AquaPRO TSC130 PRO Скачать руководство пользователя страница 2

7 Sp

TSC130 PRO

Para Piezas de Repuestos, Llame al 1-877-278-2797

Sírvase proporcionar la siguiente información:
- Número de modelo
- Número de serie (si tiene)
- Descripción y número de repuesto como se muestra

en la lista de repuestos

Envíe su solicitud de repuestos a la siguiente direccion:

Aqua Pro Systems
101 Production Drive
Harrison, OH  45030   U.S.A.

1

Cordón eléctrico

31006-005

1

2

Empalme de descarga

15875-002

1

3

Carcasa exterior con 
junta tórica

28053-001

1

19023-001

1

4

Impulsor

23097

1

5

Junta del espiral

23122

1

6

Cubierta del difusor con rejilla

28056-002

1

No. de
Ref.

Descripción

TSC130 PRO

CTD.

1

2

3

4

5

6

2

Operating Instructions and Parts Manual

Installation and Operation

(Continued

)

Do not handle pump with wet
hands or when standing in
water or on a damp surface when the
unit is operating or fails to operate.
Always disconnect pump power cord
from power source before handling.

6. Plug the power cord into a ground-

ed 115-volt AC power outlet. The
pump will start operating as soon as
the power cord is plugged into the
power outlet.

7. The pump will remove water down

to 1/8 inches of the hard surface the
pump was placed on.

8. The pump should be turned off

once the water level reaches the
1/8-inch mark.

Do not allow 

pump to run dry.

The shaft seal depends on water for
lubrication. Operating pump without
water will damage the shaft seal and
cause pump failure.

Maintenance

Always disconnect electric
supply before attempting to
install, service, relocate or per-
form any maintenance. Failure to do so
could result in fatal electrical shock.

Minimal service is required for this
pump. If pump should fail to operate,
perform the following troubleshooting
guidelines: 

1. The motor housing of the

pump is completely sealed
and requires no service.
Disassembly of the motor
housing or alteration of the power
cord could result in fatal electrical
shock.

2. Verify pump is operating correctly.

a. Disconnect pump from power

source.

b. Disconnect discharge hose from

pump.

c. Immerse pump in a bucket or tub

of water.

d. Plug power cord into a grounded

115 volt AC power outlet. If pump
operates correctly proceed to step
#3. If pump does NOT operate,

!

DANGER

!

NOTICE

!

DANGER

unplug power cord and proceed
to maintenance guideline item 4
in this section.

3. Verify discharge hose is correctly

installed.

a. Connect hose to another water

source such as a faucet. If water
flows through hose, proceed to
step 3b. If water is restricted, veri-
fy discharge hose is unwound.
Remove all kinks, bends or
obstructions in hose.

b. Verify pumping height does NOT

exceed 25 feet (See Figure 1). If
pumping height is greater than
25 feet, this pump will NOT work.

4. Periodic cleaning of pump is

required to maintain performance
of the pump. Follow the cleaning
steps listed below: 

a. Unplug the power cord.

b. Remove the 3 screws at the bot-

tom of the pump.

c. Remove the volute cover.

Note the alignment marks.

d. Remove the gasket. Note how the

openings in the gasket align with
the openings in the pump base.

e. Remove the debris and make sure

the impeller turns freely.

Figure 1 Water Level

25 Ft. Max.

Water Level

f. Replace the gasket making sure

the openings are aligned.

g. Replace the volute cover.

h. Replace the 3 screws.

Содержание TSC130 PRO

Страница 1: ...ger indicates an imminently haz ardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially haz ardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially haz ardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important informa tion that if not followed MAY...

Страница 2: ...aintenance Failure to do so could result in fatal electrical shock Minimal service is required for this pump If pump should fail to operate perform the following troubleshooting guidelines 1 The motor housing of the pump is completely sealed and requires no service Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock 2 Verify pump is operating cor...

Страница 3: ... Desconecte la manguera de descarga de la bomba c Sumerja la bomba en un cubo o tina con agua d Enchufe el cordón de corriente en un tomacorriente con conexión a tierra de 115 voltios CA Si la bomba funciona correctamente prosiga al punto 3 Si la bomba no funciona correctamente desenchufe el cordón eléctrico y siga las pautas de mantenimiento del punto 4 de esta sección 3 Verifique que la manguera...

Страница 4: ...ualquier daño que pueda haber ocurrido durante el envío Revise si hay partes dañadas faltantes o sueltas Peligro indicauna situación inminentemente peligrosa que si no se evita dará como resultado la muerte o lesiones graves Advertencia indica una situación potencialmente peligrosa que si no se evita podría dar como resultado la muerte o lesiones graves Precaución indica una situación potencialmen...

Отзывы: