AquaMedic Kauderni CF Скачать руководство пользователя страница 8

 
 

 

 

Fig. 3: Bushing or tank fitting 

(the glass pane is placed between slide ring 3 and rubber ring 2) 

 
1.

 

Thread 

2.

 

Rubber sealing 

3.

 

Slide ring 

4.

 

Nut 

 
There is a blue fitting in the mounted bend of the return line. Here, air is sucked in when the pump in the cabinet 
fails. This prevents the formation of communicating pipes and an overflow of the filter tank by returning water.  
 

When starting the aquarium, water has to be filled in until the filter tank is filled up to 10 – 12 cm in the front 
part and then the pump has to be started. If the water level in the filter tank decreases, water has to be filled 
in until the a.-m. maximum is reached. Take care that enough space is left so that the inflowing water in case 
of failure or shutdown of the circulation pump still fits into the filter tank. The cables of circulation pumps or 
other parts mounted in the aquarium can be routed through the empty conduit downwards. If a plug is too big 
for  this,  the  profile  slid  onto  the  rear panel  can  be cut  with  a  PUK  saw  so  that  cables  can  be  led  out of  the 
aquarium  at  the  back.  The  back  side  should,  however,  remain  closed  to  allow  the  fan  to  suck  in  air  in  the 
aquarium and not from the outside. 

 
3.  

Skimmer EVO 500 

 

See separate manual. The skimmer is hooked to the rear wall of the filter sump with the holding unit without 
screws (refer to Fig. 2).  
 

4.  

Lighting aquarius 60 (please refer to the attached manual)

  

 

 

 
Fig. 4: Holder for aquarius 
 

 

Take care that no humidity and no salt enters the interior of the lighting system! 
 
 

Содержание Kauderni CF

Страница 1: ...on manual Please read the manual carefully before use P 6 9 F Mode d emploi Veuillez lire soigneusement les instructions d avant utilisation P 10 13 Produkt Info AB Aqua Medic GmbH Gewerbepark 24 4914...

Страница 2: ...C Runner 2 2 siehe gesonderte Anleitung Nicht im Lieferumfang enthalten sind ein Heizstab sowie eine Zeitschaltuhr und eine Steckdosenleiste Die Leistung des ben tigten Heizstabes richtet sich nach de...

Страница 3: ...ch den Not berlauf zum Filterbecken In solch einem Fall ist der Kugelhahn weiter zu ffnen oder eine etwaige Verstopfung zu beseitigen Produziert der berlauf laute Ger usche muss der Hahn weiter geschl...

Страница 4: ...f llt man dieses zun chst solange mit Wasser bis das Filterbecken im vorderen Teil 10 12 cm hoch mit Wasser gef llt ist und startet dann die F rderpumpe Sinkt der Wasserstand im Filterbecken ab f llt...

Страница 5: ...aufdatum auf alle Material und Verarbeitungsfehler des Ger tes Auf die Dichtigkeit des Beckens gew hren wir eine Garantie von drei Jahren Im brigen stehen dem Verbraucher die gesetzlichen Rechte zu di...

Страница 6: ...lation pump DC Runner 2 2 see separate manual Not included are a heater stick a timer and a socket board The power of the required heater stick depends on the temperature of the aquarium environment I...

Страница 7: ...o be eliminated If the overflow makes loud noises the ball valve has to be closed a bit more so the water is bottled up stronger so that no air is dragged along At least in the initial phase this has...

Страница 8: ...t enough space is left so that the inflowing water in case of failure or shutdown of the circulation pump still fits into the filter tank The cables of circulation pumps or other parts mounted in the...

Страница 9: ...defects of the device A 36 month guarantee is granted on the tightness of the tank Incidentally the consumer has legal rights these are not limited by this warranty This warranty does not cover user...

Страница 10: ...ion s par e Ne sont pas inclus un chauffage une minuterie et une rampe de prises lectriques La puissance du chauffage d pend de la temp rature ambiante dans laquelle se trouve l aquarium Si l aquarium...

Страница 11: ...ner un ventuel bouchon Si l coulement est bruyant il faut fermer le robinet davantage afin que le stockage de l eau augmente pour que de l air ne puisse tre entra n Il faut contr ler r guli rement cet...

Страница 12: ...dans le bac de filtration on proc de au remplissage jusqu au niveau maximum Il faut qu il reste assez de place afin que lors de la d fection ou de l arr t de la pompe il reste assez de place pour l e...

Страница 13: ...de la date d achat contre tout d faut mat riel ou de fabrication Nous garantissons l tanch it du bac durant 3 ans Le consommateur b n ficie par ailleurs des droits l gaux celles ci ne sont pas limit...

Отзывы: