15
18
Pass the hose through the gel hook.
Fixed Harmony head installation
1
Prepare pipework from the shower valve to the required position for the fixed shower
head using a Ø15mm copper pipe. Slide the wall spacer down the projecting pipe flush
with the finished wall surface.
2
Slide the 15mm gripper ring down the projecting pipe flush with the wall spacer fitting.
3
Trim the projecting pipe to a length of 20-50mm, measured from the front face of the grip ring, using a
rotary type cutter. If a hacksaw is used, the pipe end must be carefully de-burred and chamfered.
4
Clean and lubricate the pipe using a suitable (silicone based) lubricant.
5
Carefully side the fixed head cover plate down the fixed head arm taking care not to damage the plating.
6
Offer the fixed head arm into position over the pipework assembly and mark and
prepare the fixing points using the fixings provided, if suitable.
19
Ensuring the hose washers are in the correct position, depress the anti-swivel locking
button on the handset and secure the handset to the hose. Connect the hose to the
outlet connection and place the handset into the handset holder.
Dream installation guide:Dolphin install Guide 18/1/11 09:52 Page 15