AQUAPHOR RO-70S Скачать руководство пользователя страница 5

5

AQUAPHOR RO-70S | Owner’s manual

• 

At an effort of 8–10 kgf, the tube should not be able to be pulled out.

• 

Set the input valve to the position 

Closed

.

• 

Open the water from the main line. 

Important! Make sure that the sealing pad was on its own place 

and was not damaged during installation of the connection node.

Installation of the faucet for clean water* (fig. 4)

• 

Drill a 12 mm hole in the sink (countertop).

• 

Put the decorative stand (2), the rubber gasket (3), the rubber washer 

(4) on the threaded shank (1) of the faucet and insert the tap into the 

wash hole.

• 

Place the plastic washer (5), the metal lock washer (6) on the threaded 

shank from the bottom of the countertop and screw the fastening nut 

(7).

• 

Insert the tube (9) into the threaded shank of the tap (1) with the end 

of the pressed metal sleeve and tighten the union nut (8) until it 

stops;

• 

Check the strength of the tube (9). The tube should not be able to be 

pulled out when using a force of 8–10 kgf. 

Attention! We recommend that you use the clean water faucet 

included with this product. The use of other faucets can lead to vibrations and other extraneous 

sounds.

Drain saddle installation (fig. 5)

•  It is the best install the drain saddle on the sink 

drain  before  the  siphon  trap  or  bend  (the  drain 

saddle on most drain pipes is of ~40 mm diameter). 

• 

Remove the protective film (2) from the gasket (1). 

Glue  (or  fasten)  the  sealing  gasket  (1)  from  the 

inside of the clamp so that the hole in the gasket 

matches the hole in the saddle union.

•  Install the saddle on the drain line and then tighten 

the bolts (3). Bolts should be tightened evenly, so 

that the two parts of the yoke are parallel.

• 

Drill  a  hole  7  mm  in  diameter  through  the  hose 

connection.

• 

On the JG drain tube, put on the plastic nut and, 

inserting the tube into the drainage collar, screw the nut onto the nipple.

Installing the crevice insert** (fig. 6)

•  Remove the crevice insert, which is under the cover of the water 

purifier. In order to remove the cover, it is necessary to turn the 

three latches counter-clockwise.

• 

Insert the crevice insert into the 3/8” (9.5 mm) tube as shown in 

fig. 6 and connect this end of the tube to the water cleaner.

Attention! The kit includes three inserts: one for the 

installation, two are spares.

*  The manufacturer reserves the right to use the connection points and 

faucet of a similar design. If necessary, contact the after-sales service.

** The crevice insert is installed only for the water with a high content of 

mechanical impurities in the water.

6

5

3

4

2

1

Figure 4

Figure 5

Figure 6

Crevice 

insert

Содержание RO-70S

Страница 1: ...removes heavy metals Carbon block with АQUALEN completely removes chlorine organic substances and carcinogens STC Safe To Consume Materials are certified for contact with drinking water and food Absorbs free radicals DWAY DOUBLE WAY is a unique technology of water conditioning and optimization pH and microelements balance Сlick Turn Easy cartridge replacement Clear and safe maintenance AQUAPHOR RO...

Страница 2: ...the reverse osmosis membrane at a water temperature of 25 C 80 F and a pressure of 0 4 MPa 76 psi for the membrane 50 gal day 7 6 liters per hour for the membrane 100 gal day 15 2 liters per hour The ratio of purified water and water entering the drainage at a water temperature of at least 20 C 70 F 1 4 1 6 Weight not more than 6 2 kg 14 pounds 3 PRODUCT ASSEMBLY No Description Qty 1 RO 70S housin...

Страница 3: ...verse osmosis membrane RO 50S The block of reverse osmosis membrane cleans water from organic and inorganic compounds salts and also softens water 4 The water conditioning unit 4 includes a post filtration cartridge or a water conditioning cartridge Aquaphor hereinafter post filter depending on the RO 70S version The water conditioning unit removes extraneous smell and taste and depending on the p...

Страница 4: ...RO 70S should be distanced or isolated from heat sources cookers boilers hot water pipes dishwashers or washing machines etc Installation of the connection node fig 3 Shut off the cold water Open the kitchen faucet to relieve pressure in the water supply Connect the cold water supply water connection Connect the red JG tube For this pull out from under the plastic bushing stopper clip insert the p...

Страница 5: ...all the drain saddle on the sink drain before the siphon trap or bend the drain saddle on most drain pipes is of 40 mm diameter Remove the protective film 2 from the gasket 1 Glue or fasten the sealing gasket 1 from the inside of the clamp so that the hole in the gasket matches the hole in the saddle union Install the saddle on the drain line and then tighten the bolts 3 Bolts should be tightened ...

Страница 6: ...the locking clip 2 out from under the plastic sleeve 1 insert the pre wetted end of the tube 3 into the sleeve bushing to a depth of approximately 15 mm to the stop and install the clip 2 into place Check the strength of the tube 3 at an effort of 8 10 kg the tube should not be able to be pulled out Pull the locking clip 2 out from under the plastic sleeve 1 and pull the tube 3 by pressing the end...

Страница 7: ...n The type of cartridge BLACK RED K3 Membrane cartridge Step 4 Rinse the RO 70S Rinsing of reverse osmosis membrane unit Set the input tap on the connection node to the Open position Open the faucet for fresh water Wait for water to flow from it Run water through the RO 70S for 1 hour Close the fresh water faucet Flush the storage tank After filling the storage tank when the water stops coming out...

Страница 8: ...propriate manifold as far as it will go and slightly pressing upwards turn the cartridge clockwise until it clicks Set the input tap to the Open position and make sure that the RO 70S is sealed Perform the procedure Rinsing the reverse osmosis membrane unit see p 8 Replacing the conditioning cartridge fig 12 Set the shutoff valve on the connection node to the Closed position then open the fresh wa...

Страница 9: ...on its own This work should be carried out by a specialist authorized to carry out this type of work The manufacturer is not responsible for the inadequate quality of the connection of the RO 70S to the water supply network as well as for the result of this work Responsibility for the shortcomings of this work as well as for causing harm to the health or property of the consumer or other persons d...

Страница 10: ...oss resulting from sediment or foreign matter contained in a water system Damage or loss resulting from negligent or improperinstallation including installation of a unit in a harsh or hazardous environment Damage or loss resulting from removal improper repair modification of the product or improper maintenance including damage caused by chlorine or chlorine related products Damage or loss resulti...

Страница 11: ...inary water preparation unit K3 Replace the crevice insert or wash previously installed under a stream of cold water Replace the KO 50 membrane module Replace the water conditioning module Contact the after sales service Open the connection node tap Install a booster pump for the whole home or specifically for the RO 70S Contact the after sales service Replace the water conditioning module Contact...

Страница 12: ...ried out Name of the company which carried out installation Name of the service engineer Service engineer s signature Client s signature For installation operational and technical maintenance please contact AQUAPHOR RO 70S Drinking water machine Aquaphor DWM 701 12FM S4 Manufacturer Westaqua Invest OU division of Aquaphor Corp L Tolstoi 2A Sillamäe Estonia 40231 www aquaphor com Serial date of man...