Hydrocell Pre-2006   

2 DIL & 4 DIL Common 
Set Up 

1.  Connect your CR-P2 battery to either Battery Connector terminal.  
2.  To enter test mode; Flick DIL switch No1 into the ON position (UP) 

and back OFF (DOWN).   

3.  The solenoid valve will briefly click open and close. After 20 seconds 

the  unit  will  enter  test  mode  and  the  Hydrocell  will  detect        
movement.  Upon  detection,  the  valve  will  briefly  click  open  and 
close, this will continue on detection.  

4.  If the cistern is empty jump to 

Stage  5

. If the cistern is 

not

 empty 

follow this procedure: 

Press and release the fill button, this will 

open  the  valve  and  allow  water  into  the  cistern.  When  the 

cistern  begins  flushing,  press  the  fill  button  to  close  the 
valve.    The  cistern  will  now  be  empty.  Flick  DIL  switch  No1 

into the ON position (UP) and back OFF (DOWN) and wait for 
5 seconds. 

 

5.  Press and release the fill button, this will open the valve and allow 

water  to  flow  into  the  cistern.  When  the  cistern  begins  flushing, 

press and release the fill button to close the valve.  

 

                                                                                C o n t i n u e d .

 

 

 

 

 

Battery  
connector 

DIL Switch 

Fill Button 

Battery  
connector 