Aquagarden Mako 1000 Скачать руководство пользователя страница 2

General Safety Instructions

1.  Only use this pump with the voltages specified on the pump label.
2.  Disconnect the mains supply before handling the pump in any way. 
3.  Never operate the pump when people are in contact with the water. 
4.  Never carry, lift, lower or pull the pump by the cable. 

Features

1. Precise high aluminum ceramic shaft for fresh and sea water dual use.
2. Double water-cooled structure for rapid heat dissipation.
3. Adopts high quality resin to seal the winding and never leak electricity.
4. Super quality ABS plastic housing, which is anticorrosive and anti-striking.
5. Can be operated submersible or in-line.

Functions   

 1. It is used for supplying and draining fresh/sea water.

 2. It is used for water supplying and draining for sea fish breeding pond.

3. It is used for wave-making for aquarium, garden watering, water supplying and circulating for rockery, 
fountain, landscape, water cleaning and draining for under-ground pond.

Mounting Instructions

If the submersible pump will be used inside water, place the pump with front cover, filter sponge and filter 
case and water outlet adapter in desired place, position suction cups on pump and attach to aquarium or 
other place before connecting power source. Do not put the plug together with the pump into water. If the 
plug drops into water, power supply should be turned off immediately so as to avoid electric shock. If the 
pump will be used outside water, mount it with water intake, outlet adapters & pipe on a flat and solid base. 
Remove the power supply cord from socket before doing any maintenance or cleaning work. The pump can 
be used in doors. The power supply cord cannot be changed or replaced. It must not be bent or used to carry 
the pump. If the cord is damaged, do not use the pump.

Operational Instructions

During Operation
If clogging of the filter cover inlet occurs, shut off the power immediately.
If the pump does not operate as it should after cleaning, please consult your local Aquagarden stockist to 
establish the cause of the problem.
If freezing temperatures are forecast, switch off the pump, remove it from the water and store it after cleaning 
and drying the impeller chamber completely.
After periods of inoperation
If the pump is left submerged in pond water for a long period of time without operation, it could lead to the 
accumulation of debris inside the pump.  Clean the pump and run it in clean water for a few minutes before 
returning the pump to the pond.

Electrical Safety Instructions

1.  Always operate the pump at voltages between 220 & 240 volts. 
2.  For outdoor use, the plug must be connected to a weatherproof socket. 
3.   The electricity supply circuit must be fitted with a suitable fuse or a Residual Current Device (RCD), also 

known as a Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30 mA. 

4.   It is necessary to conform to the regulations of the local electricity authority that may require additional 

cable protection. There may also be building regulations covering the installation of pumps and ponds. 

5.   The electrical cable is permanently connected and sealed into the pump. Should the cable become 

damaged, it cannot be repaired or replaced and the pump should be discarded. 

General Maintenace & Cleaning

While the water chamber has a very effective self cleaning feature, any apparent reduction in the water 
flow rate from your pump usually indicates that it requires cleaning. Regular cleaning and maintenance will 
significantly lengthen the life of the impeller and the motor unit. 
To clean your pump: 
1.   First disconnect it from the mains supply and press in the two sides of the water inlet cover to remove it 

from the water chamber housing.

2.   Now undo the 4 screws that connect the water chamber housing to the motor body and remove the 

water chamber to reveal the impeller.

3.   Remove and check the impeller and rotor for dirt and grime and clean all parts in clean water. Do not use 

hard objects, aggressive cleaning agents, or high-pressure machines. 

4.   Rinse all parts thoroughly in clean water and reassemble and reinstall your pump following the Installation 

Instructions above. 

Performance Curve

Performance Chart

MODEL

1000

1500

2500

4000

6000 9000

1000LV 1500LV 2500LV

Power

12W

20W

35W

100W

150W

240W

19W

30W

44W

Max Flow

1050L/h

1400L/h

2400L/h

4100L/h

5800L/h 9000L/h

1050L/h

1400L/h

2400L/h

Max Head

1.4m

1.8m

2.15m

2.7m

9.5m

5.80m

1.4m

1.8m

2.15m

Cable length

10m

10m

10m

10m

10m

10m

10m

10m

10m

A guide to simple problem solving

If you encounter a problem with this pump, before returning it to your Aquagarden stockist please check the 
following chart for a possible cause and solution to your problem.

SYMPTOM

PROBABLE CAUSES

COUNTERMEASURE

The pump does not run

Power is not turned on

Turn on the power

Improperly plugged in

Push the plug fully into the socket

Blocked impeller

Unplug the pump and remove foreign 
matter from impeller

The motor turns on and 
off repeatedly without the 
pump running, or the motor 
suddenly stops and cannot be 
started again

The water inlet or outlet pipe is 
clogged with debris

Unplug the pump and remove foreign 
matter from the pipes

The pump runs normally to 
start with but the water flow 
reduces or there is no water 
flow at all

Impeller is worn out and needs 
replacing

Replace the impeller with a new one 
from your Aquagarden stockist

The water level in the pond is too low, 
exposing the pump to the air

Ensure that the pump is fully 
submerged under water and, if 
necessary, top up the pond

A hose is too long or clogged with 
debris

Shorten the hose and / or clear the 
blockage

There is air in the impeller chamber 
(only applicable when the pump is 
located out of water)

To remove the air, submerge the pump 
under water and switch ON and OFF 
two or three times

MAX HEAD HEIGHT

FLOW L/H

4000

6000

9000

0          1000        2000        3000       4000         5000        6000       7000        8000        9000

6.0m

5.0m

4.0m

3.0m

2.0m

1.0m

0

1000

1500

2500

 

 

MODEL 

 

 

1000  

1500  

2500  

4000  

6000  

9000

Power 

 

12W 

20W 

35W 

100W 

150W 

240W

Max Flow 

 

1050L/h  1400L/h  2400L/h  4100L/h  5800L/h  9000L/h

Max Head 

 

1.40m 

1.80m 

2.15m 

2.70m 

4.20m 

5.80m

Cable length 

 

10m 

10m 

10m 

10m 

10m 

10m

PERFORMANCE

 

CHART

PERFORMANCE CURVES

Отзывы: