Installation
Guidelines

(Continued)

Do not glue the 
blower to the

supply line. Glue fumes can potentially
cause an explosion when the blower
starts. Install a 1/4” self-tapping screw
to secure the joint if necessary.

Do not install 
blower below

water level. Blower must be at least
one foot above the maximum water
level.

4. Mount blower in a vertical position

using vertical rigid PVC pipe as 
shown in Figure 1.  For additional 
support use supplied bracket as 
shown in Figure 1. For warm 
climates, try to locate the blower in
a shaded location.

If the blower is to 
be installed more

than 25 ft from the spa, it will be
necessary to install a loop that is 1
foot above the water line and as close
to the spa as possible (See Figure 1).

A loop and a check 
valve must be

installed at least one foot above the
water level when supercharging water
jets.

5. Verify plumbing is free of leaks 

before adding water to spa.

6. Do NOT install adjustable jets. 

Adjustable jets can cause excessive 
back pressure within the unit.

7. Hydrotherapy jets naturally aerate 

when installed correctly. Do not use
blower to supplement aeration 
when jets have been installed 
incorrectly.

Wiring Guidelines

Failure to observe 
wiring instructions,

could result in death or serious injury.

All wiring 
and electrical

connections must be performed by a
qualified electrician. Installations must
be in accordance with local and
national codes.

1. For electrical ratings, see product 

decal.

2. Check the line voltage to make 

certain it is correct for the blower 
being used.  Do not attempt to
connect 240 VAC to a 120-volt
blower; it will damage the blower
and void the warranty.

2

3. Refer to the National Electric Code 

Guidelines for wire size and to 
prevent electric shock.

4. Refer to the National Electric Code 

Guidelines for proper selection of 
wiring conduit and strain relief.

5. The blower field-wiring box is 

designed for non-metallic electrical 
tubing only.  Refer to the National 
Electric Code Guidelines for proper 
selection of wiring, and strain 
relief.  

6.

Be certain to connect the green 
ground wire supplied with the 
blower to the ground from 
your electrical panel.

7. Connect remaining line wires 

individually to the remaining wires 
in the blower.

8. When wiring is complete carefully 

install gasket and conduit cover 
plate.

Overheating, short- 
circuiting and fire

damage will result from inadequate
wiring.

www.aquaprosystems.com

Figure 1

877.278.2797

Operating Instructions and Parts Manual

Grade

Wall or post

Bracket

Rigid PVC pipe

Check valve
(location when
NOT using a
Hartford Loop)

Air flow

5 Foot minimum from water
(use non-metallic plumbing)

Orient blower
housing as shown

Conduit box and cover

Non-metallic
electrical tubing

24 inches above
surrounding
grade / 12 inch
minimum above
water

Mount using rigid PVC pipe. For additional support, use supplied bracket as shown.

Hartford Loop required if Blower is more
than 25 feet away from pool / spa

12 inch minimum

Alternate location for check valve if
Harford Loop is used

3

Blower Sizing

The number of holes in the seats and
floor of the spa can be used to
determine the size of the air blower
that will be required for your
application. See Chart 1 for
recommended blower size based on
the number and size of holes.

Water Jet
Applications

The blower can be used to boost the
output of hydrotherapy jets. A venturi
fitting is normally incorporated into
the jet design. The purpose of the
fitting is to allow air to mix with the
water in the jet. The venturi fittings
can be connected together and then
pressurized with air from the blower to
greatly increase the jet action.

www.aquaprosystems.com

New Spa
Applications

It is important to select a water pump
that will supply sufficient flow to the
jets. Consult with the jet manufacturer
for assistance in selecting a pump or
pumps that will accommodate the
number of jets desired in the spa.
Improper sizing can cause overheating
of the pump and blower.

Choose the correct size blower based
on the number of water jets in your
spa (see Chart 1). See the chart below.
Refer to  the installation guidelines for
additional details. 

Winterizing

The blower is designed for outdoor
use. There are no special off-season
requirements for the blower.  In some
spa systems it is possible to protect
discharge lines from freezing by
operating the blower for several
minutes with the spa drained. The
airflow can be used to purge water
from the air lines.

877.278.2797

Chart 1

Notes

PRO1002403, PRO1502403, PRO2002403,

PRO100120, PRO150120, and PRO200120

Recommended Number of Holes 

at the Following Hole Diameters

1/8 Inch

3/16 Inch

1/4 Inch

76

35

20

100

46

26

150

68

38

Total Hole Area

Square Inches

1.0

1.4

1.8

Blower

Model

PRO100120, PRO1002403

PRO150120, PRO1502403

PRO200120, PRO2002403

Number of

Water Jets

4 to 9

9 to 13

14 or more

Содержание PRO100120

Страница 1: ...tract warranty tort including negligence or otherwise shall AquaPRO or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to associated equipment cost of capital cost of substitute products facilities services or replacement power downtime costs or c...

Страница 2: ...1 7 Discharge Housing 28555 001 1 8 8 16 x 3 4 inch Plastite Screw 67007 001 8 9 Check Valve 10116 001 1 Ref No Description Parts Number QTY For Replacement Parts call 1 877 278 2797 Replacement Parts List 1 Please provide following information Model number Serial number if any Part descriptions and number as shown in parts list 2 3 4 5 8 9 PRO1002403 PRO1502403 PRO2002403 PRO100120 PRO150120 and ...

Страница 3: ...d always be followed READ AND FOLLOW ALL INSTRUCTIONS Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury...

Страница 4: ...ting short circuiting and fire damage will result from inadequate wiring www aquaprosystems com Figure 1 877 278 2797 Operating Instructions and Parts Manual Grade Wall or post Bracket Rigid PVC pipe Check valve location when NOT using a Hartford Loop Air flow 5 Foot minimum from water use non metallic plumbing Orient blower housing as shown Conduit box and cover Non metallic electrical tubing 24 ...

Отзывы: