background image

22 

 

 

 

 

10/9/2013  

               Drinking Water Machine

Installation Guide

Drinking Water Machine  

 

 

10/9/2013   

 

 

                23

Installation Guide

Air Gap Spigot Assembly (Lead Free)

Figure 16: Air Gap Spigot Assembly (Lead Free)* (treated water spigot)

Part #

Description

Quantity

10005

Air Gap Spigot Assembly (Lead Free)

1

DWM Assembly

Figure 17: DWM Assembly

Part #

Description

Quantity

1

10015

Input/Output Valve assembly

1

2

10020

Valve Assembly

1

Assembly and Parts, Cont.

Assembly and Parts, Cont.

Содержание DWM-101

Страница 1: ...ing Water Machine AQUAPHOR DWM 101 System Tested and certified by NSF International against NSF ANSI Standard 58 for the reduction of claims specified on performance data sheet INSTALLATION GUIDE VERSION 1 2 ...

Страница 2: ... iron algae sulphur tannins organic matter or other unusual substances then unless the appliance is represented as being capable of handling these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise AQUAPHOR shall have no obligations under this warranty This warranty does not cover d...

Страница 3: ...coming water pressure and the water temperature This appliance is designed with a self regulating flush feature that limits the reject water to approximately 5 gallons 19 L for every gallon liter of treated water Your appliance will perform better and last longer with heavy use We encourage you to water house plants provide water for pets cook mix drinks fill batteries etc with treated water Cauti...

Страница 4: ...e for convenient use 6 Appliance Shutoff Valve Consists of the supply line to the spigot blue supply line to the appliance and the incoming water supply line Turn this lever to shut off the water to the appliance from the incoming water supply 7 DWM Assembly The DWM assembly contains a decorative cover that is attached by three plastic fasteners four twist lock fittings for attaching the replaceab...

Страница 5: ... this checklist before installation The Drinking Water Machine is designed to be used for the treatment of municipally treated water or pre treated well water A water softener or additional types of pretreatment are highly recommended should your water not meet water quality or characteristics standards Water Quality If the water supply contains bacterial iron algae sulphur tannins organic matter ...

Страница 6: ...ee Figure 1 before proceeding to familiarize yourself with the general layout of the appliance Step 2 Check Fit Ensure that the complete appliance will fit in the installation location before proceeding Check all factory fittings and tubing connections Be sure all locking clips are in place See steps A through F below for tube connection instructions A Cut the tube square It is essential that the ...

Страница 7: ...elain or enamel E Use the pilot hole as a guide to drill a 1 inch diameter hole with carbide bits to mount the spigot Step 4 Prepare the Air Gap Spigot Assembly for Installation A Assemble the spigot with all of the components See Figure 16 according to the spigot assembly instructions included with the spigot B Feed the assembled spigot and tubing through the hole in the sink and fasten from unde...

Страница 8: ...e the flanges with tap water Caution Do not touch the filter s with your bare hands Peel the wrapper and use as a sleeve to prevent contamination Lubricate O Rings with glycerin Never use a petroleum based lubricant where it can contact the O Rings D Install the cartridges in the Rinsing position according to the numbered locking buttons located on the sides of the manifolds See Table 1 E Insert c...

Страница 9: ...tart Up Procedures Cont Installation Steps and Start Up Procedures Cont Figure 11 Incoming Water Supply Valve Figure 12 Unscrew the Cover of the Membrane Cartridge F Repeat steps E five 5 more times G After the storage tank is filled up for the seventh time the water is now ready to use Important To maintain the highest quality of water AQUAPHOR recommends that if the treated water is not used for...

Страница 10: ...ace any clogged cartridges See Changing the Filter Cartridges 1 2 and 4 J Replace any filter cartridge or RO Membrane 3 as deemed fouled after the testing process Turn on the incoming water valve to the appliance K Turn on the treated water spigot and verify flow of water If the water flow is still reduced repeat steps C J to determine if a second cartridge is clogged If water flow is normal proce...

Страница 11: ... tank with the Tank Flange Key 4 Examine the membrane neck for damage and inspect and or replace the O Ring 5 Lubricate the O Ring and storage bladder neck with glycerin before re installing the tank flange 6 Reconnect the blue tube to the water fitting at top center of the storage tank and reinstall the I O Valve assembly C Ensure there are no leaks and then replace the decorative cover Unusual S...

Страница 12: ... Assembly Lead Free Figure 16 Air Gap Spigot Assembly Lead Free treated water spigot Part Description Quantity 10005 Air Gap Spigot Assembly Lead Free 1 DWM Assembly Figure 17 DWM Assembly Part Description Quantity 1 10015 Input Output Valve assembly 1 2 10020 Valve Assembly 1 Assembly and Parts Cont Assembly and Parts Cont ...

Страница 13: ...ct the tube from the drain saddle and clean out the debris or replace the drain line Broken handle or spout Fatigue or misuse Replace the spigot assembly Unusual sounds during operation Problem with one of the restrictors See Maintenance Procedures Troubleshooting Model Part AQUAPHOR DWM 101 RO Membrane 3 TFC ULP Production Rates Gallons per day1 Liters per day1 NSF gpd2 NSF lpd2 52 5 198 36 87 13...

Страница 14: ...26 10 9 2013 Drinking Water Machine Installation Guide Drinking Water Machine 10 9 2013 27 Installation Guide Notes Notes ...

Страница 15: ...P O Box 298 Groveport OH 43125 Phone 614 836 9422 Fax 614 836 9876 2013 Drinking Water Machine AQUAPHOR DWM 101 ...