Performance Data Sheet for the EQ-1000 Aquasana Whole House Rhino
®
Water Filter System
Models
Replacement
Max Operating pressure Rated capacity
Operating temp. range Rated flow
EQ-1000
EQ-1000R
100 psi
1,000,000 gallons
40-90º F
7.0 gpm
Manufactured by: Aquasana, Inc. 6310 Midway Road · Haltom City, Texas 76117 · 866-662-6885
For use with municipally treated water only. Do not use with water that is microbiologically unsafe or of
unknown water quality without adequate disinfection before or after the system.
This system has been independently tested according to NSF/ANSI 42 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42.
Independent testing was performed under standard laboratory conditions, actual performance may vary. All data reported is
associated with quality control that met method, EPA, NSF/ANSI or internal laboratory specification.
NSF/ANSI 42
Influent Challenge
Chlorine
Pressure drop
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available
2.02 mg/L ±10%
10.5 psi
≥50%
>97.4 %
Pass
Data Summary Table
Sample
Point
Accumulated
Volume (gal)
Dynamic Pressure
(psi)
Chlorine, Free Available (mg/L)
% Reduction of
this sample
Influent
Effluent 1
Startup
10
60
2.04
ND (<0.01)
99.51%
6%
60,000
60
2.09
ND (<0.01)
99.52%
12%
120,000
60
2.09
ND (<0.01)
99.52%
18%
180,000
60
2.07
ND (<0.01)
99.52%
24%
240,000
60
1.93
ND (<0.01)
99.52%
30%
300,000
60
1.91
ND (<0.01)
99.52%
36%
360,000
60
2.02
ND (<0.01)
99.48%
42%
420,000
60
1.82
ND (<0.01)
99.45%
48%
480,000
60
1.89
ND (<0.01)
99.47%
50%
500,000
60
2.00
ND (0.02)
99.00%
54%
540,000
60
1.95
0.09
97.73%
60%
600,000
60
2.07
0.05
97.58%
66%
660,000
60
1.84
0.08
95.65%
72%
720,000
60
1.84
0.08
99.54%
78%
780,000
60
1.93
0.06
96.89%
84%
840,000
60
2.19
ND (<0.02)
98.62%
90%
900,000
60
2.08
0.06
97.12%
96%
960,000
60
2.11
0.15
91.94%
100%
1,000,000
60
2.09
0.15
92.82%
Filter is only to be used with cold water.
Filter usage must comply with all state and local laws.
Testing was performed under standard laboratory
conditions, actual performance may vary.
• All contaminants reduced by this filter are listed.
• Not all contaminants listed may be present in your water.
• Does not remove all contaminants that may be present in tap water.
Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.
See owner’s manual for general installation
conditions and needs plus manufacturer’s
limited warranty.