Do not use with water that is microbiologically
unsafe or of unknown water quality without adequate
disinfection before or after the system.
Organic chemicals included by surrogate testing
VOCs
(by surrogate testing using
chloroform)
Drinking water
regulatory level
(MCL/MAC) mg/L
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
alachlor
0.002
0.050
0.001
>98%
atrazine
0.003
0.100
0.003
>97%
benzene
0.005
0.081
0.001
>99%
carbofuran
0.04
0.190
0.001
>99%
carbon tetrachloride
0.005
0.078
0.0018
98%
chlorobenzene
0.1
0.077
0.001
>99%
chloropicrin
—
0.015
0.0002
99%
2,4-D
0.07
0.110
0.0017
98%
dibromochloropropane
(DBCP)
0.0002
0.052
0.00002
>99%
o-dichlorobenzene
0.6
0.080
0.001
>99%
p-dichlorobenzene
0.075
0.040
0.001
>98%
1,2-dichloroethane
0.005
0.088
0.0048
95%
1,1-dichloroethylene
0.007
0.083
0.001
>99%
cis-1,2-dichloroethylene
0.07
0.170
0.0005
>99%
trans-1,2-dichloroethylene
0.1
0.086
0.001
>99%
1,2-dichloropropane
0.005
0.080
0.001
>99%
cis-1,3-dichloropropylene
—
0.079
0.001
>99%
dinoseb
0.007
0.170
0.0002
99%
endrin
0.002
0.053
0.00059
99%
ethylbenzene
0.7
0.088
0.001
>99%
ethylene dibromide (EDB)
0.00005
0.044
0.00002
>99%
haloacetonitriles (HAN)
Bromochloroacetontrile
—
0.022
0.0005
98%
Dibromoacetontrile
—
0.024
0.0006
98%
Dichloroacetontrile
—
0.0096
0.0002
98%
Trichloroacetontrile
—
0.015
0.0003
98%
haloketones (HK)
1,1-dichloro-2-propanone
—
0.0072
0.0001
99%
1,1,1-trichloro-2-propanone
—
0.0082
0.0003
96%
heptachlor (H-34, Heptox)
0.0004
0.025
0.00001
>99%
heptachlor epoxide
0.0002
0.0107
0.0002
98%
hexachlorobutadiene
—
0.044
0.001
>98%
hexachlorocyclopentadiene 0.05
0.060
0.000002 >99%
lindane
0.0002
0.055
0.00001
>99%
methoxychlor
0.04
0.050
0.0001
>99%
pentachlorophenol
0.001
0.096
0.001
>99%
simazine
0.004
0.120
0.004
>97%
styrene
0.1
0.150
0.0005
>99%
1,1,2,2-tetrachloroethane
—
0.081
0.001
>99%
tetrachloroethylene
0.005
0.081
0.001
>99%
toluene
1
0.078
0.001
>99%
2,4,5-TP (silvex)
0.05
0.270
0.0016
99%
tribromoacetic acid
—
0.042
0.001
>98%
1,2,4-trichlorobenzene
0.07
0.160
0.0005
>99%
1,1,1-trichloroethane
0.2
0.084
0.0046
95%
1,1,2-trichloroethane
0.005
0.150
0.0005
>99%
trichloroethylene
0.005
0.180
0.0010
>99%
Trihalomethanes (THMs)
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
Bromodichloromethane
(THM)
0.080
0.300
0.015
95%
Bromoform (THM)
Chloroform (THM)
Chlorodibromomethane
(THM)
Xylenes (total)
10
0.070
0.001
>99%
Filter is only to be used
with cold water.
Filter usage must comply
with all state and local laws.
Testing was performed under
standard laboratory conditions,
actual performance may vary.
Systems certified for cyst reduction
may be used on disinfected waters
that may contain filterable cysts.
See owner’s manual for general
installation conditions and needs plus
manufacturer’s limited warranty.
• All contaminants reduced by
this filter are listed.
• Not all contaminants listed may
be present in your water.
• Filter does not remove
all contaminants that may be
present in tap water.
Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treatment Device Program.
This system has been tested according to NSF/ANSI 42, 53, 401 & P473 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, 401 & P473.
NSF/ANSI 42
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Chloramine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Particulate Reduction
85%
99.9%
Pass
NSF/ANSI 53
Required
reduction
Overall %
reduction
Results
Cyst Live Cryptosporidium & Giardia
99.95%
>99.99%
Pass
Mercury Reduction pH 8.5
<2 ug/L
>95.8%
Pass
Mercury Reduction pH 6.5
<2 ug/L
>96.5%
Pass
Lead Reduction pH 6.5
<10 ug/L
>99.4%
Pass
Lead Reduction pH 8.5
<10 ug/L
>99.3%
Pass
MTBE Reduction
<5 ug/L
86.6%
Pass
Turbidity
<0.5 NTU
99.1%
Pass
VOC Surrogate Test
95%
99.4%
Pass
Asbestos Reduction
99%
>99%
Pass
NSF/ANSI 401
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction
Results
Atenolol
30 ng/L
94.2%
94.2%
Pass
Bisphenol A
300 ng/L
98.80%
98.9%
Pass
Carbamazepine
200 ng/L
98.6%
98.6%
Pass
DEET
200 ng/L
98.7%
98.7%
Pass
Estrone
20 ng/L
96.30%
96.5%
Pass
Ibuprofen
60 ng/L
95.3%
95.4%
Pass
Linuron
20 ng/L
96.6%
96.6%
Pass
Meprobamate
60 ng/L
94.7%
94.7%
Pass
Metolachlor
200 ng/L
98.6%
98.6%
Pass
Naproxen
20 ng/L
96.3%
96.4%
Pass
Nonyl phenol
200 ng/L
97.50%
97.5%
Pass
Phenytoin
30 ng/L
95.50%
95.6%
Pass
TCEP
700 ng/L
98%
98%
Pass
TCPP
700 ng/L
97.8%
97.8%
Pass
Trimethoprim
20 ng/L
96.7%
96.7%
Pass
NSF P473
Influent
challenge
concentration
Maximum
permissible
product water
concentration
Overall %
reduction
Results
Perfluorooctanoic acid (PFOA) &
Perfluorooctane sulfonate (PFOS)
1.5 ±10% ug/L 0.07 ug/L
96%
Pass
AQ5100_PDS_20171103
Performance Data for the Aquasana Under Counter Water Filter
Model
Replacement
Operating pressure range
Rated capacity Operating temp range
Rated flow
AQ-5100
AQ-5100R
20-80 psi
1.40-5.624 kg/cm
2
200 gallons
757 liters
40-90° F
4.44-32.2° C
0.5 gpm
1.9 lpm
Manufactured by: Aquasana, Inc.
6310 Midway Road · Haltom City, Texas 76117 · 866.662.6885
NSF/ANSI 42
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available
<0.5 mg/l
96.06%
Pass
Chloramine Reduction, Free Available
<0.5 mg/l
96.06%
Pass
Particulate Reduction
85%
99.9%
Pass
NSF/ANSI 53
Required
reduction
Overall %
reduction
Results
Cyst Live Cryptosporidium & Giardia
99.95%
>99.95%
Pass
Mercury Reduction pH 8.5
<2 ug/L
>96.7%
Pass
Mercury Reduction pH 6.5
<2 ug/L
>96.6%
Pass
Lead Reduction pH 6.5
<10 ug/L
>99.3%
Pass
Lead Reduction pH 8.5
<10 ug/L
>99.4%
Pass
MTBE Reduction
<5 ug/L
91.2%
Pass
Turbidity
<0.5 NTU
99.1%
Pass
VOC Surrogate Test
95%
95%
Pass
Asbestos Reduction
99%
>99%
Pass
NSF/ANSI 401
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction
Results
Atenolol
30 ng/L
94.2%
94.2%
Pass
Bisphenol A
300 ng/L
98.80%
98.9%
Pass
Carbamazepine
200 ng/L
98.6%
98.6%
Pass
DEET
200 ng/L
98.7%
98.7%
Pass
Estrone
20 ng/L
96.30%
96.5%
Pass
Ibuprofen
60 ng/L
95.3%
95.4%
Pass
Linuron
20 ng/L
96.6%
96.6%
Pass
Meprobamate
60 ng/L
94.7%
94.7%
Pass
Metolachlor
200 ng/L
98.6%
98.6%
Pass
Naproxen
20 ng/L
96.3%
96.4%
Pass
Nonyl phenol
200 ng/L
97.50%
97.5%
Pass
Phenytoin
30 ng/L
95.50%
95.6%
Pass
TCEP
700 ng/L
98%
98%
Pass
TCPP
700 ng/L
97.8%
97.8%
Pass
Trimethoprim
20 ng/L
96.7%
96.7%
Pass
NSF P473
Influent
challenge
concentration
Maximum
permissible
product water
concentration
Overall %
reduction
Results
Perfluorooctanoic acid (PFOA) &
Perfluorooctane sulfonate (PFOS)
1.5 ±10% ug/L 0.07 ug/L
96%
Pass
System tested and certified by NSF International
against NSF/ANSI Standard 42, 53 & 401 and conforms
to NSF protocol P473 for reduction of claims specified
on the Performance Data Sheet and at www.nsf.org.
Do not use with water that is microbiologically
unsafe or of unknown water quality without adequate
disinfection before or after the system.
Organic chemicals included by surrogate testing
VOCs
(by surrogate testing using
chloroform)
Drinking water
regulatory level
(MCL/MAC) mg/L
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
alachlor
0.002
0.050
0.001
>98%
atrazine
0.003
0.100
0.003
>97%
benzene
0.005
0.081
0.001
>99%
carbofuran
0.04
0.190
0.001
>99%
carbon tetrachloride
0.005
0.078
0.0018
98%
chlorobenzene
0.1
0.077
0.001
>99%
chloropicrin
—
0.015
0.0002
99%
2,4-D
0.07
0.110
0.0017
98%
dibromochloropropane
(DBCP)
0.0002
0.052
0.00002
>99%
o-dichlorobenzene
0.6
0.080
0.001
>99%
p-dichlorobenzene
0.075
0.040
0.001
>98%
1,2-dichloroethane
0.005
0.088
0.0048
95%
1,1-dichloroethylene
0.007
0.083
0.001
>99%
cis-1,2-dichloroethylene
0.07
0.170
0.0005
>99%
trans-1,2-dichloroethylene
0.1
0.086
0.001
>99%
1,2-dichloropropane
0.005
0.080
0.001
>99%
cis-1,3-dichloropropylene
—
0.079
0.001
>99%
dinoseb
0.007
0.170
0.0002
99%
endrin
0.002
0.053
0.00059
99%
ethylbenzene
0.7
0.088
0.001
>99%
ethylene dibromide (EDB)
0.00005
0.044
0.00002
>99%
haloacetonitriles (HAN)
Bromochloroacetontrile
—
0.022
0.0005
98%
Dibromoacetontrile
—
0.024
0.0006
98%
Dichloroacetontrile
—
0.0096
0.0002
98%
Trichloroacetontrile
—
0.015
0.0003
98%
haloketones (HK)
1,1-dichloro-2-propanone
—
0.0072
0.0001
99%
1,1,1-trichloro-2-propanone
—
0.0082
0.0003
96%
heptachlor (H-34, Heptox)
0.0004
0.025
0.00001
>99%
heptachlor epoxide
0.0002
0.0107
0.0002
98%
hexachlorobutadiene
—
0.044
0.001
>98%
hexachlorocyclopentadiene 0.05
0.060
0.000002 >99%
lindane
0.0002
0.055
0.00001
>99%
methoxychlor
0.04
0.050
0.0001
>99%
pentachlorophenol
0.001
0.096
0.001
>99%
simazine
0.004
0.120
0.004
>97%
styrene
0.1
0.150
0.0005
>99%
1,1,2,2-tetrachloroethane
—
0.081
0.001
>99%
tetrachloroethylene
0.005
0.081
0.001
>99%
toluene
1
0.078
0.001
>99%
2,4,5-TP (silvex)
0.05
0.270
0.0016
99%
tribromoacetic acid
—
0.042
0.001
>98%
1,2,4-trichlorobenzene
0.07
0.160
0.0005
>99%
1,1,1-trichloroethane
0.2
0.084
0.0046
95%
1,1,2-trichloroethane
0.005
0.150
0.0005
>99%
trichloroethylene
0.005
0.180
0.0010
>99%
Trihalomethanes (THMs)
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
Bromodichloromethane
(THM)
0.080
0.300
0.015
95%
Bromoform (THM)
Chloroform (THM)
Chlorodibromomethane
(THM)
Xylenes (total)
10
0.070
0.001
>99%
Filter is only to be used
with cold water.
Filter usage must comply
with all state and local laws.
Testing was performed under
standard laboratory conditions,
actual performance may vary.
Systems certified for cyst reduction
may be used on disinfected waters
that may contain filterable cysts.
See owner’s manual for general
installation conditions and needs plus
manufacturer’s limited warranty.
• All contaminants reduced by
this filter are listed.
• Not all contaminants listed may
be present in your water.
• Filter does not remove
all contaminants that may be
present in tap water.
Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treatment Device Program.
This system has been tested according to NSF/ANSI 42, 53, 401 & P473 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, 401 & P473.
NSF/ANSI 42
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Chloramine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Particulate Reduction
85%
99.9%
Pass
NSF/ANSI 53
Required
reduction
Overall %
reduction
Results
Cyst Live Cryptosporidium & Giardia
99.95%
>99.99%
Pass
Mercury Reduction pH 8.5
<2 ug/L
>95.8%
Pass
Mercury Reduction pH 6.5
<2 ug/L
>96.5%
Pass
Lead Reduction pH 6.5
<10 ug/L
>99.4%
Pass
Lead Reduction pH 8.5
<10 ug/L
>99.3%
Pass
MTBE Reduction
<5 ug/L
86.6%
Pass
Turbidity
<0.5 NTU
99.1%
Pass
VOC Surrogate Test
95%
99.4%
Pass
Asbestos Reduction
99%
>99%
Pass
NSF/ANSI 401
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction
Results
Atenolol
30 ng/L
94.2%
94.2%
Pass
Bisphenol A
300 ng/L
98.80%
98.9%
Pass
Carbamazepine
200 ng/L
98.6%
98.6%
Pass
DEET
200 ng/L
98.7%
98.7%
Pass
Estrone
20 ng/L
96.30%
96.5%
Pass
Ibuprofen
60 ng/L
95.3%
95.4%
Pass
Linuron
20 ng/L
96.6%
96.6%
Pass
Meprobamate
60 ng/L
94.7%
94.7%
Pass
Metolachlor
200 ng/L
98.6%
98.6%
Pass
Naproxen
20 ng/L
96.3%
96.4%
Pass
Nonyl phenol
200 ng/L
97.50%
97.5%
Pass
Phenytoin
30 ng/L
95.50%
95.6%
Pass
TCEP
700 ng/L
98%
98%
Pass
TCPP
700 ng/L
97.8%
97.8%
Pass
Trimethoprim
20 ng/L
96.7%
96.7%
Pass
NSF P473
Influent
challenge
concentration
Maximum
permissible
product water
concentration
Overall %
reduction
Results
Perfluorooctanoic acid (PFOA) &
Perfluorooctane sulfonate (PFOS)
1.5 ±10% ug/L 0.07 ug/L
96%
Pass
AQ5200_PDS_20170424
Performance Data for the Aquasana Under Counter Water Filter
Model
Replacement
Operating pressure range
Rated capacity Operating temp range
Rated flow
AQ-5200
AQ-5200R
20-80 psi
1.40-5.624 kg/cm
2
500 gallons
1892 liters
40-90° F
4.44-32.2° C
0.5 gpm
1.9 lpm
Manufactured by: Aquasana, Inc.
6310 Midway Road · Haltom City, Texas 76117 · 866.662.6885
System tested and certified by NSF International
against NSF/ANSI Standard 42, 53 & 401 and conforms
to NSF protocol P473 for reduction of claims specified
on the Performance Data Sheet and at www.nsf.org.
• For conditions of use, health
claims certified by the
California Department of Public
Health, and replacement parts
see product data sheet.
• California Department of Public
Health Certification Number
13-2172