DX-300 – DIVER HELD MAGNETOMETER

 User Manual 

 

carry out straight line searches to a set distance in a variety of directions.  If you 
detect even the smallest change in audio in any given direction, note the point of 
the peak response.  
 

6.

 

Carry out a search through the initial peak response on a line that intersects at 90 
degrees, a further peak response should occur somewhere on the intersect line to 
confirm the true position of the target. 

 

7.

 

If  you  are  just  doing  a  general  search  of  an  area,  you  will  probably  want  to 
establish some sort of grid and move in straight lines a good starting point is to 
search at a separation of 2 or 3 metres (6 to 10 feet), Note. The midpoint between 
successive  lanes  is  only  half  the  separation  distance,  hence  the  DX-300  is  not 
required to detect laterally at the full lane separation distance. 
 

Note:  Different  environmental  conditions  may  make  a  small  difference  to  the 
threshold setting as you perform your search, which can be readjusted by the SET 
AUDIO control knob. 

 

Care and Maintenance 

 
Proper care of your 

Aquascan DX-300

 will be repaid by a long and trouble free life 

and attention should be given to the following points: - 
 

1.  After use, and before removing plugs, make sure that the unit is switched off, 
and wash down with clean fresh water.  

NEVER

 use chemicals to clean your DX-

300 as these will damage o-rings and seals, which can cause them to fail and allow 
the incursion of water into the control unit. 
 
2.  Remove  the  Sensor  Probe  and  Bonephone/Headphones  plugs  from  the 
bulkhead sockets, and make sure the Rubber Seal is free from sand or other debris 
(remove and clean if necessary).  Dry off the plug pins and blow any moisture out 
of the sockets.  You can use a Q-Tip to clean and dry the sockets.  Ikelite does not 
recommend  using  silicone  grease  or  any  other  material  on  the  connectors.    The 
rubber seal provides adequate isolation of the connectors from the water.  Use of 
these type products tends to accumulate sand and other debris which can actually 
interfere with the seal.  Never utilize petroleum  products such as Vaseline, since 
these will harden the rubber seal making it non-functional.  The rubber seal should 
be replaced any time it becomes stiff, as this will interfere with its function. 

 

Note:    A  dirty  or  corroded  connection  is  the  most  common  cause  of  poor 
performance  of  underwater  detection  equipment.  Keep  your  connectors  clean 
and dry between uses. Use water dispersants as required. 

 

1.

 

Dry the DX-300, paying particular attention to the area around the plugs. 

 
2.

 

Clear any excess water  present on the bulkhead  by blowing or wiping with a 
soft cloth. 

 

Содержание DX-300

Страница 1: ...Aquascan Int Ltd all rights reserved This document must not be replicated in whole or part without the prior express permission of Aquascan International Ltd Issue date 24th June 2014 AQUASCAN INTERNATIONAL LTD AQUASCAN HOUSE HILL STREET NEWPORT SOUTH WALES UK NP20 1LZ Tel 44 1633 841117 Fax 44 1633 254829 Email info aquascan co uk Website www aquascan co uk ...

Страница 2: ... Charging the batteries 8 Underwater Operation 9 Care and Maintenance 10 Battery Care Checking Battery Performance Status 12 Troubleshooting Guide No Response from the DX 300 Module Erratic Performance from the DX 300 Module 14 DX 300 Specifications 15 DX 300 Accessories 17 DX 300 Optional Accessories 18 DX 300 Professional Kit 19 Manufacturer Contact Information 20 EC Declaration of Conformity Pr...

Страница 3: ...f the pipe or cable E O D Security There are unlimited applications in all types of underwater investigation for the presence of ordinance weapons etc Salvage The DX 300 is a useful tool for the successful recovery of lost items either in low visibility or where lost in soft sediment It is the ideal tool to complement surface operated searching The tool most requested by users of boat towed magnet...

Страница 4: ...ial areas or under transformers and high tension power lines will generally give the user problems with false readings In the water it is just important to be clear of any influence that may be generated by a large steel vessel and of course equipment on the diver such as a steel dive cylinder If you are searching for small items of debris such as a cannonball a pistol a hand tool you will probabl...

Страница 5: ...ity of the DX 300 and how to use the controls It is much easier to learn to operate the unit without the challenges of limited visibility restrictive dive equipment currents etc So please take the time to perform this Initial Testing of your unit before venturing into the water with it 1 Charging the batteries The DX 300 is supplied only partially charged and will require a full 14 hours charging ...

Страница 6: ...has elapsed if the unit just requires a top up charge NB The operational usage time on a full charge with a healthy battery pack will be in the order of 24 hours recharging will require a 1 hour charge time for each 2 hours of usage in other words a 2 1 usage charge time to replenish Some earlier types of charger had a 6 hour time out period requiring the charger to be switched off and back on to ...

Страница 7: ...s so just start turning one way until you either reach the audio threshold or the stop point of the control If you reach the stop point without finding the audio threshold start turning the other way until you do Once you have found the audio threshold the first time you test the unit the SET AUDIO control should be in the near vicinity of the correct location for future uses so you will normally ...

Страница 8: ...d in a number of ways the choice will be influenced by the conditions and diver preference The most obvious choice is worn clipped to any suitable location on the diver with the D Ring mounting system provided with the unit Other options include the quick release belt harness strapping it to the upper arm or mounting it to the DX 300 Armsaver optional accessory supplied with the Professional syste...

Страница 9: ...lugs make sure that the unit is switched off and wash down with clean fresh water NEVER use chemicals to clean your DX 300 as these will damage o rings and seals which can cause them to fail and allow the incursion of water into the control unit 2 Remove the Sensor Probe and Bonephone Headphones plugs from the bulkhead sockets and make sure the Rubber Seal is free from sand or other debris remove ...

Страница 10: ...formance it is important to charge your DX 300 periodically when not in use Checking Battery Pack Performance Note For routine maintenance this should be carried out every three months The recommended procedure is as follows 1 0 Connect the Sensor Probe to your DX 300 module 1 1 Power on your DX 300 and leave it on overnight to fully discharge the battery 1 2 Power off the DX 300 and disconnect th...

Страница 11: ...age will result in total lack of functionality 2 Check that both Sensor Probe and Bonephone are correctly connected 3 Try using an alternative Bonephone AQ1B Headphones 4 Try using an alternative Sensor Probe if available 5 Check that both the Sensor Probe and Bonephone are in good condition Check by substitution if possible or by monitoring the nominal resistance of Bonephone Headphones Connectin...

Страница 12: ...ne are clean If necessary reduce the contact resistance by slightly prising the gap in the male contacts this will increase the firmness of the connector on insertion 4 Check for visible damage to Sensor Probe cable and connector which could have caused water ingress 5 Check that the male connector seals are in place and clean 6 If you are unable to determine the cause of the erratic behaviour con...

Страница 13: ...mm Probe Length 750mm CABLE Construction Twin core shield Diameter 6 7mm Sheath Polyurethane Length 2m approx 6ft POWER Power Internal Rechargeable 2200 NiMH battery Charger Universal 100 250v AC Charge time from empty 14Hrs CONTROLS Power On Off Incorporated with Sensitivity Sensitivity Switch Off Low Med High Extra High Set Audio Multi turn Pot WEIGHTS Control Unit 1Kg Probe Cable 0 72Kg Basic o...

Страница 14: ...Headphones feature an adjustable volume control and a comfortable fit for the user AQ 4 062 DX 300 Bonephone with extending flex cable This version is in all other respects the same as the AQ 4 061 The option of a flexible cable that will extend and retract is preferred by some divers particularly in low visibility conditions to minimise the risk of the cable fouling any obstructions AQ 4 031 DX 3...

Страница 15: ...h 100v to 250v AC 50 60HZ input voltage range this unit is used to recharge the internal battery pack of the DX 300 Control Module The charger can be supplied with option of US UK or European type Power Connector in the form of a push fit shoe or as a conventional power lead DX 300 Control unit ...

Страница 16: ...TOMETER User Manual 16 DX 300 OPTIONAL ACCESSORIES Optional DX 300 Armsaver probe extended Optional DX 300 Armsaver probe retracted DX 300 Control Unit mounted in optional Armsaver Close up of DX 300 Armsaver Probe connection ...

Страница 17: ... Manual 17 DX 300 Professional Kit Includes Transit Storage case for DX 300 Control Unit Sensor Probe D Ring Waist Belt Charger Bonephone Underwater Headphones and Armsaver kit DX 300 PROFESSIONAL KIT DX 300 Professional Kit Case closed ...

Страница 18: ...equipment or to arrange a repair please use the following contact information Mailing Address Aquascan International Limited Aquascan House Hill Street Newport South Wales NP20 1LZ United Kingdom Tel 44 0 1633 841117 Fax 44 0 1633 254829 E mail Sales Enquiries sales aquascan co uk General Inquiries info aquascan co uk Technical Support support aquascan co uk Website www aquascan co uk ...

Страница 19: ...claration will lose its authority Equipment description Diver Held Magnetometer Model DX 300 Manufacturer Aquascan International Ltd Aquascan House Hill Street Newport NP20 1LZ S Wales Tel 44 0 1633 841117 Fax 44 0 1633 254829 Email info aquascan co uk Applicable directives EN 55011 General Emission Standard Class A Group 1 EN 50082 Generic Immunity Standard Part 2 A technical construction file fo...

Отзывы: