 Solids Ha...

Страница 2: ...ase of maintenance makes this pump the ideal choice for discriminating pond owners The AquaForce protective pre filter cage allows the pump to be placed directly into the pond AquaForce pumps are able...

Страница 3: ...all a properly grounded receptacle outlet acceptable for outdoor use and protected from snow and rain B Inspect cord before using C Do not use extension cords D Any wiring of pumps should be performed...

Страница 4: ...ected This pump has been evaluated for use with water only Input amps wattage see chart below Model Number 1000 1800 2700 3600 5200 Maximum Flow Rate GPH 1 070 2 149 2 695 3 868 5 284 Maximum Head Hei...

Страница 5: ...by a ground fault interrupter Ex 10 Once the pump is running and water is circulating check for any leaks where the external connections are made Using the AquaForce as a Winter Bubbler The AquaForce...

Страница 6: ...s stuck to the filter cage Ex 14 Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow rates then you will need to remove the pump from the lower...

Страница 7: ...receiving the correct voltage Pump not working The ground fault circuit interrupter GFCI may have tripped The pump is not receiving the correct voltage Troubleshooting Ex 20 Removing scale build up wi...

Страница 8: ...and winterized otherwise warranty is null and void No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is ass...

Страница 9: ...N AquaForceMD 1000 Solids Handling Pond Pump R f rence 91011 AquaForceMD 1800 Solids Handling Pond Pump R f rence 91112 AquaForceMD 2700 Solids Handling Pond Pump R f rence 91012 AquaForceMD 3600 Sol...

Страница 10: ...aquascape4 pinterest com aquascapeinc instagram com aquascape_inc Rejoignez nous sur Les pompes pour filtration et cascades AquaForce asynchrones et r sistantes au colmatage effectuent ce que la plupa...

Страница 11: ...de la s curit de l utilisateur E D branchez la pompe de la prise de courant lorsque vous ne vous en servez pas ou avant de la sortir du plan d eau F Pour r duire le risque de d charge lectrique tout...

Страница 12: ...la pompe de bassin de traitement des solides AquaForceMD Tension d entr e 120 V c a Fr quence d entr e 60 Hz Pompe submersible Pour utilisation ext rieure ou int rieure Protection thermique Pompe valu...

Страница 13: ...ascades ou un filtre pressuris Ex 9 Branchez la pompe un disjoncteur de fuite la terre Ex 10 Lorsque la pompe fonctionne et que l eau circule par le s filtre s ou les cascades v rifiez toute possibili...

Страница 14: ...ant les d bris de la cage de filtration Retirez les d bris log s dans la cage de filtration de la pompe et ou utilisez un tuyau d arrosage pour nettoyer les d bris coll s sur la cage de filtration Ex...

Страница 15: ...ension D pannage Si l assemblage de la turbine du rotor et la partie interne de la pompe contiennent des d p ts calcaires excessifs nettoyez avec un acide doux comme du vinaigre blanc ou du CLR et une...

Страница 16: ...a garantie exclut les co ts de main d uvre de retrait du produit d exp dition et les d penses li es l installation et la r installation du produit Tous les produits qui incluent la plomberie tubes pom...

Отзывы: