Aquapure MOP0.3-AD Скачать руководство пользователя страница 5

Medical Ozone Generator MOP0.3-AD

3

IV

Installation and Usage

1.

Take out the appliance and accessories from the package, put it on a flat ground in which space you are going to run

the appliance

2.

Connect the oxygen source to the Oxygen Input connector (O2 IN)

3.

Connect the 3 way connector to the Ozone Outlet (O3 OUT)

4.

Cut a short piece of silicon tubing, add two male luer lock connectors to each end, then connect the side outlet of 3

way connector to the Ozone Destructor (O3 Destructor

5.

Adjust the 3 way connector, make sure the gas flow is from the Ozone Outlet (O3 OUT) to the Ozone Destructor

inlet (O3 Destructor) before switch on the applicance.

6.

Connect the direct outlet of 3 way connector to the syringe or ozone bags, etc.

7.

Plug in the 12V DC power adaptor to the Mains and the appliance. The background light for “OXYGEN FLOW”

column will turn ON when the power is connected successfully.

8.

Slightly touch “POWER” on the button, the background light for the whole OZONE CONCENTRATION

CHART will turn ON. Then slightly touch I, II, or III on the button to choose the right ozone concentration and

the appliance starts working. A blue color light will be ON for indicating the ozone column that you choose.

9.

Open the oxygen source, and adjust the oxygen flow rate to get the ozone concentration according to the Ozone

Concentration Table.

10.

Adjust the 3 way connector, make the gas flow to the syringe or ozone bags, etc.

11.

After collecting the ozone, adjust the 3 way connector, make the gas flow back to the Ozone Destructor (O3

Destructor) again.

12.

Slightly touch “POWER” on the button to turn off the appliance.

13.

Close the oxygen source

14.

Unplug the appliance.

NOTE: for making ozone drinking water, it does not need the 3 way connector. Just connect the O3 OUTPUT to the

ozone glass cup inlet directly, and connect the ozone glass cup outlet to the O3 destructor.

1

12V DC power inlet

2

Power distributor board

3

Oxygen source inlet

4

Ozone outlet

5

Ozone Generating Module

6

Ozone destructor inlet

7

Ozone destructor

8

Turbo cooling Fan

9

Ozone Concentration Chart

10

Finger touch button

Содержание MOP0.3-AD

Страница 1: ...Medical Ozone Generator MOP0 3 AD 1 User s Manual MOP0 3 AD...

Страница 2: ...rator MOP0 3 AD 2 Table of Content Ozone Introduction 1 Features and Specification 1 Structure and Accessories 2 Installation and Usage 3 Application 4 Safety and Cautions 5 FAQ 6 Maintenance Service...

Страница 3: ...ating area The Only material for the ozone generating area is Pure Quartz The stain point of this pure quartz is 1110 and its soften point is 1670 This pure quartz is 100 ozone resistant an ideal mate...

Страница 4: ...ation Table Notice The ozone concentration chart numbers might be slightly different Just fefer to the chart on product itself III Structure Accessories Accessories 1pc Power Adaptor 1pc 3 way connect...

Страница 5: ...ound light for the whole OZONE CONCENTRATION CHART will turn ON Then slightly touch I II or III on the button to choose the right ozone concentration and the appliance starts working A blue color ligh...

Страница 6: ...erator MOP0 3 AD 4 V Applications Ozone Joint Injection Ozone Blood Treatment Ozone for Rectal Insufflation Gynecological ozone therapy Ozone Dental Ozone Drinking Water Ozone Ear Insufflation Ozone f...

Страница 7: ...onnect the adapter before opening the product or any maintenance 6 It is not recommended to switch on off frequently on this appliance To avoid any defective please re switch on the appliance at least...

Страница 8: ...ained or with relative knowledge of ozone appliance is allowed to operate or repair it VIII Maintenance Service 1 This Medical Ozone Generator is warranted to be free from all defects in material in n...

Отзывы: