SETUP 09: FEED FLOW ‘K’
Setting the number of pulses per liter.
Note: the parameters are set by flowmeter manufacturer.
RECOVERY SETUPS (SETUP-10-13)
The table below represents the values required for the specific recovery percentage. The setups should be performed
under 20
°C
and conductivity <2000 uSM.
It is recommended to start setting up with the change of Flush Pulse Duration value (Setup 11). By changing the val-
ues of Setups10
–
13, the user will gradually get the desired recovery percentage.
SET-10
SET-11
SET-12
SET-13
Recovery
%
Flush pulse/min
Flush pulse
duration (s)
Periodic flush/hour
Periodic flush
duration (s)
50
2
10
20
15
55
3
5
12
15
60
3
4
12
10
65
2
5
12
10
70
2
4
12
10
75
1
2
20
15
80
1
3
6
10
85
1
1
20
10
90
1
1
10
8
SETUP 10: FLUSH PULSE/MIN
Setting the number of pulses per minute.
SETUP 11: FLUSH PULSE DURATION
Setting the number of periodic flushing pulse duration.
Содержание APRO 1000 LPH
Страница 1: ...aquaphor pro com TP APRO WH R02 APRO WH 1000 LPH WATER PURIFICATION SYSTEM...
Страница 8: ...8 aquaphor pro com TP APRO WH R03 2 SYSTEM OVERVIEW APRO WH 1000 LPH system dimensions...
Страница 9: ...9 aquaphor pro com TP APRO WH R03...
Страница 13: ...13 aquaphor pro com TP APRO WH R03 3 2 ELECTRIC CIRCUIT SCHEMES...
Страница 14: ...14 aquaphor pro com TP APRO WH R03...
Страница 15: ...15 aquaphor pro com TP APRO WH R03...
Страница 16: ...16 aquaphor pro com TP APRO WH R03...
Страница 17: ...17 aquaphor pro com TP APRO WH R03...
Страница 18: ...18 aquaphor pro com TP APRO WH R03...
Страница 19: ...19 aquaphor pro com TP APRO WH R03...
Страница 20: ...20 aquaphor pro com TP APRO WH R03...
Страница 80: ...80 14 ADDITIONAL MATERIALS...
Страница 81: ...81...
Страница 83: ...83 REMARKS...